• Title/Summary/Keyword: Outflow rate

Search Result 275, Processing Time 0.022 seconds

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

Seasonal characteristics of thermal and chemical stratification in Lake Paldang (팔당호의 계절별 열적 및 화학적 층화 특성)

  • Son, Ju Yeon;Park, Jin Rak;Noh, Hye Ran;Yu, Soon Ju;Im, Jong Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study was to investigate the thermal and chemical stratification in Lake Paldang 2013-2018 weekly using Schmidt's stability index (SSI) and the index of chemical stratification (IC-i). The annual average for SSI was 19.1 g cm/㎠ with the maximum value of 45.3 g cm/㎠ in the summer and the minimum value of 4.8 g cm/㎠ in fall-winter showing seasonal differences as well as increased vertical mixing in the summer. The lake stability increased higher in 2016 as compared with the other period. The most influential factors of thermal stratification were temperature and heavy rainfall. Especially, high water temperature and a prolonged residence duration caused by reduced rainfall and inflows could result in an increase of the stratification period. While decreasing inflow and outflow at the end of the rainfall, the thermal stratification was restrengthened within 7-14 days, and then stabilized rapidly before the rainfall. IC-DO increased with high air temperature in the spring and fall-winter. However increasing sunshine duration and residence time and decreasing rate of outflow caused an increase of IC-DO in the summer. Rainfall (less than 800 mm/year) and discharge (less than 200 CMS) significantly declined in 2015 resulting in IC-DO (0.77) increased more than three times over the other years and bottom water hypoxia occurred. The SSI and IC-i used in this study could be applied to other lakes to understand changes in stratification and mixing dynamics.

An Efficient Method for Zircon Separation Using the Gold Pan (선광팬을 이용한 효과적인 저어콘 분리법)

  • Cheong, Wonseok;Cho, Moonsup;Kim, Yoonsup
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.63-70
    • /
    • 2013
  • We report an easy and efficient method for separating zircon grains using a gold pan and disposable sieve together with the tap water. Samples powdered to less than $230{\mu}m$ in grain size are placed on the water-filled pan tilted at about $10^{\circ}$. The outflowing water flooded with low-density particles is screened by a ${\sim}70{\mu}m$ sieve. The most efficient rate of water outflow is estimated to be 0.1 L/sec, when the distance between the tap and the surface of water-filled pan is kept at 20-25 cm. After 20-30 minutes of water outflow, heavy mineral fractions are ready for zircon collection using a hand magnet (and heavy liquid when necessary) or simply hand-picking. This procedure is most likely applicable for the separation of other heavy minerals including monazite.

Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger (지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석)

  • Gil, Hu-Jeong;Lee, Kang-Ja;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation (수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Kim, Ju-Young;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves (송아지에 이식한 공기구동형 인공심장의 혈역학적 연구)

  • 박표원
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

Comparison of Degradation due to Fenton Reaction between Reinforced and Non-reinforced Membranes Used in PEMFC (PEMFC에 사용되는 강화막과 비강화막의 Fenton 반응에 의한 열화 비교)

  • Oh, Sohyeong;Yoo, Donggeun;Lee, Mihwa;Park, Jisang;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.508-513
    • /
    • 2021
  • In order to improve the durability of a proton exchange membrane fuel cells (PEMFC), it is essential to improve the durability of the polymer membrane. In order to improve the durability of the membrane, an e-PTFE support and a radical scavenger are added. In this study, the chemical durability of the reinforced membrane with ePTFE support and the non-reinforced membrane was compared by Fenton reaction. In the Fenton experiment of the polymer membrane without the addition of a radical scavenger, the absorption rate of hydrogen peroxide solution and iron ions through the cross section of the specimen cut into small pieces was higher in the reinforced membrane, so that the fluorine outflow concentration was higher. According to the type and amount of radical scavenger added, the fluorine outflow concentration of the reinforced membrane has a large difference of more than 3 times, indicating that the effect of the radical scavenger was stronger than that of the support.

Comparisons of Drainage Performance on Coarse Grained Soils with Regard to Horizontal Drainage Type (조립질 지반에서의 수평배수재 종류에 따른 배수성능 비교)

  • Teawan Bang;Wanjei Cho;Seunghwan Seo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.11
    • /
    • pp.25-31
    • /
    • 2023
  • Horizontal drainage, which are representative dewatering method of domestic and foreign slope, are applied to reducing pore water pressure. Accordingly, several previous studies have been conducted, but horizontal drainage are standardized which is an unclean standard for a quantity calculation in filed. Therefore, this study presents field soil and laboratory model box to identify a drainage performance and influencing factors of various horizontal drainage. Furthermore, this study verifies the performance comparison of drainage shape or size according to different particle size distributions. In the outflow results for steady state, the study found that all samples are drained at a constant rate after a minimum of 3 minutes to maximum of 15 minutes. In the case of comparing the outflow per hour (Unit flux) in coarse grained soils, it found that drainage shape and size affect drainage performance. In the result, the future expected to be used basic data that experiment of drainage performance on fine grained soils and determine the quantity.

Total Phosphorus Removal Rate of a Subsurface-Flow Wetland System Constructed on Floodplain During Its Initial Operation Stage (고수부지에 조성한 수질정화 여과습지의 초기운영단계 총인 제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.6
    • /
    • pp.49-55
    • /
    • 2003
  • Total phosphorous removal rate was examined of a subsurface-flow treatment wetland system which was constructed on floodplain in the down reach of the Kwangju Stream in Korea from May to June 2001. Its dimensions were 29 meter in length, 9 meter in width and 0.65 meter in depth. A bottom layer of 45 cm in depth was filled with crushed granite with about 15~30 mm in diameter and a middle layer of 10 cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds(Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju Stream flowed from a submerged dam into it via a pipe by gravity flow and treated effluent was funneled back into the Stream. The number of reed stems increased from 80 stems/$m^2$ in July 2001 to 136 stems/$m^2$ in September 2001. The hight of stems was 44.2 cm in July 2001 and 75.3 cm in September 2001. The establishment of reeds at early operating stage of the system was good. Volume and water quality of inflow and outflow were investigated from July 2001 through December 2001. The average inflow was 40 $m^3$/day and hydraulic detention time was about 1.5 days. The concentration of total phosphorous n influent and effluent was 0.83 and 0.33 mg/L, respectively. The removal rate of total phosphorous averaged about 60%. The removal efficiency was slightly higher, compared with that of subsurface-flow wetlands operating in North America, whose retention rate of total phosphorous was reported to be about 56%. The good abatement rate could be attributed to sedimentation of particle phosphorous in pores of the media and adsorption of phosphorous to the biofilm developed on the surface of them. Increase of standing density of reeds within a few years will develop root zones which may lead to increment in the phosphorous retention rate.

Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area (인공습지에 의한 농촌오수처리에 관한 연구)

  • 윤춘경;권순국;김형중
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF