• Title/Summary/Keyword: Oscillometry

Search Result 12, Processing Time 0.032 seconds

Pulmonary Functions and Inflammatory Biomarkers in Post-Pulmonary Tuberculosis Sequelae

  • Shanmugasundaram, Kumar;Talwar, Anjana;Madan, Karan;Bade, Geetanjali
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.2
    • /
    • pp.175-184
    • /
    • 2022
  • Background: Post-tuberculosis (TB) sequelae is a commonly encountered clinical entity, especially in high TB burden countries. This may represent chronic anatomic sequelae of previously treated TB, with frequent symptomatic presentation. This pilot study was aimed to investigate the pulmonary functions and systemic inflammatory markers in patients with post-TB sequelae (PTBS) and to compare them with post-TB without sequelae (PTBWS) participants and healthy controls. Methods: A total of 30 participants were enrolled, PTBS (n=10), PTBWS (n=10), and healthy controls (n=10). Pulmonary function tests included spirometry and measurement of airway impedance by impulse oscillometry. Serum levels of matrix metalloproteinase (MMP)-1, transforming growth factor-β, and interferon-γ were estimated. Results: Slow vital capacity (SVC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/FVC, and peak expiratory flow were significantly lower in PTBS as compared to controls. SVC and FEV1 were significantly less in PTBS as compared to PTBWS. Total airway impedance (Z5), total airway resistance (R5), central airway resistance (R20), area of reactance (Ax), and resonant frequency (Fres) were significantly higher and respiratory reactance at 5 and 20 Hz (X5, X20) were significantly lower in PTBS as compared to PTBWS. Spirometry parameters correlated with impulse oscillometry parameters in PTBS. Serum MMP-1 level was significantly higher in PTBS as compared to other groups. Conclusion: Significant pulmonary function impairment was observed in PTBS, and raised serum MMP-1 levels compared with PTBWS and healthy controls. Follow-up pulmonary function testing is recommended after treatment of TB for early diagnosis and treatment of PTBS.

Reference values for respiratory system impedance using impulse oscillometry in school-aged children in Korea (학동기 소아에서 impulse oscillometry system로 측정한 폐기능 정상치)

  • Wee, Young Sun;Kim, Hyoung Yun;Jung, Da Wun;Park, Hye Won;Shin, Yoon Ho;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.862-867
    • /
    • 2007
  • Purpose : The impulse oscillometry (IOS) is applicable to young children because it requires minimal cooperation and a non-invasive method to measure the mechanics of respiratory system. This study aimed to develop the reference values in school-aged children in Korea, using IOS which is a modification of forced oscillation technique (FOT). Methods : Measurements were performed in 92 previously untrained healthy children, aged 7 to 12 years old, using IOS. We analyzed the relationships between the data about their age, height, weight, body surface area (BSA), body mass index (BMI) and the result of IOS using the linear regression test. Results : The success rate of IOS was 92.4%. Stepwise multiple regression of resistance of respiratory system (Rrs) and reactance of respiratory system (Xrs) in natural form for age, height, weight, BSA, BMI showed that height was the most significant predictor and altogether of 5 variables explained the Rrs and Xrs most. Our regression equations at multiple frequencys were comparable to published reference values, especially about the Rrs obtained at 5 Hz. Conclusion : IOS is a feasible method to measure the respiratory resistance in untrained children. We got the reference values using IOS and it seems to be useful to diagnose a variety of respiratory diseases.

A Comparison of Ultrasonic Doppler and Oscillometric Methods in Systemic Blood Pressure Measurement of Dogs

  • Gang, Ho-min;Song, Joong-Hyun;Cho, Kyu-Woan;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.321-324
    • /
    • 2016
  • The present study compared two indirect blood pressure methods at thoracic limb, pelvic limb, and coccygeal sites. For measurement of blood pressure, 48 client-owned dogs in a clinical setting were used. When comparing the results obtained by doppler and oscillometric methods, there were significant differences in blood pressure of the thoracic and pelvic limbs. The Doppler machine produced significantly higher blood pressure value than oscillometry measured at thoracic and pelvic limbs. The difference in blood pressure between the two methods was not significant when measured in the tail. Comparison of blood pressure measured at three different sites by doppler, blood pressure measured at pelvic limb was higher than at thoracic limb and tail. In case of oscillometry, there were no significant differences between the three sites. The results of this study indicate that mechanical and positional differences were existed in blood pressure measurements at the canine thoracic limb, pelvic limb and tail.

The Application of Impulse Oscillometry (IOS) in the Workers Who had been Exposed to Inorganic Dust Induced Early Airway Obstruction (Impulse Oscillometry (IOS)를 이용한 무기분진 노출자에서의 기도폐쇄 연구)

  • Lee, Joung-Oh;Lee, You-Lim;Choi, Byung-Soon;Lee, Hong-Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.431-437
    • /
    • 2011
  • Background: We tried to examine the small airway diseases which can be found early, in workers exposed to inorganic dusts. This is measured in normal breath by using the impulse oscillometry (IOS). Methods: The Pulmonary function test (forced vital capacit [FVC], forced expiratory volume in one second [$FEV_1$], forced expiratory flow between 25% and 75% of vital capacity [$FEF_{25-75}$]), IOS resistance (Rrs at 5, 10, 15, 20, 25, 35 Hz) and reactance (Xrs at 5, 10, 15, 20, 25, 35 Hz) were measured for 454 workers. The subjects were classified into 173 workers of normal (38.1%) and 281 patients with pneumoconiosis (61.9%). Results: There were significant differences between normal and patients with FVC ($3.82{\pm}0.61$ vs. $3.53{\pm}0.56L$), $FEV_1$ ($2.67{\pm}0.63$ vs. $2.35{\pm}0.48L$), and $FEF_{25-75}$ ($1.88{\pm}0.95$ vs. $1.47{\pm}0.80L/sec$) between groups (p<0.05). And as for IOS, there was no significant difference in resistance (Rrs) (p>0.05), and there were significant differences between normal and patients with reactance (Xrs) 15 Hz ($0.003{\pm}0.05$ vs. $-0.006{\pm}0.04kPa/L/s$), 20 Hz ($0.043{\pm}0.05$ vs. $0.031{\pm}0.04kPa/L/s$), and 35 Hz ($0.141{\pm}0.05$ vs. $0.131{\pm}0.05kPa/L/s$) between groups (p<0.05). Conclusion: We could find out that 15 Hz, 20 Hz, and 35 Hz values of reactance were significantly influenced by pneumoconiosis. When usefulness and reproducibility to carry out the IOS are considered, it is thought that in future work will be required to draw the reference values for normal Korean persons.

Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

  • Ji Soo Choi;Se Hyun Kwak;Min Chul Kim;Chang Hwan Seol;Seok-Jae Heo;Sung Ryeol Kim;Eun Hye Lee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.3
    • /
    • pp.368-377
    • /
    • 2024
  • Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 ≥0.43, resistance at 20 Hz (R20) ≥0.234, R5-R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤-0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 ≤-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate-to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809. Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable tools for predicting bronchiectasis severity.

Oscillometry-Defined Small Airway Dysfunction in Patients with Chronic Obstructive Pulmonary Disease

  • Amit K. Rath;Dibakar Sahu;Sajal De
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.165-175
    • /
    • 2024
  • Background: The prevalence of small airway dysfunction (SAD) in patients with chronic obstructive pulmonary disease (COPD) across different ethnicities is poorly understood. This study aimed to estimate the prevalence of SAD in stable COPD patients. Methods: We conducted a cross-sectional study of 196 consecutive stable COPD patients. We measured pre- and post-bronchodilator (BD) lung function and respiratory impedance. The severity of COPD and lung function abnormalities was graded in accordance with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines. SAD was defined as either difference in whole-breath resistance at 5 and 19 Hz > upper limit of normal or respiratory system reactance at 5 Hz < lower limit of normal. Results: The cohort consisted of 95.9% men, with an average age of 66.3 years. The mean forced expiratory volume 1 second (FEV1) % predicted was 56.4%. The median COPD assessment test (CAT) scores were 14. The prevalence of post-BD SAD across the GOLD grades 1 to 4 was 14.3%, 51.1%, 91%, and 100%, respectively. The post-BD SAD and expiratory flow limitation at tidal breath (EFLT) were present in 62.8% (95% confidence interval [CI], 56.1 to 69.9) and 28.1% (95% CI, 21.9 to 34.2), respectively. COPD patients with SAD had higher CAT scores (15.5 vs. 12.8, p<0.01); poor lung function (FEV1% predicted 46.6% vs. 72.8%, p<0.01); lower diffusion capacity for CO (4.8 mmol/min/kPa vs. 5.6 mmol/min/kPa, p<0.01); hyperinflation (ratio of residual volume to total lung capacity % predicted: 159.7% vs. 129%, p<0.01), and shorter 6-minute walk distance (367.5 m vs. 390 m, p=0.02). Conclusion: SAD is present across all severities of COPD. The prevalence of SAD increases with disease severity. SAD is associated with poor lung function and higher symptom burden. Severe SAD is indicated by the presence of EFLT.

A comparison between impulse oscillometry system and spirometry for spirometry for detecting airway obstruction in children (소아의 기도 폐쇄 평가에서 impulse oscillometry system과 폐활량 측정법의 비교)

  • Hur, Hae Young;Kwak, Ji Hee;Kim, Hyoung Yun;Jung, Da Wun;Shin, Yoon Ho;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.842-847
    • /
    • 2008
  • Purpose : Measurement of forced expiratory volume in 1 second ($FEV_1$) is usually difficult to obtain in children under six years of age because it requires active cooperation. This study evaluates the sensitivity of impulse oscillometry system (IOS) parameters for detecting airway obstruction in comparison with $FEV_1$. Methods : We studied 174 children who performed the lung function and methacholine challenge tests to diagnose asthma by IOS and spirometry. Children were divided into two subgroups according to their $PC_{20}$, which is a parameter for bronchial sensitivity. We compared IOS parameters with $FEV_1$ at the baseline, post-methacholine challenge, and evaluated their correlation. Results : At the baseline, reactance at 5 Hz (X5) and resistance at 5 Hz (R5) significantly differed between the $PC_{20}$ positive ($PC_{20}{\leq}16mg/mL$) group and $PC_{20}$ negative ($PC_{20}$ >16 mg/mL) group; however, $FEV_1$, $FEV_1$ % predicted, $FEV_1_-Zs$ (Z score) did not differ. $FEV_1$ is correlated with X5 (r=0.45, P<0.01) and R5 (r=-0.69, P<0.01). $FEV_1_-Zs$ is also correlated with X5_Zs (r=-0.26, P<0.01) and R5_Zs (r=-0.31, P<0.01). After the methacholine challenge test, dose-response slopes in $FEV_1$ and X5 significantly differed between the two subgroups (P<0.05). Conclusion : IOS parameters were more discriminative than $FEV_1$ for detecting decreased baseline lung function between two subgroups and have a good correlation with $FEV_1$.

The Application of Impulse Oscillometry(IOS) in the Detection of Smoking Induced Early Airway Obstruction (Impulse Oscillometry(IOS)를 이용한 흡연자에서의 조기 기도폐쇄의 연구)

  • Kim, Youn-Seup;Kweon, Suk-Hoe;Song, Mi-Young;Yoo, Sun-Mi;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1030-1039
    • /
    • 1997
  • Background : Impulse Oscillometry is a noninvasive and effort-independent test used to characterize the mechanical impedance of the respiratory system. The clinical potential of the IOS is rapid and demands only passive cooperation which makes it especially appealing for children, for epidemiologic surveys and for conditions in which quiet breathig instead of forced expiratory maneuvers are preferred. However, several studies have shown conflicting results that the role of IOS about detection of smoking induced small airway diseases or early airway obstruction Methods : Study was to evaluate the clinical ability of the IOS to detect about smoking induced early airway obstruction in persons with normal spirometry test. Respiratory asymptomatic study groups were formed that one is non-smoking group, another is smoking group. Results : The parameters of spirometry were not significantly differences between non-smoking group and smoking group. Among the parameters of IOS, total resistance(non-smoking group : smoking group=$2.22{\pm}1.20$ : $2.58{\pm}1.71$), peripheral resistance($1.25{\pm}0.62$ : $1.47{\pm}0.10$), bronchial compliance($0.44{\pm}0.12$ : $0.47{\pm}0.16$) were not statistically significant different (p<0.05), but central resistance and lung compliance were not statistically significant different (unit ; resistance=hPa/l/s, compliance=l/hPa). Resistance(Rrs) was not statistically significant different with changes of frequences(5, 10, 15, 20, 25, 30, 35Hz), but Reactance(Xrs) was statistically significant different with low frequences that X5(non-smoking group : smoking group=$-0.62{\pm}0.28$ : $-0.76{\pm}0.48$, p<0.001) and X10($-0.06{\pm}0.19$ : $-0.15{\pm}0.33$, p<0.013) (unit; hPall/s, $hPa{\cong}cmH_2O$). Conclusion : Impulse oocillometer(IOS) is clinically available method to detect about smoking induced early airway obstruction. And clinically potential parameters of IOS were considers that total resistance, peripheral resistance, bronchial resistance, and reactance of low frequency at 5Hz, 10Hz.

  • PDF

The Effect of Exercise on Pulmonary Function (운동이 폐기능에 미치는 영향)

  • Park, Jae-Seuk;Kim, Youn-Seup;Choi, Eun-Kyoung;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl;Chun, Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.351-359
    • /
    • 1998
  • Background: The effects of exercise on pulmonary function are complex and have been the subject of many investigations. But, there has been disputes about the effect of exercise on spirometric parameters and there is no study about the effect of exercise on IOS(Impulse Oscillometry)parameters. IOS, a new method of pulmonary function test, is based on the relationship between the pressure and flow oscillation which is produced by applying sinusoidal pressure oscillation to the respiratory system via the mouth. Method: Fifty-nine young adults without respiratory symptoms were divided into three groups according to degree of exercise(hard exercise group: mean exercise time is over three hours per week at least for the last one month, light exercise group : between thirty minutes to three hours, nonexercise group : less than thirty minutes) and undertaken pulmonary function test(simple spirometry and IOS). Results: The effects of exercise on spirometric parameters; percentage of predictive value of forced vital capacity(FVC % pred) was higher in hard exercise group than nonexercise group(hard exercise group: $102.4{\pm}14.8$, nonexercise group: $93.7{\pm}9.9$, p=0.017), but there was no significant difference in percentage of predicted value of forced expiratory volume in one second(FEV 1 % pred) and percentage of predicted value of forced expiratory flow 50% (FEF 50% pred) between groups. The effects of exercise on IOS parameters: Reactance at 5Hz(X5) was significantly lower in hard exercise group than nonexercise group(hard exercise group: $-0.166{\pm}0.123hPa/1/s$, nonexercise group: $-0.093{\pm}0.036hPa/1/s$, p=0.006) but there was no significant difference in central resistance(Rc), peripheral resistance(Rp), resonance frequency(RF) and resistance at 5Hz, 20Hz between groups. Conclusion: Hard exercise increased FVC % pred on spirometric parameters and decreased reactance at 5Hz(X5) on IOS parameters.

  • PDF