• Title/Summary/Keyword: Outdoor-Exposure

Search Result 306, Processing Time 0.025 seconds

Vitamin D in athletes: focus on physical performance and musculoskeletal injuries

  • Yoon, Sewoon;Kwon, Ohkyu;Kim, Jooyoung
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.2
    • /
    • pp.20-25
    • /
    • 2021
  • [Purpose] The aim of this review was to discuss the effects of vitamin D on physical performance and musculoskeletal injuries in athletes and provide information on the field applications of vitamin D. [Methods] A systematic review was conducted to identify studies on vitamin D in athletes that assessed serum vitamin D levels, vitamin D and physical performance, vitamin D and musculoskeletal injuries, and practical guidelines for supplementation of vitamin D. [Results] Several studies reported that a high proportion of athletes had vitamin D insufficiency or deficiency. Low serum levels of vitamin D in athletes were more pronounced in winter than in other seasons, and indoor athletes had lower serum vitamin D levels than outdoor athletes. Low vitamin D levels have been demonstrated to have negative effects on muscle strength, power, and endurance; increase stress fractures and other musculoskeletal injuries; and affect acute muscle injuries and inflammation following high-intensity exercises. Therefore, periodic assessment and monitoring of vitamin D levels are necessary in athletes; the recommended serum level of 25(OH)D is > 32 ng/mL and the preferred level is > 40 ng/mL (-1). In those with low levels of vitamin D, exposure to sunlight and an improved diet or supplements may be helpful. Particularly, 2000-6000 IU of supplemental vitamin D3 can be consumed daily. [Conclusion] Vitamin D is a potential nutritional factor that can significantly affect physical performance and musculoskeletal injuries in athletes. The importance and role of vitamin D in athletes should be emphasized, and the current levels of vitamin D should be assessed. Therefore, it is essential to periodically evaluate and monitor serum vitamin D levels in athletes.

Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication (멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1706-1712
    • /
    • 2022
  • Recently, the safety of chemical substances has gained attention due to incidents occurring in petrochemical industrial complexes, such as gas leaks and fires. In particular, industrial complexes in Ulsan and Yeosu (South Korea) are valuable as they significantly contribute to the petrochemical industry, but accidents may occur due to chemical leakage. Therefore, in this study, sensor nodes are configured at an interval of 20 [m] based on outdoor facilities standards to respond to chemical accidents, and exposure consideration of 8 h (TWA) and 15 min (STEL) are proposed in TLVs. The proposed system pre-processes data collected in multi-hop communication at a cycle of 0.6-0.75 [s] using Python and stores it in the MySQL database through SQL and a real-time remote monitoring system that updates the stored data once every 5 s is implemented by linking MySQL and Grafana.

The Impact of Particulate Matter and Public Awareness on the Incidence of Asthma (미세먼지 농도 및 대중의 인식도가 천식질환 발생빈도에 미치는 영향 분석)

  • Ki-Kwang Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.4
    • /
    • pp.32-38
    • /
    • 2023
  • This study investigates the influence of particulate matter concentrations on the incidence of asthma, focusing on the delayed onset of symptoms and subsequent medical consultations. Analysis incorporates a four-day lag from the initiation of fine dust exposure and compares asthma patterns before and after the World Health Organization's (WHO) classification of fine dust as a Group 1 carcinogen in November 2013. Utilizing daily PM10 data and asthma-related medical visit counts in Seoul from 2008 to 2016, the study additionally incorporates Google search frequencies and newspaper article counts on fine dust to assess public awareness. Results reveal a surge in search frequencies and article publications after WHO announcement, indicating heightened public interest. To standardize the long-term asthma occurrence trend, the daily asthma patient numbers are ratio-adjusted based on annual averages. The analysis uncovers an increase in asthma medical visits 2 to 3 days after fine dust events. Additionally, greater public awareness of fine dust hazards correlates with a significant reduction in asthma occurrence after such events, even within 'normal' fine dust concentrations. Notably, behavioral changes, like limiting outdoor activities, contribute to this decrease. This study highlights the importance of analyzing accumulated medical data over an extended period to identify general public behavioral patterns, deviating from conventional survey methods in social sciences. Future research aims to extend data collection beyond 2016, exploring recent trends and considering the potential impact of decreased fine dust awareness amid the COVID-19 pandemic.

Remote work during the COVID-19 pandemic and perception of indoor environment: a focus on acoustic environment (코로나19 팬데믹 기간 재택근무 경험자의 실내환경 인식: 음환경을 중심으로)

  • Sang Hee Park;Hye-kyung Shin;Kyoung-woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.627-636
    • /
    • 2023
  • Due to the COVID-19 pandemic, the global population has experienced drastic changes, one of which is the increase in remote work. Given the ongoing possibility of exposure to infectious diseases and various other circumstances, the expansion of remote work is anticipated. To enhance the efficiency of remote work and address its existing limitations, this study surveyed the perceptions of indoor environments among individuals who worked from home during the COVID-19 pandemic. The study examined how the characteristics of individuals influenced their perceptions of indoor environments. It was found that the number of occupants and rooms, size of the house, and noise sensitivity affected the perceptions of outdoor noise, neighbor noise, and indoor noise caused by cohabitants. The findings can be used as foundational data for designing multipurpose housing that can be utilized not only for residential purposes but also for work and educational settings in the future.

Changes in Air Quality through the Application of Three Types of Green-Wall Model within Classrooms (교사 내 플랜트 모델 유형별 적용에 따른 공기질 변화)

  • Ho-Hyeong Yang;Hyung-Joo Kim;Sung-Won Bang;Heun-Woo Cho;Hyeong-Seok Lee;Seung-Won Han;Kwang-Jin Kim;Ho-Hyun Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.295-304
    • /
    • 2023
  • Background: Adolescents are relatively more sensitive than adults to exposure to indoor pollutants. The indoor air quality in classrooms where students spend time together must therefore be managed at a safe level because it can affect the health of students. Objectives: In this study, three types of green-wall models were applied to classrooms where students spend a long time in a limited space, and the resulting effects on reducing PM were evaluated. Methods: In the middle school classrooms which were selected as the experimental subjects, IoT-based indoor air quality monitoring equipment was installed for real-time monitoring. Three types of plant models (passive, active, and active+light) were installed in each classroom to evaluate the effects on improving indoor air quality. Results: The concentration of PM in the classroom is influenced by outdoor air quality, but repeated increases and decreases in concentration were observed due to the influence of students' activities. There was a PM reduction effect by applying the green-wall model. There was a difference in PM reduction efficiency depending on the type of green-wall model, and the reduction efficiency of the active model was higher than the passive model. Conclusions: The active green-wall model can be used as an efficient method of improving indoor air quality. Additionally, more research is needed to increase the efficiency of improving indoor air quality by setting conditions that can stimulate the growth of each type of plant.

Intensive Culture of the Pacific White Shrimp Litopenaeus vannamei, under Limited Water Exchange - II. Indoor Post-Nursery Culture of Juvenile Shrimp - (사육수 비교환 방식에 의한 흰다리새우의 고밀도 사육 - II. 흰다리새우의 실내 중간양성 -)

  • Jang, In-Kwon;Kim, Jong-Sheek;Seo, Hyung-Chul;Cho, Kook-Jin
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Shrimp farming which is entirely conducted in outdoor ponds in the west coast of Korea has been suffered from mass mortality due to viral epizootics. Intensive indoor shrimp culture under limited water exchange can solve these problems of outdoor ponds including viral transmission from environment, pollution due to discharge of rearing water, low productivity and limited culture period. In this study, juvenile L. vannamei (B.W. 0.08-0.09 g) was stocked with $3,000-5,455/m^3$ in density in four raceway tanks (two $12.9\;m^2$, two $18\;m^2$ tanks) and cultured for 42 days with 2.7-3.4% of daily water exchange. Results from four tanks showed FCR of 0.79-1.29, survival of 38.2-48.0%, and yields of $2.49-4.22\;kg/m^3$ which is consistent with 12-20 and 8-14 times higher than those of commercial shrimp hatchery and outdoor pond in Korea, respectively. Concentrations of total ammonia nitrogen in all four tanks were 1.11-1.42 ppm in mean level and did not exceed 6.0 ppm (0.096 ppm of $NH_3$) which is still acceptable levels for shrimp growth. During the culture trial, concentration of $NO_2$-N rapidly increased from stocking, resulting in mean concentration of 18.45-22.07 ppm. It also exceeded 10 ppm over four weeks and maintained at 35-45 ppm for four days in all tanks, accounting for low survival of shrimp due to long-term exposure to high concentration of $NO_2$-N. Nevertheless, the results with survival rate over 38% from raceways which experienced the extreme $NO_2$-N levels suggests that under "biofloc system" white shrimp can acclimate to high $NO_2$-N concentration to some degree.

Management Strategy of Indoor Hazardous Chemicals (실내.외 통합 모델링 및 인체 위해성 평가를 통한 실내 유해화학물질의 관리 전략)

  • Shin, Yong-Seung;Lim, Hye-Sook
    • Journal of Environmental Policy
    • /
    • v.7 no.2
    • /
    • pp.67-90
    • /
    • 2008
  • The purpose of this study is to develop indoor air quality management strategies regarding indoor air pollutants while considering various factors affecting indoor pollutants concentration. The Integrated Indoor Air Quality model(IIAQ) developed by Seoul National University is used for this study. The IIAQ model is a tool that can provide an integrated view to indoor environmental pollution by simulating suggested scenarios. The results of the modeling are used to assess health risk. The concentrations that are used for the risk characterization are weighted concentrations based on the period of time in each place and existing Indoor Air Quality(IAQ) standards. The estimated concentration of toluene and formaldehyde for 10 years through the IIAQ model was 207.3 $ug/m^3$ and 36.4 $ug/m^3$ in indoors, and 55.9 $ug/m^3$ and 8.62 $ug/m^3$ in outdoors. These concentrations are lower than the existing IAQ standards. The estimated carcinogenic risk of formaldehyde is up to 1.05E-03 for the adult male group and exceeds 1E-06 for all receptor groups. This value means that cancer could affect one person out of 1000. The estimated non-carcinogenic risk of toluene was lower than 1, which means that there was no serious non- carcinogenic risk. The result of modeling shows that using low emitting indoor sources is the most effective strategy for both formaldehyde and toluene. This risk assessment suggests that the total exposure levels of existing IAQ standards may cause serious carcinogenic risk. In order to avoid uncontrolled risk, it is suggested that the current IAQ standards should be adjusted by taking into account the total amount of exposure from all exposure pathways from indoor and outdoor sources.

  • PDF

Sensitivity of Five Clones of Populus alba × P. glandulosa Cuttings to Ozone Exposure in Open-Top Chambers in Relation to Their Growth Rates (Open-Top chamber 내(內)에서 오존에 노출(露出)시킨 현사시 5개(個) 클론의 생장량(生長量)과 오존에 대(對)한 민감성(敏感性)과의 관계(關係))

  • Kim, Tae Kyu;Lee, Kyung Joon;Kim, Goon Bo;Koo, Yong Bon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.1
    • /
    • pp.105-115
    • /
    • 2000
  • This study was conducted to test a hypothesis that sensitivity of trees to ozone exposure was related to their growth rates. Two cultivars of Populus alba ${\times}$ P. glandulosa with different genetic growth potential were used for the comparison. Two clones(72-30, 72-16) of cultivar No. 4 with fast growing potential and three clones(71-28, 72-27, 72-19) of cultivar No. 2 with slow growing potential were propagated in early spring by cutting in $2-{\ell}$ plastic pots. They were grown outdoor for 5 months and exposed in late August for 30 days to 70 and 130ppb ozone in a open-top chambers(2.5m in diameter and 2m in height). Ozone concentration in a control chamber was maintained below 30ppb by filtering with activated charcoal. Each treatment was replicated twenty times. In a control chamber, cultivar No. 4 grew 73%, 64%, and 38% faster than cultivar No. 2 in leaf weight, root weight, and total dry weight, respectively. Visible injury was observed only in cultivar No. 4 in 130ppb treatment. Ozone treatment at both 70 and 130ppb decreased height growth, dry weight of leaf, root, and entire plants in all five clones. Particularly root growth was reduced by 39.7% and 13.8% in cultivar No. 4 and No. 2, respectively, in 70ppb treatment. Consequently, shoot/root ratio of cultivar No.4 was increased by 63.4%, while that of cultivar No.2 was increased by 22.1%. Stomatal conductance decreased more in cultivar No.4 than in cultivar No.2. Net photosynthesis of cultivar No.4 at 130ppb ozone decreased by 69.5%, while that of cultivar No.2 decreased by 31.5%. Above mentioned physiological responses of two cultivars to ozone strongly suggested that fast growing cultivar No.4 was more sensitive to ozone than slow growing cultivar No.2. It was concluded that sensitivity of trees to ozone exposure was closely related to their growth rates.

  • PDF

Effects of Temperature and Light Intensity on the Growth of Red Pepper(Capsicum annuum L.) in Plastic House During Winter. I. Fluctuations of Temperature and Light Environment in the Multilayered Plastic House Grown Red Pepper (동계 Plastic house내 고추(Capsicum annuum L.) 육묘시 온도와 광도가 생장에 미치는 영향 I. 다중피복 고추육묘 시설내의 온도 및 광환경 영향)

  • 정순주;이범선;권용웅
    • Journal of Bio-Environment Control
    • /
    • v.3 no.2
    • /
    • pp.106-118
    • /
    • 1994
  • This study was conducted to analyze the effects of fluctuations in temperature, light intensity and soil temperature on the growth of red pepper seedlings in the nonheated plastic houses with various number of layers and in the open field. Relationship between the optimal environment and the growth of seedlings was discussed, and the maximum and minimum outdoor temperatures in Kwangju area from 1941 to 1985 were analyzed. The results obtained were as follows; 1. The minimum temperature in tunnel with quadruple coverings of P. E. film from December 20 to February 25 was decreased to 5$^{\circ}C$ mostly, where the exposure to chilling temperature could not be avoided during this period. The maximum temperature was increased to 33$^{\circ}C$ mostly and 42$^{\circ}C$ in peak, where some ventilation was needed. 2. The diurnal differences of inside temperature, increasing with number of layers, were 16 to 38$^{\circ}C$, while those of outside temperature were 5 to 1$0^{\circ}C$. 3. The cold injury in the quadruple coverings during winter occurred all the times below 12$^{\circ}C$ and as many as 200 times over 3$0^{\circ}C$, while effectiveness of thermal insulation in the multilayered nonheating plastic houses were clearly proved. 4. The inside light intensity was markedly reduced with the increment of layers and the minimum light intensity fallen down below the light compensation point for the growth of red pepper plants regardless of the number of layers. 5. Until 10 a. m., the temperature in the daytime during December 20 to mid - February showed below 10 to 12$^{\circ}C$ which was the limiting temperature for the growth of red pepper seedlings. After 4 p. m., the light intensity was sharply reduced despite of the air temperature kept over 12$^{\circ}C$. Therefore, limiting factors for the growth of red pepper seedlings were the temperature before 10 a. m. and the light intensity after 4 p. m. 6. The minimum soil temperature in quadruple coverings showed around 1$0^{\circ}C$ where the physiological damage for red pepper seedlings might be occurred. 7. The minimum outdoor temperatures from 1941 to 1985 was -19.4$^{\circ}C$, observed in the 5th January.

  • PDF

Epidemiologic Study of Frostbites and Its Current Managements in Community Hospital (지역 병원에서 동상 환자에 대한 역학에 관한 연구 및 최근 치료)

  • Kim, Dong Chul;Min, Byung Duk;Kim, Ji Hoon;Chung, Chang Eun;Lee, Chong Kun;Yu, Sung Hoon
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.21-29
    • /
    • 2021
  • Purpose: Frostbite is a hazard to people exposed to cold environments. With the progression of modern industrial development and change of leisure behavior encountering cold environments, frequent accidental exposure to frostbite injury during work and human behavior is increasing, and the predisposing factors of frostbite were greatly changed than before. The purpose of this study was to make epidemiological analysis, and to review the treatment outcomes of frostbite. Methods: From March 2010 to February 2021, this study has included 27 patients with second- to third-degree frostbite injuries in Advanced Burn Reconstruction Center, Bundang Jesaeng Hosptial. A retrospective study was made about the distribution of age, gender, predisposing factors, prevalent area, type of managements, and the length of treatment period. Results: In our institution, acute management of frostbite patients has included rewarming, anticoagulation therapy (acetylsalicylic acid), and agents to improve vascular perfusion (lipo-prostaglandin E1 [Eglandin®]). The 25 frostbite patients with second-degree frostbite (92.6%) were successfully managed by the conservative treatment alone with a mean of 20.3 days healing time. Two patients with third-degree frostbite (7.4%) also showed good outcomes after surgical reconstruction with a mean of 59 days healing time. In our clinical experiences of third-degree frostbite, definitive surgical reconstruction should be recommended to wait for more than 4~6 weeks for identification of clear demarcation of necrotic tissue caused by frostbite. In this study, 43 frostbite injuries site in 27 frostbite patients occurred. Among them, 15 patients (55.6%) had multiple-site frostbite injury. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments (40.8%), misapplying ice pack for treatment purposes (7.4%), barefoot walking on the cold ground (3.7%), and loss of consciousness in cold grounds (3.7%). The most prevalent sites of frostbite injuries revealed as the hand (58.1%), followed by the foot (32.6%), face (7.0%), and abdomen (2.3%). And in the winter season from the November to March, the incidence rate of frostbite injuries was high at 74.1%. Conclusion: This study included 27 frostbite patients with 43 frostbite sites since last decade in a single institution at the community hospital. The frostbite patients with second-degree frostbite (92.6%) were successfully healed by the conservative treatment alone with a mean of 20.3 days healing time. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments, etc. The most prevalent site of frostbite injuries was the hand (58.1%). And the most prevalent seasonal incidence of frostbite was from November to March (74.1%).