• Title/Summary/Keyword: Outdoor air

검색결과 974건 처리시간 0.033초

공기중 염화비닐단량체 포집시 온도가 파과현상에 미치는 영향 (The Effect of Temperature on the Breakthrough of Charcoal Tube During Vinyl Chloride Monomer Sampling)

  • 박윤정;이상회;김치년;원종욱;노재훈
    • 한국산업보건학회지
    • /
    • 제8권1호
    • /
    • pp.115-123
    • /
    • 1998
  • Vinyl chloride monomer exists as gas phase at normal temperature and reacts with oxygen and strong oxidant in the air to form oxidized materials. Because of being easily synthesized, it is used as a main source at the synthetic reaction process of PVC synthesis factories. Ministry of Labor regulates its usage as a carcinogen and its exposure level as 1 ppm. But the amount of VCM production in PVC and VCM production process hasn't been exactly estimated. In addition, facilities of this factory are located in outdoor. Therefore, this study was designed to investigate effects of temperature on breakthrough of charcoal tube at a fixed concentration and temperature during VCM sampling based on NIOSH and OSHA methods which were used as methods of occupational environment measuring and analysis. During the sampling of VCM, methods of OSHA and NIOSH require flow rate of 0.05 lpm and sampling volume of $3{\ell}$, $5{\ell}$ respectively, at this time carbon molecular sieve tube and coconut shell charcoal tube are used to observe the breakthrough along with concentration and temperature. As a result, significant difference between average adsorbed amounts of OSHA methods but that of NIOSH methods cannot be found. NIOSH method is likely to be effected by high temperature and normal temperature in high concentration. Breakthrough is not found in the method of OSHA at different conditions of temperature and concentration. As the result of this study we could verify that breakthrough occurred in the process of sampling VCM with NIOSH methods. Therefor in summer time, breakthrough should be considered and research on the breakthrough volume should be done. It is considered the research about the specificity of the coconut shell charcoal and carbon molecular sieve sorbent should be done when sampling VCM in comming days.

  • PDF

목탄을 이용한 친환경 건축자재 이용기술(II) - 목탄 함유 건축자재의 에너지 절감 및 차음 특성에 관한 연구 (Utilization of Charcoal as an Environmentally Friendly Building Materials (II) - A Study on the Energy Saving and Sound Insulation Characteristics of Building Materials Prepared with Charcoal -)

  • 안병준;백기현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.41-52
    • /
    • 2011
  • 본 연구는 목탄을 첨가한 건축자재의 에너지 절감 및 차음특성을 조사하기 위하여 수행되었다. 건축자재 형태에 따른 특성을 조사하기 위하여 3동의 실험 건물을 신축하였다. 이들 실험 건물은 각각 일반건축자재(A), 목탄건축자재(B) 및 목탄 sericite 건축자재(C)를 사용하여 신축하였다. 건축자재 형태별 동절기의 보일러 난방 기름소모량을 조사한 결과, B를 사용할 경우 A를 사용한 건물과 비교하여 평균 9.5%, C를 사용할 경우에는 평균 14.9%의 기름절감 효과를 나타냈다. 특히 기름 절감효과는 외부기온이 낮을수록 큰 것으로 조사되었다. 또한 B를 적용한 건물은 A나 C를 사용한 건물과 비교하여, 난방온도가 상당히 완만하게 낮아졌으며, 보일러 가동 중단 12시간 경과 후 지상 1미터 공기부에서 $3.5{\sim}4.2^{\circ}C$, 바닥표면에서는 $4.4{\sim}5.4^{\circ}C$ 높게 나타났다. 건물 소음시험에 있어서는, 목탄을 포함하는 시험체는 다층건물의 층간소음 기준으로 대표되는 중량충격음과 경량충격음 모두에서 저감효과를 나타냈다.

개방에 따른 실내 온습도 변화가 목조문화재 보존환경에 미치는 영향 예측 (Predicting Influence of Changes in Indoor Air Temperature and Humidity of Wooden Cultural Heritages by Door Opening on Their Conservation Environment)

  • 김민지;신현경;최용석;김광철;김규혁
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.798-803
    • /
    • 2015
  • 1년간 측정된 개방 및 인접 비개방 전각의 실내 온습도 및 목재 기둥 내측의 표면함수율을 문헌조사를 통해 확인된 목재 가해균류 포자 발아와 생육이 가능한 최소 온습도(최소 습도의 지속기간 포함)와 목재 함수율과 비교하는 간접적인 방법으로 전각 개방이 전각 내부 보존환경에 미치는 영향을 예측하였다. 개방 여부에 관계없이 연중 전각 내부의 온습도 및 목재 함수율 조건은 부후균과 변재변색균의 생육에는 부적절하였으나 장마철이 포함된 여름철 전각 내부의 온습도 및 목재 함수율 조건은 표면오염균의 생육에 적절하였다. 표면오염균 생육을 위한 상대습도 및 목재 함수율 조건, 즉 실내 상대습도가 75% 이상으로 상승한 후 지속되는 기간과 목재 기둥 내측의 표면함수율이 15% 이상으로 상승되는 총 일수를 비교할 때, 전각 내부의 표면오염균 관련 보존환경은 개방 전각이 비개방 전각에 비해 다소 우수하다고 할 수 있다. 오히려 비개방 전각의 경우, 외기 상대습도가 높아지는 여름철에는 전각 내부의 상대습도를 낮추기 위해 문을 개방할 필요가 있다고 사료된다.

사중극자 보정 Ffowcs Williams and Hawkings 방정식을 이용한 수중 익형 공동 유동소음에 대한 수치적 고찰 (Numerical investigation into cavitation flow noise of hydrofoil using quadrupole-corrected Ffowcs Williams and Hawkings equation)

  • 구가람;유서윤;정철웅
    • 한국음향학회지
    • /
    • 제37권5호
    • /
    • pp.263-270
    • /
    • 2018
  • 외부 유동소음 문제를 다루는 대부분의 산업현장에서 FW-H(Ffowcs Williams and Hawkings) 방정식을 이용한 복합전산공력음향 기법이 수치적인 효율성으로 인하여 널리 사용되고 있다. 그러나 사중극자항을 무시한 면적분 형태의 FW-H 방정식을 사용할 때 경우에 따라 무시할 수 없는 비물리적인 소음이 발생한다고 알려져 있다. 특히, 수중 프로펠러와 같이 날개 끝 와류 공동(tip vortex cavitation)이 하류방향으로 길게 형성되는 유동에 대해서는 적절하게 모델링하지 않으면 소음 예측의 정확도가 떨어지게 된다. 따라서 본 연구에서는 사중극자 보정항을 추가하여 적분면에서 FW-H 방정식으로부터 발생하는 비물리적인 음향을 저감시키고자 하였다. 먼저 FW-H 방정식에 기초하여 개발한 내부 예측코드의 정확성을 확인하기 위하여 에어컨 실외기에 사용되는 축류팬을 대상으로 검증을 수행하였으며, ANSYS Fluent의 결과와 비교하여 잘 일치하는 것을 확인하였다. 사중극자 보정항의 효과를 확인하기 위하여 등엔트로피 와류 전파에 대한 소음 해석을 수행하였으며, 사중극자 보정항에 의한 오차의 저감 효과가 발생하는 것을 확인하였다. 마지막으로 Clark-Y 수중익형에서 발생하는 공동 유동장을 대상으로 소음 해석을 수행하였으며, 공동이적분면을 통과할 때 발생하는 오차를 사중극자 보정항을 이용하여 저감할 수 있다는 것을 확인하였다.

자연 및 인위적 처리방법 변화에 따른 순환잔골재의 pH저감 (Reduction of pH of Recycled Fine Aggregate due to Natural and Artificial Treatment Method)

  • 한천구;한민철;한상윤
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.103-110
    • /
    • 2011
  • 본 연구는 폐콘크리트로부터 발생한 성토 복토용 순환잔골재의 pH 저감을 목적으로 자연적 처리 방법 및 인위적 처리 방법을 이용하여 순환잔골재의 pH 저감특성을 비교 분석 하고자 하였는데, 그 결과를 요약하면 다음과 같다. 실내방치된 순환잔골재의 경우는 사람의 호흡 등 대기중 높은 $CO_2$농도로 인해 실외방치된 순환잔골재보다, 또한 쌓기 두께가 얇을수록 pH를 저감시킨 것으로 분석된다. 공기투과의 경우 비교적 순환잔골재의 pH저감이 효과적이었는데 이는 고압의 환풍기로 인해 순환잔골재에 원활한 $CO_2$ 공급으로 pH를 저감시킨 것으로 판단된다. 살수처리의 경우 미수화 시멘트의 수화반응을 촉진시켜 수산화칼슘을 용해시키고, 건조과정중 대기중 $CO_2$에 의한 중성화로 pH를 크게 저감시키는 것으로 나타났으며 침수처리에서는 pH 저감 효과가 미흡하였다. $CO_2$촉진의 경우 순환잔골재의 pH저감 효과가 가장 우수한 것으로 나타났는데, 이는 원활한 $CO_2$공급이 가능하기 때문인 것으로 분석된다. 이상의 실험 결과를 종합하면, pH 저감성능, 경제성 및 작업성 측면을 고려할 경우 순환잔골재 질량비 1: 0.5 비율로 살수한 다음, 강제적인 $CO_2$가스의 처리로 건습을 반복한다면 순환잔골재의 pH저감에 가장 효과적인 방법이 될 것으로 분석된다.

  • PDF

온돌 수면환경이 인체의 온열생리반응에 미치는 영향 (Effects of Ondol Sleep Environment on the Thermo-physiological Response of the Human Body)

  • 김정숙;성수광
    • 한국의류산업학회지
    • /
    • 제1권2호
    • /
    • pp.173-181
    • /
    • 1999
  • 한국의 청실양식은 84.9%가 요와 이불을 사용하여 온돌의 방바닥에 누워 자는 형식이다. 이에 본 연구는 온돌 난방 주택에서의 수연환경의 실태를 파악하기 위하여 온돌침실의 온열환경, 침상기후, 수면시 생리반응을 각 가정의 일상생활 중에서 직접 측정하여 계절별, 주택형태별에 따른 수면환경의 차이를 분석하였다. 그 결과, 계절 및 주택형태별에 따른 수면환경의 큰 온도차이에도 불구하고 수면 중 인체와 접촉하는 이불 밑과 요 시트의 침상온도는 계절과 주택형태에 관계없이 연평균 $30.5{\sim}34.1^{\circ}C$로 쾌적한 침상 내 온도를 나타내었을 뿐만 아니라 수면 중 직장온도도 연평균 $36.8^{\circ}C$로 계절 및 주택형태에 따른 유의한 차이는 인정되지 않았다. 그러나 침실환경에 대한 주관적 온열감각은 주택형태에 따라 유의한 차이를 나타내어 침실의 온열 중성점이 아파트 $25.9^{\circ}C$, 단독주택 $20.3^{\circ}C$로 아파트가 단독주택보다 $5.6^{\circ}C$ 높게 나타났다. 이는 건물의 구조가 주택은 조적조의 구조인 반면 아파트는 철근콘크리트의 구조로 우수한 단열력을 가지므로 외기온의 영향을 받기 어려워 높은 실내온도를 유지하였기 때문이다. 뿐만 아니라 거주자들이 주택 내 환경에 적응되어진 결과라고도 할 수 있겠으나 아파트 거주자의 측면에서는 온열환경에 대한 에너지 절약, 건강 유지 등의 관점에서 보다 효율적인 난방을 위한 쾌적한 생활온도 설정을 재고할 필요가 있다고 하겠다.

  • PDF

군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향 (The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress)

  • 한상환;조수헌;고경심;권호장;하미나;주영수;신명희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권2호
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

성덕대왕신종(聖德大王神鍾) 당목(撞木)의 수종(樹種)과 열화(劣化) (Species Identification and Weathering of Wooden Striker on the Divine Bell of King Songdok)

  • 강애경
    • 박물관보존과학
    • /
    • 제4권
    • /
    • pp.71-78
    • /
    • 2003
  • 성덕대왕신종 당목의 수종과 오랜 세월동안 외부적인 요인(태양빛, 수분, 온도, 공기)에 의한 열화를 조사하였다. 당목의 수종은 느티나무(느릅나무과, Zelkova serrata)로 밝혀졌다. 열화로 인한 변화를 육안으로 관찰하였을 때 표면변색, 할렬, 목재면의 거칠어짐이 나타났다. 미세형태학적인 변화는 열화형태에 따라 세 부분(I, II, III-spot)으로 나누어 관찰하였다. I-spot에는 재색으로 변색됨과 동시에 조직의 관찰이 불가능할 정도로 먼지층이 완전히 조직을 뒤덮고 있었다. 그와 달리 변색이 되었지만 조직의 관찰이 가능한 II-spot는 무수한 균사와 세포내강에 유입된 먼지 등의 오염물이 관찰되었다. 세포벽은 열화로 인해 물리적인 강도를 소실하여 약화되어 있으며 그로 인해 세포벽의 미세한 할렬과 찢김 등을 관찰할 수 있었다. 균사가 세포를 뒤덮고 있지만 그로 인한 목재 부후는 관찰되지 않았다. 표면에서 불과 0.5 mm 아래의 III-spot는 목재의 고유한 적갈색을 유지하고 있으며 세포벽은 건전재와 유사하였다. 이상의 변화들은 목재부후와는 구별되었으며 표면에서 불과 0.5 mm 이하의 지극히 표면적인 현상이라고 할 수 있다.

외기의 풍속 및 풍향에 따른 옥내저탄장 내부 유동 해석 (Flow Analysis indoor Coal Storage Shed due to Wind Velocity and Wind Direction of Ambient Air)

  • 김태권;조목량;배영완;김지원
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.538-545
    • /
    • 2020
  • 화력발전소의 옥외 저탄장은 주변 지역의 환경오염 문제로 인하여 국내외적으로 옥내 저탄장으로 전환되고 있는 추세이다. 하지만 옥내 저탄장의 경우 실내의 석탄 비산과 유해가스의 발생이 문제가 되고 있다. 본 연구는 옥내 저탄장 내부를 외기의 풍속 및 풍향에 따른 내부 유동장 특성과 환기량을 분석하여 환기 방안을 제시하고자 한다. 옥내 저탄장 내부에서의 실제 유동 측정 정보를 기반으로 하여 CFD 해석을 수행하였다. 외기 풍향이 동풍일 때 풍속이 6 m/s인 경우와 2 m/s인 경우를 비교해본 결과는 6 m/s일 때 Monitor louver로 배출되는 유속이 2 m/s일 때보다 빠르며 재순환 영역이 뚜렷하게 나타났다. 또한 외기 풍향이 서풍일 경우에도 동풍과 경향이 비슷함을 확인하였다. 풍속에 따른 환기량을 확인한 결과는 풍속이 6 m/s인 경우에는 환기 횟수는 13.1회, 2 m/s인 경우에는 4.4회의 환기가 가능하다. 풍속이 2 m/s인 경우에 일반 공장의 시간당 필요 환기 횟수에 미치지 못하여 다소 개선이 필요한 실정이다.

적산온도에 의한 FRC 기층의 강도발현 성능 분석 (Performance Analysis of Strength Development of FRC Base Depending on Maturity)

  • 최성용;박영환;정우태
    • 한국도로학회논문집
    • /
    • 제18권1호
    • /
    • pp.13-21
    • /
    • 2016
  • PURPOSES : In this study, we analyzed the compressive strength characteristics of lean base concrete in relation to changes in the outdoor temperature after analyzing the cold and hot weather temperature standards and calculated the minimum and maximum temperatures when pouring concrete. We examined the rate of strength development of lean base concrete in relation to the temperature change and derived an appropriate analysis formula for FRC base structures by assigning the accumulated strength data and existing maturity formula. METHODS : We measured the strength changes at three curing temperatures (5, 20, and $35^{\circ}C$) by curing the concrete in a temperature range that covered the lowest temperature of the cold period, $5^{\circ}C$, to the highest temperature of the hot period, $35^{\circ}C$. We assigned the general lean concrete and FRC as test variables. A strength test was planned to measure the strength after 3, 5, 7, 14, and 28 days. RESULTS : According to the results of compressive strength tests of plain concrete and FRC in relation to curing temperature, the plain concrete had a compressive strength greater than 5 MPa at all curing temperatures on day 5 and satisfied the lean concrete standard. In the case of FRC, because the initial strength was substantially reduced as a result of a 30% substitution of fly ash, it did not satisfy the strength standard of 5 MPa when it was cured at $5^{\circ}C$ on day 7. In addition, because the fly ash in the FRC caused a Pozzolanic reaction with the progress into late age, the amount of strength development increased. In the case of a curing temperature of $20^{\circ}C$, the FRC strength was about 66% on day 3 compared with the plain concrete, but it is increased to about 77% on day 28. In the case of a curing temperature of $35^{\circ}C$, the FRC strength development rate was about 63% on day 3 compared with the plain concrete, but it increased to about 88% on day 28. CONCLUSIONS : We derived a strength analysis formula using the maturity temperatures with all the strength data and presented the point in time when it reached the base concrete standard, which was 5 MPa for each air temperature. We believe that our findings could be utilized as a reference in the construction of base concrete for a site during a cold or hot weather period.