• 제목/요약/키워드: Organic Paint

Search Result 80, Processing Time 0.03 seconds

Test Method Using VOC Analyzer to Measure VOC Emission of Paints for Wood-based Panel (VOC Analyzer를 이용한 목재용 도료의 휘발성유기화합물의 간이측정)

  • Eom, Young Geun;Kim, Ki-Wook;An, Jae-Yun;Kim, Hyun-Joong;Moon, Suck-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.65-72
    • /
    • 2007
  • The VOC (volatile organic compound) analyzer is devised to measure the four main aromatic hydrocarbon gases: toluene, ethylbenzene, xylene and styfene. It is not affected by ambient temperature and humidity. In addition, standby and measuring time of VOC Analyzer is a short as below 30 min and 8 min, respectively. Since the semiconductor gas sensor is supersensitive to gas components, it is not necessary to use a conventional gas concentrator or other complicated equipment. In this study, VOC emission behavior from 4 types paints (lacquer, urethane vanish, water-base paint, enamel paint) for wood-based panel was investigated using VOC Analyzer. After a specimen was spreaded on aluminum foil ($6.32{\times}6.32cm$) in $3{\ell}$ polyester bag, after 24 hours we could measure maximum VOC emission level that is a stabilized VOC value. Xylene of VOCs was high emitted from lacquer, urethane vanish and water-based paint, and TVOC (Toluene + Ethylbenzene + Xylene + Styrene) of lacquer was the highest emission concentration than another.

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.

Measurement of VOC in the Ambient Air of a Small Scale Municipal Landfill Site -A Case Study at the Sampung-dong Landfill in Gyungsan City- (소규모 도시 생활폐기물 매립장 대기 중 VOC의 농도 측정 -경산시 삼풍동 매립장을 대상으로-)

  • 백성옥;김배갑;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.59-68
    • /
    • 2004
  • In this study, we investigated the concentrations of volatile organic compounds (VOC) in the ambient air of a small scale municipal waste landfill site. Seasonal sampling was carried out simultaneously at two sites, i.e. one in the center of the landfill area, and the other at a boundary site. Among 38 target VOC, toluene appeared to be the most dominant compound, followed by benzene. and xylenes. The higher levels of BTX imply that paint -containing materials and/or organic solvents are the most significant sources of the VOC in the landfill environment. Seasonal variations for the samples collected at the landfill site indicated that the VOC concentrations tend to be higher in the spring and fall season and lower in the winter season. In addition, night- time concentrations appeared to be generally higher than day-time. Such daily variation might be due to more stabilized atmosphere during the night-time. Similar patterns were also found in samples collected at a boundary site. This study demonstrated that the municipal landfill, although it is small -scaled, could be an important emission source of atmospheric VOC, particularly in the vicinities of the landfill. Thus, an appropriate control strategy is required to prevent any undesirable secondary pollutions from the environmental sanitary facilities such as landfill.

Development of anti-corrosive coating technique for alloy plated steel sheet using silane based organic-inorganic hybrid materials (Silane계 유무기 하이브리드 적용 합금도금강판 내식성 향상 코팅 기술 개발)

  • Park, Jongwon;Lee, Kyunghwang;Park, Byungkyu;Hong, Shinhyub
    • Corrosion Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.295-303
    • /
    • 2013
  • Silane surface treatments have been developed as an alternative for toxic and carcinogenic chromate-based treatments for years. It is consistently observed that ultra-thin films offer excellent corrosion protection as well as paint adhesion to metals. The silane performance is comparable to, or in some cases better than, that of chromate layers. Based on the tetra-ethylorthosilicate(TEOS) and methlyl trieethoxysilane(MTES), inorganic sol was synthesized and formed hybrid networks with $SiO_2$ nano particle and polypropylene glycol(PPG) on Zn alloyed steel surface. According to SST results, addition of 10nm and 50nm $SiO_2$ nanoparticle in synthesized solution improved anti-corrosion property by its shear stress relaxation effect during curing process. Also, SST results were shown that anti-corrosive property was affected by the amounts of organic compounds.

Analysis of Paint Used for a Helicopter Operated in the Korean War through the History of Paint Application (페인트 도장의 역사를 통해 본 6·25전쟁 운용 헬기의 도료분석)

  • Kang Hyunsam;Jang Hanul;Choi Yangho
    • Conservation Science in Museum
    • /
    • v.29
    • /
    • pp.133-152
    • /
    • 2023
  • This study references preceding studies to examine the history of paint application techniques using various paints in the past, with the aim to contribute to the long-term preservation of large military cultural heritage assets situated outdoors. To this end, the study compared the findings of preceding research with the findings of an analysis conducted on a H-13 helicopter housed at the War Memorial of Korea. Upon collecting and analyzing samples from three grounded WWII aircraft from above-ground by preceding studies, it was confirmed from each sample that the various chemical properties of chrome ensured the effectiveness of the protective coating. The compound was first tested as a corrosion-inhibiting pigment in the early 1940s and proved its excellent moisture-resistant properties over the course of 80 years, despite the deterioration of the paint layer and long-term exposure to the natural environment. For this reason, it has been widely used as a corrosion inhibitor for aluminum alloys in the aviation industry. In other word, the most widely-used material for preventing corrosion was an organic primer containing chromate. In this study, based on the paint analysis of a H-13 helicopter operated in the Korean War, it was shown that the second layer, consisting of the primer, contains chromium oxide (Cr2O3). In addition, it was estimated that red lead tetraoxide (Pb3O4) was used for the vehicle. Analysis results and data from previous studies can help to confirm the continued effectiveness of corrosion prevention function provided by chromate. Meanwhile, the result of infrared spectroscopy analysis confirmed the use of alkyd resin. In the future, comparisons with a more diverse range of artifacts will allow the identification of changes in the manufacturing technology of paints used to protect alloys from corrosion.

Analysis of Paint Pigments on King's Silk Ceremonial Robe with Nine Symbols (은조사 구장복의 채색안료 분석)

  • Yun, Eunyoung;Kang, Hyungtae
    • Conservation Science in Museum
    • /
    • v.15
    • /
    • pp.66-77
    • /
    • 2014
  • A gujangbok is a king's silk ceremonial robe embroidered with nine symbols that represent the essential virtues that a king needs to govern his country. The National Museum of Korea currently own a gujangbok worn by King Gojong in the late Joseon Dynasty. The robe is painted with various colors, including red, yellow, blue, green, and gray. μ-XRF and analysis was conducted on the pigments, and it was found that the red color was made from cinnabar, the yellow color was gold and brass, the blue color was a blue organic pigment and white lead, the green color was a synthetic pigment composed of copper and arsenic, and the gray color pigment was silver. Also, the pigments were compared to those used to make the patterns of a queen's ceremonial robe and a front cloth panel, both made around the same time and also owned by the National Museum of Korea. The comparative analysis revealed clear differences and similarities between the various pigments. The resulting data expect to serve as a useful foundation research for future studying of the pigments used by the Joseon royal court in the late nineteenth century.

Catalytic Oxidation of Toluene over Pd-Activated Alumina Catalysts at Low Temperature (활성알루미나에 담지한 팔라듐 촉매상에서 톨루엔의 저온 연소반응)

  • Lee, Ju-Yeol;Song, Hyung-Jin;Lee, Sang-Bong;Kim, Mi-Hyung;Jo, Young-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.339-347
    • /
    • 2012
  • This study focuses on developing catalysts for the removal of toluene produced from paint booth. Toluene is one of the major VOC in painting, coating process. Pd catalysts have been used in hydrogenation oxidation and low temperature combustion reaction for toluene removal. Pd catalysts, even though it is very precious and expensive. Therefore, the prepared catalysts from minimizing the amount of Pd ratio (0.1~1.0wt%) were measured. As a result, 1.0wt% Pd(R) catalyst under all conditions showed the highest activity. These results may suggest that the catalytic activity is related to Pd dispersion according sintering atmosphere and Pd ratio in the manufacturing process through the analysis of SEM, XRD.

Effects of Several Surfactants in the WBPU/Octadecane as a Phase Change Material (상전이 물질을 함유하는 수분산 PU에서 계면활성제의 효과)

  • Jang, Jae-Hyuk;Lee, Young-Hee;Kim, Han-Do
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.287-288
    • /
    • 2003
  • Polyurethane(PU) materials have been generally used in the automobile, paint, furniture, adhesive, and textile industries. The use of Waterborne PU was motivated form the environmental point of view, i.e. reduction of solvent emissions into the atmosphere(volatile organic compounds, VOC)[1]. Generally speaking, phase change materials (PCM) have the capability of absorbing or releasing thermal energy to reduce or eliminate heat transfer at the temperature range of the particular temperature stabilizing material[2]. (omitted)

  • PDF

A Study on the Flame Propagation Velocity of Methyl Alcohol (메틸알콜의 화염전파속도에 관한 연구)

  • Choi Jae-Wook
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.44-51
    • /
    • 2005
  • The flame propagation velocity and the flame arrival time of methyl alcohol, which is widely used as a material of paint industry and organic synthesis, d mixing solvent, and an analytical reagent, were examined at different temperatures and concentrations. It was found that the smaller the vessel size, the easier and faster the combustion. The maximum combustion velocity was 200 cm/sec in the small vessel at $30^{\circ}C$. The flame arrival time was determined to be longer with larger vessels. and shorter with higher concentrations.

A Study on the Eco-Friendly Durable Pre-Painting for Concrete Structure (콘크리트 구조물의 친환경 내구성 도장에 관한 기초 연구)

  • Jo, Byung Wan;Choi, Ji Sun;Lee, Seong Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • A concrete structure has become bigger and higher because of development of construction technology and a change in construction environment. Also it tends to focus on repairing, reinforcement and exterior in harmony with environment for structure maintenance and performance improvement. The research is about eco friendly durable painting applicable to concrete structure using civil and architecture. it purpose to improve external beauties and durable problems due to flexibility by variation of temperature, adhesion of exterior wall, crack and delamination in existing organic and mineral painting. For those problems, we made a eco friendly pre-paint that is made with preliminary treatment mixture as a highly enriched waterproof agent and adhesive increasing agent in preprocessing mixture. Then we performed an experiment on durability of prevention neutralization of concrete, durability abrasion, hiding power, adhesion, temperature resistance and resistance to chemical attack. The result of an experiment shows that hiding power is over 0.96 in standard test, durability abrasion test got higher value 1mg than water paint 75mg and tensile strength is 6 times higher than standard waterproof specification.