• 제목/요약/키워드: Orifice size

검색결과 190건 처리시간 0.025초

알긴산소다를 이용한 멸치어유의 미세캡슐화 (Microencapsulation of Anchovy Oil by Sodium Alginate)

  • 임상빈;좌미경
    • 한국식품영양과학회지
    • /
    • 제28권4호
    • /
    • pp.890-894
    • /
    • 1999
  • Microencapsulation of anchovy oil as a core material in sodium alginate as a wall material was inves tigated. Microencapsulation was accomplished by injecting an oil/water emulsion, consisting of a mixture of liquefied sodium alginate and emulsifier, under high pressure through an orifice submerged in a calcium lactate solution. Microcapsules suspended in a dispersion fluid were observed under a fluorescence mi croscope to verify the presence of the capsules and to note coalescence or degradation of the capsules. Optimum conditions for microencapsulation of anchovy oil were obtained when 1.0% aqueous solution of sodium alginate contained 3% of a 1:1 ratio of ESPR 25(polyglycerine+polylinoleate) and TW 20(sorbitan laurate+ethylene oxide) as an emulsifier in terms of capsule size and size distribution, and emulsion stability. The airless sprayer produced microcapsules with a diameter between 15.9 and 73.9 m with different concentration of a wall material. The optimum mixing ratio of wall material to core material was 90:10(wt/wt). 0.2% calcium lactate was appropriate as a dispersion fluid.

  • PDF

용융 알루미늄내에서 개재물의 크기분포 및 농도측정에 관한 연구 (A Study on the Measurement of the Concentration and the Size Distribution of Inclusions in the Molten Aluminum)

  • 안정;문광호;이광학
    • 한국주조공학회지
    • /
    • 제14권1호
    • /
    • pp.62-74
    • /
    • 1994
  • The concentration and particle size distribution of non-metallic inclusions which suspended in the molten aluminum at $700^{\circ}C$ were measured by using LiMCA apparatus. The result revealed that the number of inclusions increased with increasing the applied current or decreasing the orifice diameter, while decreased with increasing the purity of aluminum. And also, it was found that the number of inclusions increased with increasing the amount of boron added to molten aluminum. This was found to be attributed to the formation of the inclusions of TiB and $V_3B_2$. It was investigated that the average concentration of inclusions in a constant volume of 20ml of molten aluminum was increased in the order of pure molten aluminum, molten aluminum containing 20ppm of boron and molten aluminum used repeatly in the experimental casting in this study.

  • PDF

고속기류에 분사된 액적궤적 및 입경분포에 미치는 주위 기체밀도의 영향 (The effect of gas density on the drop trajectory and drop size distribution in high speed gas stream)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.37-44
    • /
    • 2000
  • High velocity, gas-assisted liquid drop trajectories were investigated under well-controlled experimental conditions at elevated gas densities and room temperature. A monodisperse stream of drops which are generated by a vibrating-orifice drop generator were injected into a transverse high velocity gas stream. The gas density and air jet velocity were adjusted independently to keep the Weber numbers constant. The Weber numbers studied were 72, 148, 270, 532. The range of experimental conditions included studied the three drop breakup regimes previously referred as bag, stretching/thinning and catastrophic breakup regimes. High-magnification photography and conventional spray field photographs were taken to study the microscopic breakup mechanisms and the drop trajectories in high velocity gas flow fields, respectively. The parent drop trajectories were affected by the gas density and the gas jet velocities and do not show similarity with respect to the either Weber or the Reynolds number, as expected.

  • PDF

The Mechanism of Gold Deposition by Thermal Evaporation

  • Mark C. Barnes;Kim, Doh-Y.;Nong M. Hwang
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 2000년도 Proceedings of 2000 International Nano Crystals/Ceramics Forum and International Symposium on Intermaterials
    • /
    • pp.127-142
    • /
    • 2000
  • The charged cluster model states that chemical vapor deposition (CVD) begins with gas phase nucleation of charged clusters followed by cluster deposition on a substrate surface to form a thin film. A two-chambered CVD system, separated by a 1-mm orifice, was used to study gold deposition by thermal evaporation in order to determine if the CCM applies in this case. At a filament temperature of 1523 and 1773 K, the presence of nano-meter sized gold clusters was found to be positive and the cluster size and size distribution increased with increasing temperature. Small clusters were found to be amorphous and they combined with clusters already deposited on a substrate surface to form larger amorphous clusters on the surface. This work revealed that gold thin films deposited on a mica surface are the result of the sticking of 4-10 nm clusters. The topography of these films was similar to those reported previously under similar conditions.

  • PDF

30nm~3000nm 광범위 직경 입자의 공기역학적 집속에 대한 수치해석 (A Numerical Simulation of Aerodynamic Focusing of Nanoparticles in a Wide Range of 30nm~3000nm)

  • 이광승;이동근
    • 한국입자에어로졸학회지
    • /
    • 제7권4호
    • /
    • pp.123-130
    • /
    • 2011
  • Previous designs of conventional aerodynamic lenses have a limitation of narrow range of focusable particle size, e.g. 30 to 300nm or 3 to 30nm. To enlarge the focusable size range to 30-3000nm, it is necessary to avoid a significant loss of particles larger than 300nm inside the lenses. From numerical simulations on size-resolved particle trajectories, we confirmed that the traveling losses of such large particles could be avoided only when the radial position of particles approaching the orifice lens was near the lens axis. Hence, we designed the lens system consisting of a converging-diverging nozzle and 7 orifices to fulfill the requirement. In particular, the orifices were aligned in a way that their diameters were descending and ascending to the downstream. As a result, 30-2800nm particles can be focused to the particle beam of 0.2mm or less in radius with above 85% transmission efficiency. Even $10{\mu}m$ particles can be focused with 74% of transmission efficiency.

다단 임팩터(MOUDI)의 조대 입자 채취 특성 (Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles)

  • 배귀남;지준호;문길주
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

원형 및 타원형 노즐 내부유동과 외부유동의 상관관계 (Correlations of Internal Nozzle Flow in Circular and Elliptical Nozzles with External Flow)

  • 구건우;홍정구;박철우;이충원
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.325-333
    • /
    • 2012
  • 원형 및 타원노즐의 내부유동과 외부유동의 상관관계를 알아보기 위해 실험적 연구가 수행되었다. 분사압력에 따라 유량, 분무각, 액적크기 등의 외부유동에 관해 관찰하였고, 노즐 내부유동의 유속 및 압력분포 등을 수치해석을 통해 정량적인 결과를 도출하였다. 외부유동의 경우, 동일한 압력조건하에서 타원형 노즐의 경우, 원형 노즐에서 나타나지 않는 표면분열의 분무특성을 관찰할 수 있었고, 수치해석을 통해 노즐 내부의 유동을 분석한 결과, 원형의 경우와는 달리 타원형 노즐의 단축에서 내부유동의 재부착이 노즐 벽면에서 발생되었다. 타원노즐 외부유동의 표면분열이 내부유동에 따른 결과라고 판단된다.

Morphological Assessment of Cadaveric Radial, Brachial and Subclavian Arteries : A Neurointerventional Approach

  • Yilmaz, Ali;Ozkul, Ayca;Shin, Dong Seong;Im, Soo-Bin;Yoon, Seok-Mann;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.499-503
    • /
    • 2015
  • Objective : The transradial catheterization (TRC) is becoming widespread, primarily for neurointerventions. Therefore, the evaluation of radial artery puncture in clinical practice and a better understanding of the anatomy are important to improve the safety of neuroendovascular surgery. Methods : Ten formalin-fixed adult Korean cadavers were dissected to expose radial artery (RA), brachial artery (BrA) and subclvian artery (ScA), bilaterally. Vessel lengths and diameters were meaured using a caliper and distance between the specific point of vessels and the anatomical landmarks including the radial styloid process, the medial epicondyle of the humerus, the sternoclavicular joint, and the vertebral artery orifice were also measured. Results : The average length between the radial (RAPS) and the BrA puncture sites (BrAPS) and between the vertebral artery orifice (VAO) and the BrA bifurcation (BrAB) did not differ between sides (p>0.05). The average length between the radial styloid process (RSP) and the RAPS was $13.41{\pm}2.19mm$, and the RSP was $26.85{\pm}2.47mm$ from the median nerve (MN). The mean length between the medial epicondyle (ME) and the BrAPS as $44.23{\pm}5.47mm$, whereas the distance between the ME and the MN was $42.23{\pm}4.77mm$. The average VAO-ScA angle was $70.94{\pm}6.12^{\circ}$, and the length between the ScA junction (SCJ) and the VAO was $60.30{\pm}8.48mm$. Conclusion : This study provides basic anatomical information about the radial artery and the brachial route and can help improving new techniques, selection of size and shape of catheters for TRC. This can help neurointerventionists who adopt a transradial neuroendovascular approach and offers comprehensive and safe care to their patients.

Development of Fishway Assessment Model based on the Fishway Structure, Hydrology and Biological Characteristics in Lotic Ecosystem

  • Choi, Ji-Woong;Park, Chan-Seo;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • 제39권1호
    • /
    • pp.71-80
    • /
    • 2016
  • The main goal of this study is to develop a multi-metric fishway assessment model (Mm-FA) and evaluate the efficiency of fishway. The Mm-FA model has three major fishway components with nine metrics: structural characteristics, hydraulic/hydrologic features, and biological attributes. The model was developed for diagnosing and assessing fishway efficiency and tested to Juksan Weir at the Yeongsan River Watershed. Structural characteristics of fishway included slope of the fishway (M1), ratios of fishway width to stream width (M2), and the proportion of orifice clogging and orifice size (M3). Hydraulic/hydrologic characteristics included depth of fishway entrance head (M4), depth of exit tail (M5), and current velocity of inner fishway (M6). Biological characteristics included fish species ratio of inner fishway to upper-lower weir (M7), fish length distribution (M8), and the proportion of migratory fish species to the total number of species (M9). Overall, the assessment of fishway efficiency showed the total score of the Mm-FA model was 25 in the Juksan Weir, indicating "good condition" by the criteria of the five-level classification system. The Mm-FA model may be used as a key tool for the assessment of fishway efficiency, especially on the 16 weirs constructed for the "Four Rivers Restoration Project" after a partial calibration of Mm-FA model.

ICP-RIE 기술을 이용한 차압형 가스유량센서 제작 (Fabrication of a Pressure Difference Type Gas Flow Sensor using ICP-RIE Technology)

  • 이영태;안강호;권용택
    • 반도체디스플레이기술학회지
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we fabricated pressure difference type gas flow sensor using only dry etching technology by ICP-RIE(inductive coupled plasma reactive ion etching). The sensor's structure consists of a common shear stress type piezoresistive pressure sensor with an orifice fabricated in the middle of the sensor diaphragm. Generally, structure like diaphragm is fabricated by wet etching technology using TMAH, but we fabricated diaphragm by only dry etching using ICP-RIE. To equalize the thickness of diaphragm we applied insulator($SiO_2$) layer of SOI(Si/$SiO_2$/Si-sub) wafer as delay layer of dry etching. Size of fabricated diaphragm is $1000{\times}1000{\times}7\;{\mu}m^3$ and overall chip $3000{\times}3000{\times}7\;{\mu}m^3$. We measured the variation of output voltage toward the change of gas pressure to analyze characteristics of the fabricated sensor. Sensitivity of fabricated sensor was relatively high as about 1.5mV/V kPa at 1kPa full-scale. Nonlinearity was below 0.5%F.S. Over-pressure range of the fabricated sensor is 100kPa or more.

  • PDF