• Title/Summary/Keyword: Orthodontic miniscrews

Search Result 45, Processing Time 0.027 seconds

Three dimensional finite element analysis of continuous and segmented arches with use of orthodontic miniscrews (교정용 미니스크류를 이용한 연속호선과 분절호선의 유한요소분석)

  • Lee, Eon-Hwa;Yu, Hyung-Seog;Lee, Kee-Joon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.237-254
    • /
    • 2011
  • Objective: The purpose of this study was to compare the displacement patterns shown by finite element analysis when the maxillary anterior segment was retracted from different orthodontic miniscrew positions and different lengths of lever arms in lingual continuous and segmented arch techniques. Methods: A three dimensional model was produced, the translation of teeth in both models was measured and individual displacement was calculated. Results: When traction was carried out from miniscrews in the palatal slope, lingual tipping of crowns and extrusion of the maxillary anterior segment were found in both continuous and segmented arches as the lever arms were made shorter. With miniscrews in the midpalatal suture area, the displacement patterns were similar to the palatal slope, but bodily movement of the upper incisors was observed in both continuous and segmented arches with the lever arm at 20 mm. When lever arms were longer, there was less extrusion of the incisors and more buccal displacement of the canines. Such displacement was shown less in the continuous arch than the segmented arch. The second premolar showed crown mesial tipping and intrusion, and the molars showed distal tipping in the continuous arch. The posterior segment was displaced three dimensionally in the segmented arch, but the amount of displacement was less than the continuous arch. Conclusions: It is recommended that lever arms of 20 mm in length be used for bodily movement of the anterior segment. Use of continuous or segmented arches affect the displacement patterns and induce differences in the amount of displacement.

Orthodontic Treatment of an Impacted Immature Tooth Using C-tube as a Skeletal Anchorage : Case Reports (C-tube를 골격성 고정원으로 이용한 매복된 미성숙 영구치의 교정적 치료 : 증례 보고)

  • Choi, Sooyeon;Kong, Eunkyung;Chung, Kyurhim;Baek, Kwangwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.157-165
    • /
    • 2014
  • Skeletal anchorage is recommended as an orthodontic treatment for an impacted immature permanent tooth. Among these methods, C-tube is relatively safe because it is fixed to the cortical bone of interdental and the lower part of the root with several short miniscrews, which causes less damage to the root in patients of early permanent dentition. As it can be easily bent, the traction direction can be adjusted to favorable bone density sites. However, patient cooperation is important and traction based on physiological force in order to gain root and dentoalveolar tissue development in immature permanent teeth is required. Periodic follow-ups should be mandatory.

The comparison of torque values in two types of miniscrews placed in rabbits: tapered and cylindrical shapes - Preliminary study (토끼모델을 이용한 미니스크류 형상에 따른 토오크의 평가 - 원통형과 원추형 간의 비교)

  • Kim, Kyung-Ho;Chung, Choo-Ryung;Yoo, Hyun-Mi;Park, Dong-Sung;Jang, In-Sung;Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.280-287
    • /
    • 2011
  • Objective: This study compared the stability of cylindrical miniscrews (Cy, 7 mm in length) with that of tapered miniscrews (Ta, 5 mm in length), using torque values to determine if the healing time before loading affects the stability of the miniscrew and if the insertion torque is associated with the removal torque measured after a few weeks of healing. Methods: Ta and Cy with different thread lengths were placed in the tibias of 12 female New Zealand white rabbits (body weight: 3.0 - 3.5 kg), and the maximum insertion torque values (ITV) were measured. No orthodontic forces were applied so as to allow us to determine the pure effects of the different shapes. After 3 different healing periods (2, 4, and 6 weeks), maximum removal torque values (RTV) were measured immediately before the rabbits were sacrificed. Results: No miniscrews were loosened. There were no significant differences in ITV or RTV between the Ta and Cy nor were there any significant differences in the ITV and RTV between the 3 groups, which had different healing periods. There was a correlation between the ITV and RTV. Conclusions: Shorter Ta showed similar stability as Cy, as determined by torque values. This result strongly suggests that the tapered shape is more advantageous than the cylindrical shape. The RTV did not increase significantly over time. It is recommended that a miniscrew be loaded immediately; waiting a few weeks before loading should be avoided. The correlation between the ITV and RTV suggests that the ITV can be used to estimate a screw's future stability.

Protraction of mandibular molars through a severely atrophic edentulous space in a case of juvenile periodontitis

  • Wu, Jian-chao;Zheng, Yu-ting;Dai, Yi-jun
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.145-154
    • /
    • 2020
  • Moving the mandibular posterior teeth into a severely atrophic edentulous space is a challenge. A carefully designed force-and-moment system that results in bodily protraction of the posterior teeth with balanced bone resorption and apposition is needed in such cases. This report describes the treatment of a 19-year-old woman with missing mandibular first molars due to juvenile periodontitis. Miniscrews were used as absolute anchorage during protraction of the mandibular second and third molars. Bodily mesial movement of the mandibular second and third molars was achieved over a distance of 11 to 17 mm after 39 months of orthodontic treatment.

The skeletal cortical anchorage using titanium microscrew implants (Titanium microscrew implant를 이용한 skeletal cortical anchorage)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.699-706
    • /
    • 1999
  • Anchorage plays an important role in orthodontic treatment. Endosseous implants may be considered adequate firm anchorage. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period before osseointegration occurs. Recently, some clinicians have tried to use titanium miniscrews and microscrews in treatment due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and the ability to place microscrews in any area of alveolar bone. The author treated a case with skeletal cortical anchorage using titanium microscrew implants. During six months of orthodontic force application from skeletal cortical anchorage, the author could get 4 mm bodily retraction and intrusion of upper anterior teeth. The most outstanding result was a 1.5 mm posterior refraction of the upper posterior teeth. The titanium microscrew implants had remained firm and stable throughout treatment. These results indicate that skeletal cortical anchorage might be a very good option.

  • PDF

Miniscrew insertion sites of infrazygomatic crest and mandibular buccal shelf in different vertical craniofacial patterns: A cone-beam computed tomography study

  • Matias, Murilo;Flores-Mir, Carlos;de Almeida, Marcio Rodrigues;da Silva Vieira, Bruno;de Freitas, Karina Maria Salvatore;Nunes, Daniela Calabrese;Ferreira, Marcos Cezar;Ursi, Weber
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.387-396
    • /
    • 2021
  • Objective: To identify optimal areas for the insertion of extra-alveolar miniscrews into the infrazygomatic crest (IZC) and mandibular buccal shelf (MBS), using cone beam computed tomography (CBCT) imaging in patients with different craniofacial patterns. Methods: CBCT reconstructions of untreated individuals were used to evaluate the IZC and MBS areas. The participants were divided into three groups, based on the craniofacial pattern, namely, brachyfacial (n = 15; mean age, 23.3 years), mesofacial (n = 15; mean age, 19.24 years), and dolichofacial (n = 15; mean age, 17.79 years). In the IZC, the evaluated areas were at 11, 13, and 15 mm above the buccal cusp tips of the right and left first molars. In the MBS, the evaluated areas were at the projections of the first molars' distal roots and second molars' mesial and distal roots, at a 4- and 8-mm distance from the cementoenamel junction. Intergroup comparisons were performed with analysis of variance and the Tukey test. Results: There was no statistically significant difference in the IZC bone thickness among the groups. For MBS bone availability, some comparisons revealed no difference; meanwhile, other comparisons revealed increased MBS bone thickness in the brachyfacial (first molars distal roots) and dolichofacial (second molars mesial and distal roots) patterns. Conclusions: There was no significant difference in the IZC bone thickness among the groups. The facial skeletal pattern may affect the availability of ideal bone thickness for the insertion of extra-alveolar miniscrews in the MBS region; however, this variability is unlikely to be clinically meaningful.

A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.) (Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.677-685
    • /
    • 2000
  • Anchorage plays an important role in orthodontic treatment. Because of limited anchorage Potential and acceptance problems of intra- or extraoral anchorage aids, endosseous implants have been suggested and used. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period for osseointegration. Titanium miniscrews and microscrews were introduced as orthodontic anchorage due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and their ability to be placed in any area of the alveolar bone. In this study, a skeletal Class II Patient was treated with sliding mechanics using M.I.A.(micro-implant anchorage). The maxillary micro-implants provide anchorage for retraction of the upper anterior teeth. The mandibular micro-implants induced uprighting and intrusion of the lower molars. The upward and forward movement of the chin followed. This resulted in an increase of the SNB angle, and a decrease of the ANB angle. The micro-implants remained firm and stable throughout treatment. This new approach to the treatment of skeletal Class II malocclusion has the following characteristics . Independent of Patient cooperation. . Shorter treatment time due to the simultaneous retraction of the six anterior teeth . Early change of facial Profile motivating greater cooperation from patients These results indicate that the M.I.A. can be used as anchorage for orthodontic treatment. The use of M.I.A. with sliding mechanics in the treatment of skeletal Class II malocclusion increases the treatment simplicity and efficiency.

  • PDF

Orthodontic intrusion treatment of mandibular anterior teeth in a periodontal patient with hyperdivergent skeletal pattern: 8-year follow-up (장안모를 보이는 치주 질환자에서 하악 전치의 압하를 통한 과개 교합 치료: 8년 경과 관찰)

  • Kwon, Eun-Young;Jung, Kyung-Hwa;Park, Soo-Byung;Kim, Seong-sik;Kim, Yong-il;Choi, Youn-kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.48-60
    • /
    • 2021
  • Patients who have extruded anterior teeth and deep bite with pathologic tooth migration, it is necessary not only periodontal treatment for reduce inflammation, but also orthodontic treatment for intrusion of anterior teeth. However, it is difficult to place the orthodontic brackets due to the deep bite, and there is a problem that the extrusion of the posterior teeth occurs more easily than the intrusion of the anterior teeth biomechanically. In particular, in patients with long face, relative intrusion of the anterior teeth by extrusion of the posterior teeth causes the clockwise rotation of the mandible and makes the facial profile worse. Therefore the biomechanical consideration and appliance design that can block these problems are required from the treatment plan. This is a patient who had a deep overbite with extruded anterior teeth, treated by periodontal treatment and intrusion of mandibular anterior teeth using cute brackes and miniscrews, and resulted in favorable maintenance during 8-year retention.

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

ORTHODONTIC TREATMENT WITH MINISCREWS IN MIXED DENTITION (혼합치열기의 miniscrew를 이용한 교정치료)

  • Lim, Su-Min;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju;Lee, Yong-Hun;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.367-375
    • /
    • 2008
  • Anchorage plays an important role in orthodontic treatment. Skeletal anchorage like the miniscrew is considered a more effective method in anchorage control than conventional anchorage which needs much patient's cooperation. The miniscrew offers many advantages. 1) It is easy to insert and to remove. 2) It can endure the force needed for moving teeth. 3) It can be immediately loaded and 4) Patient cooperation is not needed. 5) It is economic compared to other skeletal anchorage systems. In comparison to adult's bones, children's bones have comparatively poor bone quality and quantity. Therefore, it is hard to obtain primary stability in younger patients. However, if the miniscrew can be retained successfully, it will be effective in many orthodontic treatments. In these cases, we used the miniscrew in correcting of diastema, in aligning dental midline, and in rendering a forced eruption of impacted tooth in mixed dentition patient. We obtained satisfactory results.

  • PDF