• 제목/요약/키워드: Orthodontic retainer

검색결과 29건 처리시간 0.022초

Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial

  • Sobouti, Farhad;Rakhshan, Vahid;Saravi, Mahdi Gholamrezaei;Zamanian, Ali;Shariati, Mahsa
    • 대한치과교정학회지
    • /
    • 제46권2호
    • /
    • pp.104-110
    • /
    • 2016
  • Objective: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. Methods: In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (${\alpha}=0.05$). Results: In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Conclusions: Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.

선청성 구순구개열 환자의 장기적인 교정 치료 및 음성언어학적 고찰 (Long-term Orthodontic Treatment and Phonetic Assessment of a Congenital Cleft Lip and Palate Patient)

  • 홍지숙;김윤지;황용인;김대성;박양호
    • 대한구순구개열학회지
    • /
    • 제12권1호
    • /
    • pp.7-20
    • /
    • 2009
  • Orthodontic treatment planning of cleft lip and palate requires consideration of the characteristic features, growth pattern and functional disorders related to cleft lip and palate patients. Tissue deficiencies and constriction of the scar tissue in surgically treated cleft lip and palate results in disturbance of maxillary growth and deficiency of midfacial region with anterior and posterior crossbite. These patients often present congenital missing of teeth, supernumerary teeth, malformed teeth, or ectopic position of teeth, which should be treated by orthodontic treatment by expanding upper arch followed by fixed appliance. Proper use of retainer and continuous follow-up is needed to prevent relapse after orthodontic treatment has finished. Also we have to pay attention to correct speech disorder which is caused by the velopharyngeal insufficiency.

  • PDF

Fiber Reinforced Composite를 이용한 치료 증례 (Applications of Fiber Reinfored Composite in Dental Practice)

  • 조진형
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.23-27
    • /
    • 2006
  • This case reports describe a new approach to the use of polymers in orthodontics, using a fiber reinforced composite(FRC). FRC was successfully used in a periodontal splints, fiber post for endodontic use, orthodontic retainer and space maintainers, implant prosthesis, large span bridge, management of cracked tooth, anchorage reinforcement in orthodontics. FRC has highly favorable mechanical properties, and its strength-to-weight ratios is superior to those of most alloys. FRC has potential for use in many applications in dentistry and is expected to gain increasing application and popularity in dentistry. These case reports show that FRC is a promising anchorage reinforcement material for use in orthodontic practice.

전치부 공극의 치료후 재발에 관한 임상적 고찰 (CLINICAL STUDY ON THE RELAPSE OF DIASTEMA)

  • 박효상;성재현
    • 대한치과교정학회지
    • /
    • 제24권1호
    • /
    • pp.95-104
    • /
    • 1994
  • 전치부 공극의 치료법으로는 교정적인 폐쇄, 수술에 의한 방법, 보철에 의한 치료등의 방법이 있으며 이중 교정적인 폐쇄에 의한 치료법은 가장 보존적인 방법으로 많이 사용되고 있으나 그 치료이후의 보정에 많은 문제가 있었다. 저자등은 전치부 공극을 가진 3증례의 치료후 재발과정과 보정과정을 관찰한 결과 다음과 같이 요약할 수 있었다. 양 중절치가 서로 직접 연결되지 않는 보정장치의 사용은 영구보철물에 의한 경우에도 재발을 가져왔다. $\cdot$ 교정적으로 공극을 폐쇄한후, 순소대절제술, circumferential supracrestal fibrotomy 그리고 양 중절치가 서로 연결된 설측 부착 보정장치의 시행으로 좋은 유지 효과를 얻었다. 이상의 결과로 미루어 볼때 전치부 공극은 교정적 치료후, 순소대절제술, fibrotomy등을 시행한 후 반드시 양 중절치를 연결하는 고정성 보정 장치가 필요하다고 생각된다.

  • PDF

Comparison between fiber-reinforced polymers and stainless steel orthodontic retainers

  • Lucchese, Alessandra;Manuelli, Maurizio;Ciuffreda, Claudio;Albertini, Paolo;Gherlone, Enrico;Perillo, Letizia
    • 대한치과교정학회지
    • /
    • 제48권2호
    • /
    • pp.107-112
    • /
    • 2018
  • Objective: The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods: Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting in a total of six groups. Each stainless steel and fiber-reinforced composite group was comprised of six specimens. The three-point bending flexural test was conducted using a universal testing machine. ANOVA was used to assess differences in the maximum load and maximum stress according to the span length, material, and storage condition. Post-hoc comparisons were performed if necessary. Results: The maximum stress and maximum load were significantly (p < 0.001) associated with the span length, material, and storage condition. The significant interaction between the material and span length (p < 0.001) indicated the differential effects of the material for each span length on the maximum stress and maximum load, with the difference between materials being the highest for the maximum span length. Conclusions: Our findings suggest that fiber-reinforced composite retainers may be an effective alternative for orthodontic retention in patients with esthetic concerns or allergy to conventional stainless steel wires.

Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study

  • Sangalli, Linda;Savoldi, Fabio;Dalessandri, Domenico;Visconti, Luca;Massetti, Francesca;Bonetti, Stefano
    • 대한치과교정학회지
    • /
    • 제52권2호
    • /
    • pp.123-130
    • /
    • 2022
  • Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann-Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

  • Baysal, Asli;Uysal, Tancan;Gul, Nisa;Alan, Melike Busra;Ramoglu, Sabri Ilhan
    • 대한치과교정학회지
    • /
    • 제42권1호
    • /
    • pp.39-46
    • /
    • 2012
  • Objective: We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods: We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), $0.016{\times}0.022$-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results: Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions: Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers.

수종의 고정성 보정장치에 따른 유성견의 치주조직 반응 (Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs)

  • 조명훈;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.85-95
    • /
    • 2001
  • 교정력을 가한 후 각기 다른 재료로 제작된 고정성 보정장치를 적용한 경우에 발생하는 치주조직의 재형성과 치유과정을 조직학적으로 관찰하기 위해 건강한 치주상태를 가진 네 마리의 유성견을 대상으로 최초 교정력이 200gm이 되도록 견인 스프링 (sentalloy closed coil $spring^{\circledR}$, Tomy Co., Japan)을 대상 치아에 결찰하여 1주일 간 교정력 을 가한 후 각각의 실험동물에 3가닥 호선인 0.018인치 $Dentaflex^{\circledR}$(Dentarum Co., Germany), 3가닥 호선인 0.020인치 $Dentaflex^{\circledR}$(Dentarum Co. Germany), 5가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를, 그리고 자가중합형 레진 접착제인 Superbond $C&B^{\circledR}$를 고정성 보정장치의 재료를 이용하여 보정장치를 접착한 군과 보정장치를 접착하지 않은 군으로 나누어 3주간 적용 후 희생하여 H-E 염색군, M-T 염색군으로 나누어 광학현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 0.0195인치 $Respond^{\circledR}$를 접착시킨 군은 0.018인치 $Dentaflex^{\circledR}$, 0.020인치 $Dentaflex^{\circledR}$, Superbond $C&B^{\circledR}$를 접착시킨 군에 비교할 때 압박측에서의 거대세포 침윤 감소와 긴장측에서의 신생골 형성 증가가 매우 두드러지게 나타났으며 치주인대는 형태와 배열에서 대부분 정상적인 소견을 보였다. 2. 실험 1군의 모든 실험대상에서 압박측 치조골 내부의 괴사골이 관찰되었고, 압박측과 긴장측 모두에서 치조골 표면의 골양조직 및 sharpey 섬유의 형성과 치주인대의 재형성 현상이 나타나는 것이 관찰되었다. 3. 실험 2군은 실험 1군에 비교하여 압박측에서 거대세포 침윤이 현저히 감소되었고 치주인대는 거의 정상적인 소견을 보였다. 긴장측에서는 수층의 골침착을 보이며 치주인대 측으로 골양조직과 골아세포가 구상으로 나타나는 활성화 소견을 보였다. 이상의 결과에서 더 여러 가닥이 꼬인 6가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를 보정장치로 적용한 경우가 다른 재료의 고정성 보정장치보다 더 활발한 신생골주 형성의 활성화 소견이 관찰되었으며 대조군과 유사한 배열과 형태를 보이는 정상적인 치주인대 섬유의 배열양상이 관찰되어 다른 재료들에 비교하여 치주조직의 초기 재형성 과정을 더 신속하게 유도하는 것으로 사료된다.

  • PDF

Risk factors for orthodontic fixed retention failure: A retrospective controlled study

  • Kaat Verschueren;Amit Arvind Rajbhoj;Giacomo Begnoni;Guy Willems;Anna Verdonck;Maria Cadenas de Llano-Perula
    • 대한치과교정학회지
    • /
    • 제53권6호
    • /
    • pp.365-373
    • /
    • 2023
  • Objective: To investigate the potential correlation between fixed orthodontic retention failure and several patient- and treatment-related factors. Methods: Patients finishing treatment with fixed appliances between 2016 and 2017 were retrospectively included in this study. Those not showing fixed retention failure were considered as control group. Patients with fixed retention failure were considered as the experimental group. Additionally, patients with failure of fixed retainers in the period of June 2019 to March 2021 were prospectively identified and included in the experimental group. The location of the first retention failure, sex, pretreatment dental occlusion, facial characteristics, posttreatment dental occlusion, treatment approach and presence of oral habits were compared between groups before and after treatment separately by using a Fisher exact test and a Mann-Whitney U test. Results: 206 patients with fixed retention failure were included, 169 in the mandibular and 74 in the maxillary jaws. Significant correlations were observed between retention failure in the mandibular jaws and mandibular arch length discrepancy (P = 0.010), post-treatment growth pattern (P = 0.041), nail biting (P < 0.001) and abnormal tongue function (P = 0.002). Retention failure in the maxillary jaws was more frequent in patients with IPR in the mandibular jaws (P = 0.005) and abnormal tongue function (P = 0.021). Conclusions: This study suggests a correlation between fixed retention failure and parafunctional habits, such as nail biting and abnormal tongue function. Prospective studies with larger study populations could further confirm these results.

Septotomy를 행한 염전치의 교정치험예 (A CASE REPORT OF SEPTOTOMY OPERATED AFTER TREATMENT OF ROTATED TEETH)

  • 양원식;김영복;김종태
    • 대한치과의사협회지
    • /
    • 제16권11호통권114호
    • /
    • pp.849-856
    • /
    • 1978
  • Relapse following rotational movement of the tooth is a common problem in orthodontic practice. To overcome such relapse, many procedures have been advocated: prolonged retention, permanent retention, over-rotation, rotation of teeth at an early age, surgical procedures such as gingivectomy, redressement force, septotomy, et cetra. A 23-year-old woman presented with Angle's Class I malocclusion and extreme rotation of maxillary central incisors. After 15 months' active therapy, septotomy was performed on maxillary central incisors and Howley retainer was applicated for the purpose of overcoming rotational relapse. During the 1 year post-operative observation, negligible, if any, rotational relapse occurred.

  • PDF