• Title/Summary/Keyword: Out of the Dust

Search Result 488, Processing Time 0.031 seconds

The Accident Hazard and Properties of the Leakage Current on the Electrical Insulation by Pollution (전기 절연물의 오염에 따른 누설전류 특성 및 사고위험성 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.463-467
    • /
    • 2007
  • It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

Trace Metals Characterization of Respirable Dust during Yellow Sand Phenomena in Seoul Area (서울지역의 황사발생시 호흡성 분진 중 미량원소의 특성 평가)

  • 신은상;선우영
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • This research was carried out using Anderson air sampler which were set up on the roof of the Engineering College of Konkuk University at Hwayang-Dong, Kwangjin-Gu, Seoul from Aug. 1992 to foul. 1999. The results are as follows: The major component of yellow sand is soil particles based upon the observation that particles ranging from $3.3~7.0{\mu}m$ occupy 36~63%. It is certain that the increase of fine particles of respirable dust during yellow sand phenomenon in Seoul area affects the human body. The trace metals from natural sources like Al, Ca, Fe, K, Na, and Si show larger mass median diameter(MMD) values during yellow sand phenomenon than in normal situations while the values of MMD for Mn and Pb rarely changes. Noticeably, the changes in value of MMD of water soluble elements like ${NO_3}^{-}$ and ${SO_4}^{2}$ are 2.3 and 6.6 times higher during the yellow sand phenomenon compared to normal situations, respectively. This fact is regarded as decisive evidence showing that ${NO_3}^{-}$ and ${SO_4}^{2}$ in the air are attached to yellow sand and move together.

Effects of Allergen-related Asthmatic Airway Inflammation and Airway Hyperresponsiveness by Asian Sand Dust in Mice (생쥐에서 황사로 인한 항원관련 천식성 기도 염증과 기도 과민성에 미치는 영향)

  • Lim, Heung-Bin;Kim, Seung-Hyung
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.2
    • /
    • pp.121-129
    • /
    • 2010
  • This study was carried out to investigate whether asian yellow sand dust (AS) has promoting effects of allergen-related airway inflammation and airway hyperresponsiveness, because the number of patient with allergic asthma and atopy, and with chronic bronchial inflammation and pneumonia have increased steadily in the cities of Korea. The appearance of AS collected was all round and flat, and the diameter was mostly below about 5 ${\mu}m$. When mice were treated with AS suspension by intratracheal instillation combined with ovalalbumin(OVA) sensitization chronically, the level of serum L-lactate dehydrogenase (LDH), IgE and histamine, and respiratory resistance was increased. Intratracheal instillation of AS and OVA also enhanced infiltration of eosinophils in the bronchoalveolar lavage fluid (BALF), IgE and eotaxin expression, and T helper type 2 cell derived cytokines of interleukin (IL)-4, IL-13 and IL-5 as major contributors to allergy and asthma. These results indicate that AS elevates allergen-related airway inflammation and airway hyperresponsiveness in mice and may play an important role in the aggravation of respiratory diseases in Korea.

Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers (강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석)

  • Jang, Dong-hwa;Kwon, Kyeong-seok;Kim, Jong-bok;Kim, Jung-kon;Yang, Ka-young;Choi, Sung-min;Jang, YuNa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

Seasonal Dust Concentration and Characteristics of Windowless Broiler Building (무창 육계사의 계절별 먼지 농도와 특성 연구)

  • Choi H. C.;Yeon G. Y.;Song J. I.;Kang H. S.;Kwon D. J.;Yoo Y. H.;Barroga A. J.;Yang C. B.;Chun S. S.;Kim Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.197-206
    • /
    • 2005
  • This study was carried out to investigate the concentration and characteristics of dust originating from windowless broiler building in each season. 12.0m width and 46m tenth with side wall height of 3.0m was investigated and capacity was 12,800 birds at a stock density of 23.2 birds per square meter. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10{\mu}m(PM10),\;2.5{\mu}m (PM2.5),\;and\;1{\mu}m(PM1)$ were measured at 30-minute intervals. On the basis of broiler age, the average dust concentration in summer in TSP as follows: 1,229 904.5 558.8 and $1,053{\mu}g/m^3$ on the broilers' first to fourth week of age, respectively. But during winter, the average dust concentration showed an increasing pattern, as follows: 465.4, 1,401, 4,497, 5,097 and $6,873{\mu}g/m^3$ on the broilers' first to fifth week of age, respectively. The maximum dust concentration of $11,132{\mu}g/m^3$ was observed on the fifth week. On a daily basis, the maximum dust concentration during summer was detected in early morning, and the minimum in the afternoon. The aerial dust particle size of $0.05\~0.35{\mu}m$ was the highest in number. But on volume basis, particle size of 16~99 un had the largest percentage in the broiler house. Crude protein of the dust $(42.8\~65.2\%)$, on dry matter basis, was higher than that $(20.5\~24.5\%)$ fed to the broilers. Heavy metal concentration of the dust also had high levels compared with that of the feed.

  • PDF

Afforestation Effect Analysis Using MODIS Imagery: Yulin, Shaanxi, China As a Case Study (MODIS 영상을 이용한 중국 산시성 위린시의 조림 효과 분석)

  • Jang, Hyo-Seon;Kim, Sang-Pil;Kim, Mi-Kyeong;Sohn, Hong-Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.1007-1013
    • /
    • 2015
  • Desertification in China, one of the source regions of yellow dust, has been worsen by industrialization and extreme land development, which increases the damage caused by yellow dust in Korea. Because the yellow dust from China affects not only their own country, but also neighboring countries, it is becoming an international problem, and China has been started afforestation projects to prevent excessive desertification with the help of the international community. However, it is only possible for identifying the results of afforestation projects to check afforestation result reports from National Bureau of Statistics of China, which makes it difficult to check out tangible results. Therefore, this study was conducted by using remote sensing technique for monitoring afforestation status of Yulin, shaanxi, China. in which an afforestation project has been carried out steadily. MODIS imagery was used as remote sensing data and it was confirmed that vegetation has been increased through vegetation indices from 2000 to 2014 and afforestation areas were estimated as same trend of ground reference data.

Four Pollution and Safe Measure in Building Demolition (구조물폭파공법 시공시 발파공해 안전대책 - 소음.진동.분진.비석공해를 중심으로 -)

  • 안명석
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.3
    • /
    • pp.91-104
    • /
    • 1993
  • This paper is on the current and prospect of the most advanced explosive technics, special explosive technics. Futhermore, utmost needed and utmost centered interesting basic theory, struction explosive demolition is descirbed with counter Plan on the Problems of carrying out example and cuf out of it. Specified description noted on the four pollution especially noisy vibration, dust and disperse pollution with comprehensive counter plan. Although it has some insufficiency. I expect my paper will be to advance the explosive technics.

  • PDF

Process Technology of the Direct Separation and Recovery of Iron and Zinc Metals Contained in High Temperature EAF Exhaust Gas

  • Furukawa, Takeshi;Sasamoto, Hirohiko;Isozaki, Shinichi;Tanno, Fumio
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.393-397
    • /
    • 2001
  • The innovatory process, that is the direct separation and recovery of the iron and zinc metals contained in the high temperature exhaust gas generated from the electric arc furnace fer the inn scrap melting and/or the dust treatment, has been proposed. This proposed process consists of the moving coke bed filter that is directly connected to the electric furnace, and the following heavy metal condenser. The exhaust gas passes through the filter and the condenser right after exhausting from the electric furnace. The moving coke bed filter is being controlled at about 1000℃ and collects iron and slag components contained in the high temperature exhaust gas. Heavy metals such as zinc and lead pass through the filter as vapor. Based on the thermodynamic considerations, the iron oxide and the zinc oxide are reduced in the filter. The solution loss reaction rate is comparatively low at about 1000℃ in the coke bed filter by the analysis using the mathematical simulation model. The heavy metal condenser is installed in the position after the coke bed filter, and rapidly cools the gas from about 1000℃ to 450℃ by a full of the cooling medium like the solid ceramic ball in addition to the cooling from the wall. The zinc and lead vapor condense and separate f개m the gas in a liquid state. The investigation of the characteristics of the exhaust gas of the commercial electric arc furnace, the fundamental experiments of the laboratory scale and the bench scale ensured the formation of this proposed process. A small-scale pilot plant examination is carrying out at present to confirm the formation of the process. It is certain that the dust generation of the electric arc furnace is extremely decreased, and it can save the energy consumption of usual dust treatment processes by the realization of this process.

  • PDF

Density Distributions of Metallic Compounds in Particulate Matters (粒子狀 物質中 金屬成分의 密度分布)

  • 허문영;김형춘;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.9-18
    • /
    • 1986
  • For identification and apportionment of sources emitting particulate matters in environment, the multi-elemental characterization of size-density fractionated particulate matters was carried out. Eight types of samples were tested; soil, flyash released from burning of bunker-Coil, diesel oil, coal, and soft coal, urban road-way dust, urban dust fall, and airborne particulate matter. The fractions of particulate matters obtained by heavy liquid separation methos with a series of dichloromethane-bromoform were then analyzed using atomic absorption spectrophotometry for Ni, Cr, Cu, An, Fe, Al, and Mg. Each sample showed a different concentration profile as a function of density, and a number of useful conclusions concerning characterization of elemental distribution were obtained. From the density distributions of elements in soil, the maximum value was found for all elements in the density range of 2.2 $\sim 2.9g.cm^{-3}$, including the density of $SiO_2$. However, the distribution of metallic compounds with the density lower than $2.2g.cm^{-3}$ was prevalent in urban roadway dust, urban dust fall, and airborne particulate matter. And the density distribution curves of these urban dusts also have the higher distribution at the density of 2.2 - 2.9g.cm^{-3}$, including the density of wind-blown silica. This tendency generally was prevalent in the natural source elements, such as Al, Fe, Mn, and Mg. The maximum values were found in the density ranges of 1.3 $\sim 2.2g.cm^{-3}$ from the density distribution of elements in oil fired flyash. These distributions of anthropogenic source elements, such as Zn, Ni, Cu, and Cr were higher predominately than those of natural source elements. And the higher distribution was found in the density range of $2.2 \sim 2.9g.cm^{-3}$ from the density distribution of elements in coal and soft-coal fired flyash. These distributions showed similar patterns to soil. But anthropogenic source elements somewhat predominated at the density ranges of $1.3 \sim 2.2g.cm{-3} and 2.9g.cm^{-3}$ to soil. Therefore the higher distribution of anthropogenic source elements in the density ranges of $1.3 \sim 2.2g.cm^{-3} and 2.9g.cm^{-3}$ was considered as anthropogenic origin.

  • PDF

Development of the Quick Exhaust Valve to Blowing the Intake Filter for the Thermal Power Plant (화력발전소 흡입필터 세정용 급속 배기 밸브의 개발)

  • Jeong, C.S.;Lee, H.U.;Jeong, Y.M.;Lee, C.D.;Yang, S.Y.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.548-552
    • /
    • 2010
  • The air suction filter of the power plant decrease the dust and impurities of suction air that reduce the life and efficiency of the boiler. The suction efficiency of the air filter falls with the dust and impurities when the time of use comes to be long. Therefore, the various contaminant of the filter must remove periodically. This paper presents a developed quick exhaust valve to use in the thermo-electric power plant. to removing contaminants on the filter, the blowing is done shortly by air pressure. The Air flowed out to the out side from the inside of the filter. The performance test of the developed valve is done by making a test-bench according to JIS and KS standards. The efficiency is found higher than the existing related valve.