• 제목/요약/키워드: Outdoor wind effect

검색결과 45건 처리시간 0.023초

생태건축 0번지의 자연에너지 효과에 관한 연구 (A Study on the Natural Energy Effect about the Address No.0 of Eco-friendly Architecture)

  • 이시웅;강병호;임상훈;최승희
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.19-25
    • /
    • 2003
  • The Address No.0 of Eco-friendly Architecture offers unique experience for those who visit the place to envisage the future architecture where nature, human and building exist in harmony. It is open to the general public including the students of elementary and secondary schools. This house has been built to provide opportunities for the general public to experience eco-friendly architecture. It's floor area is 42 pyung($140m^2$) and the overall site has the area of 180 pyung($600m^2$). The following illustrates some of its prominent features : ${\bullet}$ Remodeling of a traditional Korean residence ${\bullet}$ Application of passive solar systems ${\bullet}$ Use of clerestory windows and daylighting systems(washroom and machine room) ${\bullet}$ Operation of solar water heaters with flat plate collectors ${\bullet}$ Construction of Biotop(small ecological world) ${\bullet}$ Water circulation for Biotop by photovoltaic(150W) and wind power(400W) generation ${\bullet}$ Outdoor hot water supplied by all-glass evacuated solar tubes. Through this Address No.0 of Eco-friendly Architeture conclusions are as followings. 1. The array of tubes in collector has the best nice in that the number of tube is nine and the tilt angle is the latitude $+20^{\circ}$. 2. The thermal performance of the all-glass solar vacuum collector was excellent than of the flate-plate solar collector. 3. The adaption of new small wind power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building hight.

Evaluation of the Wet Bulb Globe Temperature (WBGT) Index for Digital Fashion Application in Outdoor Environments

  • Kwon, JuYoun;Parsons, Ken
    • 대한인간공학회지
    • /
    • 제36권1호
    • /
    • pp.23-36
    • /
    • 2017
  • Objective: This paper presents a study to evaluate the WBGT index for assessing the effects of a wide range of outdoor weather conditions on human responses. Background: The Wet Bulb Globe Temperature (WBGT) index was firstly developed for the assessment of hot outdoor conditions. It is a recognised index that is used world-wide. It may be useful over a range of outdoor conditions and not just for hot climates. Method: Four group experiments, involving people performing a light stepping activity, were conducted to determine human responses to outside conditions in the U.K. They were conducted in September 2007 (autumn), December 2007 (winter), March 2008 (spring) and June 2008 (summer). Environmental measurements included WBGT, air temperature, radiant temperature (including solar load), humidity and wind speed all measured at 1.2m above the ground, as well as weather data measured by a standard weather station at 3m to 4m above the ground. Participants' physiological and subjective responses were measured. When the overall results of the four seasons are considered, WBGT provided a strong prediction of physiological responses as well as subjective responses if aural temperature, heart rate and sweat production were measured. Results: WBGT is appropriate to predict thermal strain on a large group of ordinary people in moderate conditions. Consideration should be given to include the WBGT index in warning systems for a wide range of weather conditions. However, the WBGT overestimated physiological responses of subjects. In addition, tenfold Borg's RPE was significantly different with heart rate measured for the four conditions except autumn (p<0.05). Physiological and subjective responses over 60 minutes consistently showed a similar tendency in the relationships with the $WBGT_{head}$ and $WBGT_{abdomen}$. Conclusion: It was found that either $WBGT_{head}$ or $WBGT_{abdomen}$ could be measured if a measurement should be conducted at only one height. The relationship between the WBGT values and weather station data was also investigated. There was a significant relationship between WBGT values at the position of a person and weather station data. For UK daytime weather conditions ranging from an average air temperature of $6^{\circ}C$ to $21^{\circ}C$ with mean radiant temperatures of up to $57^{\circ}C$, the WBGT index could be used as a simple thermal index to indicate the effects of weather on people. Application: The result of evaluation of WBGT might help to develop the smart clothing for workers in industrial sites and improve the work environment in terms of considering workers' wellness.

Correlation Between the “seeing FWHM” of Satellite Optical Observations and Meteorological Data at the OWL-Net Station, Mongolia

  • Bae, Young-Ho;Jo, Jung Hyun;Yim, Hong-Suh;Park, Young-Sik;Park, Sun-Youp;Moon, Hong Kyu;Choi, Young-Jun;Jang, Hyun-Jung;Roh, Dong-Goo;Choi, Jin;Park, Maru;Cho, Sungki;Kim, Myung-Jin;Choi, Eun-Jung;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권2호
    • /
    • pp.137-146
    • /
    • 2016
  • The correlation between meteorological data collected at the optical wide-field patrol network (OWL-Net) Station No. 1 and the seeing of satellite optical observation data was analyzed. Meteorological data and satellite optical observation data from June 2014 to November 2015 were analyzed. The analyzed meteorological data were the outdoor air temperature, relative humidity, wind speed, and cloud index data, and the analyzed satellite optical observation data were the seeing full-width at half-maximum (FWHM) data. The annual meteorological pattern for Mongolia was analyzed by collecting meteorological data over four seasons, with data collection beginning after the installation and initial set-up of the OWL-Net Station No. 1 in Mongolia. A comparison of the meteorological data and the seeing of the satellite optical observation data showed that the seeing degrades as the wind strength increases and as the cloud cover decreases. This finding is explained by the bias effect, which is caused by the fact that the number of images taken on the less cloudy days was relatively small. The seeing FWHM showed no clear correlation with either temperature or relative humidity.

음선 추적을 이용한 폭발음 위치추정 오차 보정에 대한 연구 (Study on Error Correction of Impact Sound Position Estimation Using Ray Tracing)

  • 최동훈;고영주;이재형;나태흠;최종수
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.89-96
    • /
    • 2016
  • TDOA(time delay of arrival) position estimate from acoustic measurement of artillery shell impact is studied in order to develop a targeting evaluation system. Impact position is calculated from the intersections of hyperbolic estimates based on the least square Taylor series method. The mathematical process of Taylor series estimation is known to be robust. However, the concern lays with the accuracy because it is sensitive to the bias caused by the randomness of measurement situation. The measurement error typically occurs from the distortion of waveform, change of travelling path, and sensor position error. For outdoor measurement, a consideration should be made on the atmospheric condition such as temperature and wind which can possibly change the trajectories of rays of sound. It produces wrong propagation time events accordingly. Ray tracing and optimization techniques are introduced in this study to minimize the bias induced by the ray of sound. The numerical simulation shows that the atmospheric correction improves the estimation accuracy.

현시(顯示)적 조경작품의 특성 연구 (A Study on the Characteristics of Revelatory Landscape Projects)

  • 김정호
    • 한국조경학회지
    • /
    • 제35권2호통권121호
    • /
    • pp.37-48
    • /
    • 2007
  • An exhibit entitled 'Revelatory Landscapes' was held at the San Francisco Museum of Modem Art from May 5 to October 14, 2001. For this Museum's rot off-site outdoor exhibition, five outstanding design teams-Kathryn Gustafson, Hargreaves Associates, Hood Design, Tom Leader Studio, and ADOBE LA-created site-specific installations in Berkeley, Oakland, San Jose, and the San Francisco Bay Area. Each project showcased a hybridization of environmental art and landscape design. The main content revealed through revelatory landscapes were the natural, cultural, and historical palimpsest of the sites-particularly as related to the history of minorities such as Native American, African Americans and Latin Americans-as well as the every day life of ordinary people. To represent these ideas, a juxtaposition of the past and the present was broadly applied. Furthermore, the use of dramatic colors, textures, and forms in consideration of materials coupled with the revelation of natural elements such as wind and sunlight accelerated the effect of this juxtaposition. Every project of the Revelatory Landscapes exhibit requires a phenomenological experience to be appreciated. Via the five senses, these experiences cause a synesthetic experience beyond solely the visual. By examining the projects of 'Revelatory landscapes', the threshold for a new blending between environmental art and landscape design as well as new landscape design strategies that overcome the dichotomy between nature and culture will change and evolve.

전력용 변압기 외함 소음저감에 관한 연구 (A Study on the Tank Noise Reduction Techniques of Power Transformers)

  • 권동진;구교선;김정찬;김유현
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1759-1766
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.

수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

자연 환기식 온실의 모델 기반 환기 제어를 위한 미기상 환경 예측 모형 (Predictive Model of Micro-Environment in a Naturally Ventilated Greenhouse for a Model-Based Control Approach)

  • 홍세운;이인복
    • 생물환경조절학회지
    • /
    • 제23권3호
    • /
    • pp.181-191
    • /
    • 2014
  • Modern commercial greenhouse requires the use of advanced climate control system to improve crop production and to reduce energy consumption. As an alternative to classical sensor-based control method, this paper introduces a model-based control method that consists of two models: the predictive model and the evaluation model. As a first step, this paper presents straightforward models to predict the effect of natural ventilation in a greenhouse according to meteorological factors, such as outdoor air temperature, soil temperature, solar radiation and mean wind speed, and structural factor, opening rate of roof ventilators. A multiple regression analysis was conducted to develop the predictive models on the basis of data obtained by computational fluid dynamics (CFD) simulations. The output of the models are air temperature drops due to ventilation at 9 sub-volumes in the greenhouse and individual volumetric ventilation rate through 6 roof ventilators, and showed a good agreement with the CFD-computed results. The resulting predictive models have an advantage of ensuring quick and reasonable predictions and thereby can be used as a part of a real-time model-based control system for a naturally ventilated greenhouse to predict the implications of alternative control operation.

소나무 성 결정 요인의 특성을 고려한 조경공간 식재계획 (A Study on the Plant Planning in Landscape Space Considering the Characteristics of the Gender Determination of Pine Tree)

  • 이창훈
    • 한국전통조경학회지
    • /
    • 제38권1호
    • /
    • pp.45-52
    • /
    • 2020
  • 본 연구는 무기원소의 체내 함량이 소나무의 성 결정에 미치는 요인을 분석하기 위해 1, 2년생 솔잎에 포함된 성분을 분석하였으며, 이에 생육환경과 생리적 특성 고려한 소나무 식재계획 및 유지관리 방안을 제시하고자 하였다. 그 결과는 다음과 같다. 첫째, 구과가 많이 맺힌 작년가지의 잎에서 분석된 N(%)함량이 높은 것으로 나타났으며, 작년토양의 질소성분은 다음 연도 구과의 생성에 영향을 주는 것으로 파악되었다. 이는 전년도 봄에 질소비료를 이용한 시비작업을 통해 다음해 신초에서 생성되는 송화비율의 저감이 가능할 것으로 판단된다. 둘째, 1년생 가지의 구과 및 송화가 열리는데 관계하는 성분은 인산(P), 칼륨(K), 칼슘(Ca), 철(Fe)이 유의미한 것으로 파악되었으며, 전년도에 생성된 Ca과 Fe는 신초의 성 결정에 낮은 영향력을 보이는 것으로 나타났다. Ca과 Fe는 노화된 기관에 축적된 영양소의 이동이 어려운 특성을 지니므로 이듬해 봄철 구과생성에 영향을 미칠 수 있도록 전년도 가을에 양분을 공급을 주어야 할 것으로 생각된다. 셋째, 소나무의 송화가루는 봄철 북동풍이 부는 시기와 관련 있고 극양수의 속성을 지니므로 옥외공간에 식재할 때 볕이 잘 드는 북향이 적합한 것으로 판단된다. 또한 조경공간에 식재된 송화가루의 저감효과를 위해 봄철에 질소비료로 양분을 비축하고, 가을철에 Mg, Fe성분이 포함된 시비작업을 실시하는 것은 소나무의 성 결정 뿐만 아니라 소나무의 유지하고 관리계획에 고려되어야 할 사안으로 보인다. 본 연구는 소나무 무기원소 함량이 성 결정에 미치는 상관관계를 도출하고 소나무의 생리적 특성을 고려한 식재계획은 옥외공간 조성에 있어 중요한 사안임을 밝혔으며, 기타 소나무 성 결정에 영향을 주는 요인을 주제로 한 후속연구가 기대되는 바이다.

운동장 포장재료가 인간 열환경에 미치는 영향 (Influence of Playground Land Covers on the Human Thermal Sensation)

  • 현철지;조상만;박수국
    • 한국조경학회지
    • /
    • 제47권3호
    • /
    • pp.12-21
    • /
    • 2019
  • 다양한 운동장 포장재료(인조잔디, 천연잔디, 마사토)가 인간 열 환경에 미치는 영향을 알아보기 위해 초 가을철 미기후자료(기온, 습도, 풍속, 태양 및 지구복사에너지)를 측정하여 비교분석하여 보았다. 그 결과, 포장재료에 따른 기온, 습도, 풍속은 평균적으로 차이가 크지 않았으며, 평균복사온도에서 가장 큰 차이를 보여주었다. 태양복사에너지에서는 태양복사에너지 반사율(알베도)이 가장 높았던 천연잔디에서, 지구복사에너지에서는 지표면 온도가 가장 높았던 인조잔디에서 가장 높은 복사에너지를 인체에 보내는 것으로 나타났다. 인간 열환경지수 PET에서는 인조잔디>마사토>천연잔디 순으로 나타났으며, 천연잔디포장이 인조잔디포장보다 최대 2/3 단계 평균적으로 1/2 단계 낮은 열환경을, 마사토 포장은 인조잔디포장보다 최대 2/3 단계 평균적으로 1/3 단계 낮은 열환경을 조성할 수 있는 것으로 나타났다. 천연잔디포장은 마사토 포장에 비해 최대 1/3 단계 낮은 열환경을 조성할 수 있는 것으로 나타났다. UTCI에서는 PET보다 더 작은 차이를 보이는 것으로 나타났다. 그러므로, 운동장을 포함한 옥외공간 설계 시 계획단계에서부터 재료 선정에 신중을 기하여야 할 것이다.