Objective: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. Methods: In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (${\alpha}=0.05$). Results: In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Conclusions: Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.
Orthodontic treatment planning of cleft lip and palate requires consideration of the characteristic features, growth pattern and functional disorders related to cleft lip and palate patients. Tissue deficiencies and constriction of the scar tissue in surgically treated cleft lip and palate results in disturbance of maxillary growth and deficiency of midfacial region with anterior and posterior crossbite. These patients often present congenital missing of teeth, supernumerary teeth, malformed teeth, or ectopic position of teeth, which should be treated by orthodontic treatment by expanding upper arch followed by fixed appliance. Proper use of retainer and continuous follow-up is needed to prevent relapse after orthodontic treatment has finished. Also we have to pay attention to correct speech disorder which is caused by the velopharyngeal insufficiency.
This case reports describe a new approach to the use of polymers in orthodontics, using a fiber reinforced composite(FRC). FRC was successfully used in a periodontal splints, fiber post for endodontic use, orthodontic retainer and space maintainers, implant prosthesis, large span bridge, management of cracked tooth, anchorage reinforcement in orthodontics. FRC has highly favorable mechanical properties, and its strength-to-weight ratios is superior to those of most alloys. FRC has potential for use in many applications in dentistry and is expected to gain increasing application and popularity in dentistry. These case reports show that FRC is a promising anchorage reinforcement material for use in orthodontic practice.
전치부 공극의 치료법으로는 교정적인 폐쇄, 수술에 의한 방법, 보철에 의한 치료등의 방법이 있으며 이중 교정적인 폐쇄에 의한 치료법은 가장 보존적인 방법으로 많이 사용되고 있으나 그 치료이후의 보정에 많은 문제가 있었다. 저자등은 전치부 공극을 가진 3증례의 치료후 재발과정과 보정과정을 관찰한 결과 다음과 같이 요약할 수 있었다. 양 중절치가 서로 직접 연결되지 않는 보정장치의 사용은 영구보철물에 의한 경우에도 재발을 가져왔다. $\cdot$ 교정적으로 공극을 폐쇄한후, 순소대절제술, circumferential supracrestal fibrotomy 그리고 양 중절치가 서로 연결된 설측 부착 보정장치의 시행으로 좋은 유지 효과를 얻었다. 이상의 결과로 미루어 볼때 전치부 공극은 교정적 치료후, 순소대절제술, fibrotomy등을 시행한 후 반드시 양 중절치를 연결하는 고정성 보정 장치가 필요하다고 생각된다.
Objective: The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods: Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting in a total of six groups. Each stainless steel and fiber-reinforced composite group was comprised of six specimens. The three-point bending flexural test was conducted using a universal testing machine. ANOVA was used to assess differences in the maximum load and maximum stress according to the span length, material, and storage condition. Post-hoc comparisons were performed if necessary. Results: The maximum stress and maximum load were significantly (p < 0.001) associated with the span length, material, and storage condition. The significant interaction between the material and span length (p < 0.001) indicated the differential effects of the material for each span length on the maximum stress and maximum load, with the difference between materials being the highest for the maximum span length. Conclusions: Our findings suggest that fiber-reinforced composite retainers may be an effective alternative for orthodontic retention in patients with esthetic concerns or allergy to conventional stainless steel wires.
Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann-Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.
Objective: We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods: We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), $0.016{\times}0.022$-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results: Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions: Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers.
교정력을 가한 후 각기 다른 재료로 제작된 고정성 보정장치를 적용한 경우에 발생하는 치주조직의 재형성과 치유과정을 조직학적으로 관찰하기 위해 건강한 치주상태를 가진 네 마리의 유성견을 대상으로 최초 교정력이 200gm이 되도록 견인 스프링 (sentalloy closed coil $spring^{\circledR}$, Tomy Co., Japan)을 대상 치아에 결찰하여 1주일 간 교정력 을 가한 후 각각의 실험동물에 3가닥 호선인 0.018인치 $Dentaflex^{\circledR}$(Dentarum Co., Germany), 3가닥 호선인 0.020인치 $Dentaflex^{\circledR}$(Dentarum Co. Germany), 5가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를, 그리고 자가중합형 레진 접착제인 Superbond $C&B^{\circledR}$를 고정성 보정장치의 재료를 이용하여 보정장치를 접착한 군과 보정장치를 접착하지 않은 군으로 나누어 3주간 적용 후 희생하여 H-E 염색군, M-T 염색군으로 나누어 광학현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 0.0195인치 $Respond^{\circledR}$를 접착시킨 군은 0.018인치 $Dentaflex^{\circledR}$, 0.020인치 $Dentaflex^{\circledR}$, Superbond $C&B^{\circledR}$를 접착시킨 군에 비교할 때 압박측에서의 거대세포 침윤 감소와 긴장측에서의 신생골 형성 증가가 매우 두드러지게 나타났으며 치주인대는 형태와 배열에서 대부분 정상적인 소견을 보였다. 2. 실험 1군의 모든 실험대상에서 압박측 치조골 내부의 괴사골이 관찰되었고, 압박측과 긴장측 모두에서 치조골 표면의 골양조직 및 sharpey 섬유의 형성과 치주인대의 재형성 현상이 나타나는 것이 관찰되었다. 3. 실험 2군은 실험 1군에 비교하여 압박측에서 거대세포 침윤이 현저히 감소되었고 치주인대는 거의 정상적인 소견을 보였다. 긴장측에서는 수층의 골침착을 보이며 치주인대 측으로 골양조직과 골아세포가 구상으로 나타나는 활성화 소견을 보였다. 이상의 결과에서 더 여러 가닥이 꼬인 6가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를 보정장치로 적용한 경우가 다른 재료의 고정성 보정장치보다 더 활발한 신생골주 형성의 활성화 소견이 관찰되었으며 대조군과 유사한 배열과 형태를 보이는 정상적인 치주인대 섬유의 배열양상이 관찰되어 다른 재료들에 비교하여 치주조직의 초기 재형성 과정을 더 신속하게 유도하는 것으로 사료된다.
Kaat Verschueren;Amit Arvind Rajbhoj;Giacomo Begnoni;Guy Willems;Anna Verdonck;Maria Cadenas de Llano-Perula
대한치과교정학회지
/
제53권6호
/
pp.365-373
/
2023
Objective: To investigate the potential correlation between fixed orthodontic retention failure and several patient- and treatment-related factors. Methods: Patients finishing treatment with fixed appliances between 2016 and 2017 were retrospectively included in this study. Those not showing fixed retention failure were considered as control group. Patients with fixed retention failure were considered as the experimental group. Additionally, patients with failure of fixed retainers in the period of June 2019 to March 2021 were prospectively identified and included in the experimental group. The location of the first retention failure, sex, pretreatment dental occlusion, facial characteristics, posttreatment dental occlusion, treatment approach and presence of oral habits were compared between groups before and after treatment separately by using a Fisher exact test and a Mann-Whitney U test. Results: 206 patients with fixed retention failure were included, 169 in the mandibular and 74 in the maxillary jaws. Significant correlations were observed between retention failure in the mandibular jaws and mandibular arch length discrepancy (P = 0.010), post-treatment growth pattern (P = 0.041), nail biting (P < 0.001) and abnormal tongue function (P = 0.002). Retention failure in the maxillary jaws was more frequent in patients with IPR in the mandibular jaws (P = 0.005) and abnormal tongue function (P = 0.021). Conclusions: This study suggests a correlation between fixed retention failure and parafunctional habits, such as nail biting and abnormal tongue function. Prospective studies with larger study populations could further confirm these results.
Relapse following rotational movement of the tooth is a common problem in orthodontic practice. To overcome such relapse, many procedures have been advocated: prolonged retention, permanent retention, over-rotation, rotation of teeth at an early age, surgical procedures such as gingivectomy, redressement force, septotomy, et cetra. A 23-year-old woman presented with Angle's Class I malocclusion and extreme rotation of maxillary central incisors. After 15 months' active therapy, septotomy was performed on maxillary central incisors and Howley retainer was applicated for the purpose of overcoming rotational relapse. During the 1 year post-operative observation, negligible, if any, rotational relapse occurred.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.