• Title/Summary/Keyword: Outdoor PM10

Search Result 197, Processing Time 0.028 seconds

User Benefit Characteristics of Customized Housing Design Guideline for Childcare Families (사용자혜택 이론에 따른 신혼·육아가구 맞춤형 주택계획가이드 라인의 특성 연구)

  • Lee, Yeunsook;Ahn, Somi;Park, Jaehyun
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.63-70
    • /
    • 2016
  • Modern society is suffering from the phenomena of low-fertile, ultra-aging, and low-growth. On this social flow, most social classes undergo vulnerable situation and their overall housing and living condition have difficulties. So far many housing guidelines for diverse population were developed, recently, inclusive 'Customized Housing Design Guideline for Childcare Families' in terms of maintaining family and society has been completed. The purpose of this study is to analyze User Benefit Characteristics of 'Customized Housing Design Guideline for Childcare Families'. The research subjects are essential 140 guidelines appropriate to children's development and parents' care. The research method is contents analysis and the analysis criterion are 4 concepts of the User Benefit Criteria- 'Behavioral Facilitation (BF)', 'Physiological Maintenance (PhM)', 'Perceptual Maintenance (PM)', 'Social Facilitation (SF)'. 3 people inter-raters reliability was established. Altogether, the guidelines were rated in the order of PhM>PM>BF>SF, and these characteristics are similar as common universal design guidelines. This showed the supportability of spatial characteristics in the guidelines related to user's special behaviors. Also, the results show the importance of outdoor space planning for safe social interactions. The supportable characteristics of 'Customized Housing Design Guideline for Childcare Families' could be expected to efficiently apply for new housing development in the future.

A field survey on the standard establishment of wearing under environmental thermal conditions II - With emphasis on yearly change of wearing and clothing weight - (환경온도조건하의 착의표준설정에 관한 조사연구(ll))

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.23 no.4
    • /
    • pp.33-54
    • /
    • 1985
  • The purpose of this study is to establish the suitable wearing standard under environmental thermal conditions in Pusan. The data is obtained from 50 girl students from April, 1984 to March, 1985. Items of the research are as follows : Environmental conditioni, clothing weight, contents of wearing, clothing climate, wearing order etc. RESULTS : 1. The upper clothing wights are varied considerably with temperature, while the lower are not. 2. The outdoor temperature and the total clothing weights show the high negative correlation of r=-.97 wth regression equation of Y=-37.64X+1692.66. 3. The clothing weight per clo is 390g/$m^2$. 4. Mostly, subjects were 2~7kinds of the upper and 3~5kinds of the lower clothing. 5. The clothing weights on the upper part of the body are heavier than those on the lower part of it. 6. The standard deviation of the obver clothing is larger than that of the under clothing. 7. The clothing shape of comfort-sensation reporter changes with variation of temperature. 8. The clothing climate of the inner layer is 32.26$\pm$$0.5^{\circ}C$ in temperature, 43.6$\pm$7% in humidity at four seasons. 9. It is represented that total subjects and comfort-sensation reporter control the wearing contents suitably for temperature. 10. The standard of wearing in Pusan is established as Fig. 6.

  • PDF

A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season (겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구)

  • Chang, Hyun-Jae;Cho, Keun-Je
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

Effects of Indoor Greening Method on Temperature, Relative Humidity and Particulate Matter Concentration (실내녹화 방법이 온·습도 및 미세먼지 농도에 미치는 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.1-10
    • /
    • 2017
  • This study investigated indoor temperature and humidity control and PM1 and PM10 mitigation effects of a single green wall (Case 1), two green walls (Case 2), and two green walls plus a waterfall (Case 3) in comparison with a control without either a green wall or waterfall. Experiments were conducted in the office of Chungbuk National University from August to September, 2015. Experiments were carried out sequentially in the order of control, Case 1, Case 2, and Case 3. Data collected from August 17 to August 20, 2015 (Experiment 1), and from August 31 to September 3, 2015 (Experiment 2), when outdoor temperature was relatively constant, were analyzed. Plant volume ratios by indoor landscaping of the control, Case 1, Case 2 and Case 3 were 0.0, 0.6, 1.2, and 1.4%, respectively. Compared to the control, average temperatures of Case 1, Case 2 and Case 3 were decreased by 0.3~0.7, 0.7~0.9 and $1.0^{\circ}C$, respectively, and relative humidity was increased by 1.8~8.7, 9.2~14.6 and 14.8~21.9%, respectively. Three hundred minutes after exposure to mosquito repellent incense particles, the ratio of the remaining PM1 of the control, Case 1, Case 2 and Case 3 were 25.0, 22.0%, 21.2%, 17.3%, respectively, in Experiment 1 and 42.3, 28.9, 23.1, and 30.9%, respectively, in Experiment 2. As indoor greening increased the effect of indoor temperature, PM1 and PM10 mitigation were greater, and temperature and humidity were lower. The greater the relative humidity was, the faster PM1 and PM10 mitigation tended to be.

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

Prevalence of Children's Allergic Diseases in Ulsan: Local Differences and Environmental Risk Factors (울산지역 초등학생 알레르기 질환 유병률: 지역적 차이와 환경위험인자)

  • Oh, In-Bo;Kim, Yangho;Sim, Chang Sun;Lee, Ji Ho
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.472-481
    • /
    • 2012
  • Objectives: This study aims to investigate the AD (allergic diseases: asthma, allergic rhinitis and atopic dermatitis) prevalence among elementary schoolchildren in an industrial city, Ulsan, and identify major environmental risk factors associated with AD prevalence. Methods: Data on the physician-diagnosed prevalence over the past 12 months and potential risk factors of AD were collected through a questionnaire from a 2009-2010 survey of 4,067 schoolchildren living in different urban environments. The logistic regression analysis was performed to assess differences in AD prevalence among the areas and to determine which environmental factors impacted AD. Results: Our survey results showed that the AD prevalence rate ranged between 26.2% and 35.9%. Children living in polluted areas (near industrial and central urban areas) had about a 10% higher prevalence of AD than did those living in coastal or suburban residences. The Chi-Square test demonstrated that this local difference was statistically significant before and after adjustment of major confounders such as parental AD history and parental education. The results of the logistic regression analysis showed a statistically significant association between several environmental factors (ventilation in winter, odor conditions and exposure to traffic smoke, and outdoor $PM_{10}/O_3$ pollution) and the prevalence of AD found by multivariate model after adjusting confounders. Conclusion: These results suggest that local differences in AD prevalence are significantly associated with outdoor environmental factors. Although there are likely to be other risk factors for AD, living in a polluted area and exposure to high levels of air pollutants can contribute to an increased risk of childhood AD.

The Impacts of Particulate Matter on Urban Activities in Jongno-Gu, Seoul (미세먼지가 도시민의 활동에 미치는 영향 - 서울시 종로구를 대상으로 -)

  • Moon, Hyeong-joo;Song, Jaemin
    • Journal of the Korean Regional Science Association
    • /
    • v.37 no.1
    • /
    • pp.29-44
    • /
    • 2021
  • Particulate matter(PM) is one of the leading causes of lung cancer. Recognizing its considerable risk to human health, people change their behaviors when a concentration level of PM is high. The impact of particulate matter on urban activities may vary depending on the lasting days of PM and PM matter alerts. In addition, the level of averting behavior may vary depending on the types and physical characteristics of urban activities and the degree of vulnerability to PM among people. Although the way people respond to PM may vary depending on these various factors, previous research evidence on this is very insufficient. Therefore, this study multilaterally analyzed the impact of PM on the urban activities in Jongno-gu, one of the CBD areas of Seoul. For this, we linked SKT's mobile phone signal data to land use data to extract the daily number of active people by urban activity types and ages. According to multiple regression analysis, the averting behavior varies depending on the type of urban activity, the physical characteristics of the place of activity(inside and outdoor), the lasting days of PM, PM alerts and the age of people. The results of this study can be used as basic data to policy makers who establish policies for adapting to air pollution policies by providing various effects of PM on the urban activities.

Use of Nitrogen Dioxide as Exposure Marker of Passive Smiking for Non-smoking Service-workers at Restaurants (음식점 비흡연 종업원의 간접흡연 노출량 지표로써 이산화질소 이용)

  • Won-Ho Yang;Young-Lim Kho;In-Kyu(Paul) Han;Chong-Min Lee;Moon-Shik Zong;Moon-Ho Chung
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2000
  • There is increasing evidence suggestion that passive smoking increases the risk of lung cancer and other disease, though the potential health effects of exposure to environmental tobacco smoke (ETS) is a controversial subject. Since smoking in restaurant is prevalent in Korea, the concern on passive smoking exposure of non-smoking service-workers has been requested. ETS exposure of non-smoking service-workers at restaurant was assessed because they hare spent their times in restaurant indoors. The purpose of this study was feasibility of nitrogen dioxide($NO_2$) as exposure marker of ETS. The results of the study were as follows; 1. Average $NO_2$ concentrations in indoor and outdoor t restaurants were 57.1ppb(${\pm}12.4$) and 54.29ppb(${\pm}9.54$), respectively. Comparing office-workers, service-workers at restaurants were exposured highly. 2. The personal $NO_2$ measurement as exposure marker of ETS could cause the exposure error because $NO_2$ can be generated by combustion appliances in indoor. 3. Service-workers spent their most time(86.6%) in indoor. Mean time spent at restaurant indoors and at home was 9.4 hours and 10.9 hours, respectively. 4. Personal $NO_2$ levels correlated with indoor $NO_2$ concentrations of restaurant (r=0.70) and of their home (r=0.52) rather than of outdoor $NO_2$ concentration of restaurant (r=0.35). The cause of personal $NO_2$ exposure of non-smoking service-workers were considered as smoking of guests and combustion appliance indoors. 5. personal $NO_2$ exposures were estimated using Monte-Carlo simulation and time-weighted model. Estimated personal $NO_2$ level was 47.25ppb(${\pm}8.3$).

  • PDF

Comparison of air pollution and the prevalence of allergy-related diseases in Incheon and Jeju City

  • Jeong, Su-Ho;Kim, Jeong-Hee;Son, Byong-Kwan;Hong, Seong-Chul;Kim, Su-Young;Lee, Geun-Hwa;Lim, Dae-Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.12
    • /
    • pp.501-506
    • /
    • 2011
  • Purpose: A high level of air pollutants can increase the number of patients with allergy-related diseases such as asthma and allergic rhinitis (AR). To analyze the association between air pollution and allergic disease, we investigated 2 areas in Korea: Incheon, an industrial area, and Jeju, a non-industrialized area. Methods: Second grade students at elementary schools (11 schools in Incheon and 45 schools in Jeju) were examined in a cross-sectional study. A questionnaire was used and a skin prick test was performed. The levels of $NO_2$, $CO_2$, $O_3$, particulate matter (PM) $PM_{10/2.5}$, formaldehyde, tVOCs, and dust mites in the classrooms and grounds were determined. Results: The levels of outdoor CO, $PM_{10}$, and $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The levels of indoor CO, $CO_2$, $PM_{10}$, $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The prevalence rates of AR symptoms at any time, AR symptoms during the last 12 months, diagnosis of rhinitis at any time, and AR treatment during the last 12 months were significantly higher in Incheon (P<0.01). The prevalence rate of wheezing or whistling at any time, and wheezing during the last 12 months were significantly higher in Incheon (P<0.01). Conclusion: We found that the children living in Incheon, which was more polluted than Jeju, had a higher rate of AR and asthma symptoms compared to children in Jeju. To determine the effect of air pollution on the development of the AR and asthma, further studies are needed.