• Title/Summary/Keyword: Osseointegrated Implant

Search Result 131, Processing Time 0.02 seconds

Recent Advances of Osseointegrated Implants Removal (골유착된 임프란트 제거의 최신지견)

  • Kim, Nam Yoon
    • The Journal of the Korean dental association
    • /
    • v.54 no.4
    • /
    • pp.258-273
    • /
    • 2016
  • In spite of appropriate treatment of peri-implantitis, the peri-implant bone loss was keep going, the clinician should remove the osseointegrated implant. the conventional methods are like a extraction of natural teeth, and use of trephine drills. In these days, many exclusive instruments are invented by implant companies. these instruments can make easy, least invasive, less traumatic removal of osseointegrated implants. In generally peri-implant bone loss progress steadily less sign and symptoms that the patient do not want to remove their implants. However, the failure of dental implant is big burden to clinicians and also patients. In the dental implant treatment, there is no 'failure' but only is 'replacement' or 'change'.

  • PDF

CLINICAL STUDY ON SURVIVAL RATE OF OSSEOINTEGRATED IMPLANTS (골유착성 치과 임플란트의 생존율에 관한 임상적 연구)

  • Choi, Ji-Yeon;Koh, Se-Wook;Ryu, Hwun-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.306-313
    • /
    • 2009
  • Objectives: The aim of the present review was to evaluate survival rate and various factors associated with survival of osseointegrated implants. Patients and methods: The clinical comparisons were performed to evaluate survival rate of 794 endosseous implants that had been inserted between 2004 through 2008 in relation to sex and age of patients, position of implant, implant system and surface characteristics, length and diameter of implant, and bone graft technique. Results: The survival rate of implant was 94.3% in posterior area of maxilla and 98.6% in posterior area of mandible by position of implant, a statistically significant difference. As to diameter of implant, survival rate was 98.4% between the 4.0 and 4.5 mm and 75.0% in larger than 5.0 mm, that was statistically significant difference. There was a statistically significant difference regard to bone graft and surgical technique. The implant survival rate was 89.0% in a placement site which performed sinus lifting, and in case of implant placement with guided bone regeneration technique and without bone grafting was 97.6% and 100% each. Conclusion: According to these findings, this study establishes a relationship between survival rate of implant and position, surface characteristics, diameter of implant and bone graft technique.

A STUDY ON THE ELASTIC DEFORMATION AND STRESS DISTRIBUTION OF THE MANDIBLE WITH OSSEOINTEGRATED IMPLANT PROSTHESES USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (골유착성 임플랜트 보철물 장착시 하악골의 탄성변형 및 응력분포에 관한 삼차원 유한요소법적 연구)

  • Kim, Yong-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.203-244
    • /
    • 1998
  • The human mandible is always under the condition of loading by the various forces extorted by the attached muscles. The loading is an important condition of the stomatognathic system. This condition is composed of the direction and amount of forces of the masticatory muscles, which are controlled by the neuromuscular system, and always influenced by the movement of both opening and closing. Mandible is a strong foundation for the teeth or various prostheses, nevetheless it is a elastic body which accompanies deformation by the external forces on it. The elastic properties of the mandible is influenced by the various procedures such as conventional restorative treatments, osseointegrated implant treatments, reconstructive surgical procedures and so forth. Among the treatments the osseointegrated implant has no periodontal ligaments, which exist around the natural teeth to allow physiologic mobility in the alveolar socket. And so around the osseointegrated implant, there is almost no damping effect during the transmission of occlusal stress and displacements. If the osseointegrated implants are connected by the superstructure for the stabilization and effective distribution of occlusal stresses, the elastic properties of mandible is restricted according to the extent of 'splinting' by the superstructure and implants. To investigate the change of elastic behaviour of the mandible which has osseointegrated implant prosthesis of various numbers of implant installment and span of superstructre, a three dimensional finite element model was developed and analyzed with conditions mentioned above. The conclusions are as follows : 1. The displacements are primarily developed at the area of muscle attachment and distributed all around the mandible according to the various properties of bone. 2. The segmentation in the superstructure has few influence on the distribution of stress and displacement. 3. In the load case of ICP, the concentration of tensional stress was observed at the anterior portion of the ramus($9.22E+6N/m^2$) and at the lingual portion of the symphysis menti($8.36E+6N/m^2$). 4. In the load case of INC, the concentration of tensional stress was observed at the anterior portion of the ramus($9.90E+6N/m^2$) and the concentration of tensional stress was observed at the lingual portion of the symphysis menti($2.38E+6N/m^2$)). 5. In the load case of UTCP, the relatively high concentration of tensional stress($3.66E+7N/m^2$) was observed at the internal surface of the condylar neck.

  • PDF

STRESS ANALYSIS WITH NONLINEAR MODELLING OF THE LOAD TRANSFER CHARACTERISTICS ACROSS THE OSSEOINTEGRATED INTERFACES OF DENTAL IMPLANT

  • Lee Seung-Hwan;Jo Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.267-279
    • /
    • 2004
  • A modelling scheme for the stress analysis taking into account load transfer characteristics of the osseointegrated interfaces between dental implant and surrounding alveolar bone was investigated. Main aim was to develop a more realistic simulation methodology for the load transfer at the interfaces than the prefect bonding assumption at the interfaces which might end up the reduced level in the stress result. In the present study, characteristics of osseointegrated bone/implant interfaces was modelled with material nonlinearity assumption. Bones at the interface were given different stiffness properties as functions of stresses. Six different models, i.e. tens0, tens20, tens40, tens60, tens80, and tens100 of which the tensile moduli of the bones forming the bone/implant interfaces were specified from 0, 20, 40, 60, 80, and 100 percents, respectively, of the compressive modulus were analysed. Comparisons between each model were made to study the effect of the tensile load carrying abilities, i.e. the effectivity of load transfer, of interfacial bones on the stress distribution. Results of the present study showed significant differences in the bone stresses across the interfaces. The peak stresses, however, were virtually the same regardless of the difference in the effectivity of load transfer, indicating the conventional linear modelling scheme which assumes perfect bonding at the bone/implant interface can be used without causing significant errors in the stress levels.

A STUDY ON ORAL SENSORY FUNCTION IN THE IMPLANT-SUPPORTED PROSTHESES WEARERS (치과 임플랜트 보철 장착자의 구강 감각 기능에 관한 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.215-232
    • /
    • 1991
  • In this study, oral sensory function in the osseointegrated root form implant-supported prostheses wearers was estimated by measuring occlusal tactile perception threshold of thickness and sensibility threshold against lateral static loading, and comparing with normal dentition subjects and complete denture wearers group. Osseointegrated root form implants seemed to be restored in the sensation to some extent, and so, dental implants restored edentulous patients in a wide meaning. Conclusions were summarized as following. 1. Occlusal tactile perception threshold of thickness was highest in complete denture wearers group, following by implant-supported prostheses wearers group, normal dentition subjects group. 2. In the implant-supported prostheses wearers group, occlusal tactile perception threshold of opposing artificial teeth case was higher than of opposing natural or opposing implantsupported teeth case. 3. Sensibility threshold against lateral loading of complete denture wearers and implantsupported prostheses wearers group was higher than that of normal dentition subject group. 4. In the implant-supported prostheses group, sensibility threshold against lateral loading was not significantly different between upper and lower jaws. 5. In occlusal tactile perception threshold of thickness and sensibility threshold against lateral loading test, there was no regularity among values of each tooth, and no significant difference between anterior and posterior teeth as well.

  • PDF

A HISTOLOGICAL STUDY OF SURROUNDING BONE TISSUE REACTION TO HYDROXY APATITE COATED DENTAL IMPLANT (Hydroxy Apatite가 피복된 치과매식체의 주위골조직 반응에 관한 조직학적 연구)

  • Song, Joon-Ki;Hur, Sung-Joo;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.23-34
    • /
    • 1991
  • Even if we can recover the function of mastication, pronunciation and esthetic using the fixed or removable prosthesis in the loss of teeth or hard tissue in the oral cavity, we use several kinds of implants in order to solve the problem which can be occured when we can't install the denture because of excessive bone resolution or psychlogical affairs. At present Titanium implant plays a major role in this field and has osseointegrated. And the study on the modern material is going on, that result in developing and using the implant which is coated with HA, bone induced material. In this, I studied histologically the change of the bone tissue which is occured when three kinds of HA coated implants. Such as Integral, Sustain, Biovent implanted into mandible of dog and got a 8-weeks healing period. I got the conclusion as follows: 1. Most of the implant which is covered with serveral kinds of HA coating implant in bone after 8 weeks being implanted and has osseointegrated, partially converted into the connective tissue. 2. Biovent formed the connective tissue in the perforated area of inferior alveolar canal and has osseointegrated.

  • PDF

A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE (골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석)

  • Jeong Chang-Mo;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

PROSTHETIC REHABILITATION OF THE PARTIALLY EDENTULOUS PATIENT BY USING OSSEOINTEGRATE IMPLANT AFTER REMOVAL OF AMELOBLASTOMA (법랑아세포종 제거후의 Implant보철수복 증례)

  • Ahn, Sang-Hun;Kim, Jong-Pil;Jo, Byung-Woan;Ahn, Jye-Jynn
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.95-102
    • /
    • 1997
  • Ameloblastoma is the most agrressive ofht odontogenic tumors and it arises from the dental lamina or the derivatives of lamina. Ameloblastoma is a benign but locally invasive neoplasm consisting of proliferating odontogenic epithelium lying in a fibrous stroma. Usually the ameloblastomas are diagnosed in the forth and fifth decardes. Over 80% of them occur in the mandible, the remainder in the maxilla. The preferred treatment for ameloblastoma is radical excision, conserving(when possible. the inferior border of the mandible. The functional and esthetic rehabilitation of the partially edentulous patient may prevent the remaining structures from supporting conventional prosthetic treatment. Patients with long edentulous spans, malpositioned teeth, residual ridges defects and high muscle attachments may be offered an osseointegrated fixed prosthesis. Osseointegrated dental implants provide a viable alternative of tooth replacement. This is a case report of 16 year old female with ameloblastoma. We treated patient with radical excision, conserving the inferior border of the mandible and allogenous bone graft. The defected residual ridge area was reconstructed implants(Steri-Oss Implant System). the result was satisfactory.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS (임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석)

  • Cho, Chul;Shin, Sang-Wan;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF