• Title/Summary/Keyword: Organ size

Search Result 263, Processing Time 0.03 seconds

Anti-cancer effect of Sarijang on colorectal cancer cells in a xenograft nude mouse model (대장암 세포가 이식된 동물모델에서 사리장의 항암효과에 대한 연구)

  • Lee, Tae-Hee;Song, Hyun-Kyung;Kim, Dong-Yoon;Lee, Isaac;Seo, Hyeong-Ho;Choi, Ji-Young;Kim, Hong-Geun;Choi, Eun-A;Han, Beom-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.451-456
    • /
    • 2018
  • The current study was conducted to confirm the anti-cancer effect of Sarijang, which is a mixture of extracts from purple bamboo salt, Rhynchosia nulubilis, garlic, and Ulmi cortex. Nude mice were injected with a human-derived colorectal cancer cell (HCT116 cell line) and subsequently administered Sarijang for 4 weeks, following which the body weight, organ weight, and tumor size were measured. To evaluate the anti-cancer mechanism of Sarijang, the levels of p16 and extracellular signal-regulated kinase (ERK), cell cycle regulators in colorectal cancer, were measured. To evaluate the toxicity of Sarijang on liver and kidney, aspartate transaminase, alanine transaminase, blood urea nitrogen, and creatinine were analyzed. Sarijang not only reduced the tumor size by enhancing p16 and suppressing ERK, but also showed no side-effect in the liver and kidneys. Taken together, Sarijang has the potential to inhibit tumor growth without side effects, and may be used as a useful functional food.

Targetability of Surface-modified Albumin Microspheres with Methotrexate (메토트렉세이트가 표면수식된 알부민미립구의 표적성)

  • Hwang, Sung-Joo;Cho, Hang-Bum;Rhee, Gye-Ju;Kim, Chong-Kook
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.2
    • /
    • pp.105-112
    • /
    • 1996
  • The surface of albumin microspheres was modified with methotrexate(MTX) by using 1,3-dicyclohexylcarbodiimide (DCC). Surface-modified albumin microspheres entrapping no MTX (SAMS), free MTX (SAMSF) and MTX-bovine serum albumin(BSA) conjugates(SAMSC) were prepared. The organ-targeting ability of free $[^3H]MTX,\;[^3H]MTX-BSA$ conjugate and the above microspheres was evaluated after i.v. administration of the preparations, equivalent to 150 nCi via the tail vein of mice. The total radioactivity in the lung increased immediately in a few minutes after i.v. injection of the microspheres, and then declined for the period of 3-4 weeks. However, the radioactivity in the liver, spleen and kidney increased slowly during the rapid decrease in radioactivity in the lung. This suggested that the microspheres could be entrapped rapidly in the lung through mechanical filtration because of their large size and slowly redistributed to the liver, spleen and kidney due to either the microspheres being degraded enough for the size to allow passage through the capillary beds of the lung and/or the release of $[^3H]MTX\;or\;[^3H]MTX-BSA$ conjugates from the microspheres. The amount of $60{sim}70%$ of the dose was targeted to the liver after the i.v. injection of SAMS, SAMSF and SAMSC, and the values of $(R_e\;^*\;_{e)liver}$ from the microspheres were $5{\sim}7$ compared to free MTX. This suggested that the liver-targeting ability from surface-modified albumin microspheres could be $5{\sim}7$ times as that of free MTX. The liver-targeted drug was accumulated in the Kupffer cells at the initial stage, thereafter the drug in the Kupffer cell was slowly transferred into the hepatocytes. The value of AUQ for liver from SAMS was higher than that from SAMSF, but much lower than that from SAMSC. This suggest that MTX bound to their surface could be eliminated slower than the entrapped free MTX, and faster than the entrapped MTX-BSA conjugates. This is consistent with the in vitro release rates order in the presence of a proteolytic enzyme. Also, surface-modified MTX was scarcely released in the absence of a proteolytic enzyme. Therefore, the surface-modified MTX nay be released (or eliminated) rapidly from SAMSC at the target site, and thereafter MTX may be released (or eliminated) slowly from the entrapped MTX-BSA conjugates in SAMSC for a long period.

  • PDF

Our Experience with Surgically Treated Epidural Hematomas in Children

  • Jung, Sang-Won;Kim, Dong-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.4
    • /
    • pp.215-218
    • /
    • 2012
  • Objective: Traumatic epidural hematomas (EDHs) in children are a relatively unusual occurrence. The cause and outcome vary depending on period and reg ion of study. The aims of this analysis were to review the cause and outcome of pediatric EDHs nowadays and to discuss outcome-related variables in a large consecutive series of surgically treated EDH in children. Methods: This is a retrospective review of 29 patients with surgically treated EDHs between Jan 2000 and February 2010. Patients' medical records, computed tomographic (Cl) scans, and, if performed, magnetic resonance imaging (MRI) were reviewed to define variables associated with outcome. Variables included in the analysis were age, associated severe intracranial injury, abnormal pupillary response, hematoma thickness, severity of head injury (Glasgow Coma Scale score), parenchymal brain injury, and diffuse axonal injury. Results: The mean (SO) age of the patients was 109 months (0-185 months). Most of the injuries with EDHs occurred in traffic accident (14 cases, 48.2%) and followed by slip down in 6 cases and falls in 6 cases. There were one birth injury and one unknown cause. EDHs in traffic accidents occurred in pedestrians hit by a motor vehicle, 9 cases; motorbike and car accidents, 5 cases and bicycle accidents, 1 case. The locations of hematoma were almost same in both sides (left side in 15 cases). Temporal lobe is the most common site of hematomas (13 cases, 44%). The mean size of the EDHs was 18 mm (range, 5-40 mm). Heterogeneous hematomas in CT scans were 20 cases (67%). Two patients were referred with unilateral or bilateral dilated pupil(s). There was enlargement of EDH in 5 patients (17%). All of them were heterogeneous hematomas in CT scans. Except for 4 patients, all EDHs were associated with skull fracture(s) (87%). There was no case of patient with major organ injury. CT or MRI revealed brain contusion in 5 patients, and diffuse axonal injury in one patient The mortality was zero, and the outcomes were excellent in 26 and good in 2 patients. None of the tested variables were found to have a prognostic relevance. Conclusion: Regardless of the EDH size, the clinical status of the patients, the abnormal pupillary findings, or the cause of injury, the outcome and prognosis of the patients with EDH were excellent.

Auto-Segmentation Algorithm For Liver-Vessel From Abdominal MDCT Image (복부 MDCT 영상으로부터 간혈관 자동 추출 알고리즘)

  • Park, Seong-Me;Lee, You-Jin;Park, Jong-Won
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.430-437
    • /
    • 2010
  • It is essential for living donor liver transplantation that surgeon must understand the hepatic vessel structure to improve the success rate of operation. In this paper, we extract the liver boundary without other surrounding structures such as heart, stomach, and spleen using the contrast enhanced MDCT liver image sequence. After that, we extract the major hepatic veins (left, middle, right hepatic vein) with morphological filter after review the basic structure of hepatic vessel which reside in segmented liver image region. The purpose of this study is provide the overall status of transplantation operation with size estimation of resection part which is dissected along with the middle hepatic vein. The method of liver extraction is as follows: firstly, we get rid of background and muscle layer with gray level distribution ratio from sampling process. secondly, the coincident images match with unit mesh image are unified with resulted image using the corse coordinate of liver and body. thirdly, we extract the final liver image after expanding and region filling. Using the segmented liver images, we extract the hepatic vessels with morphological filter and reversed the major hepatic vessels only with a results of ascending order of vessel size. The 3D reconstructed views of hepatic vessel are generated after applying the interpolation to provide the smooth view. These 3D view are used to estimate the dissection line after identify the middle hepatic vein. Finally, the volume of resection region is calculated and we can identify the possibility of successful transplantation operation.

Ultrastructural Character on the Cuticular Surface of Thelazia callipaeda (Thelazia callipaeda 표피각질층의 미세구조적 특징)

  • Kim, Soo-Jin;Joo, Kyoung-Hwan;Chung, Myung-Sook
    • Applied Microscopy
    • /
    • v.32 no.1
    • /
    • pp.45-55
    • /
    • 2002
  • The worm of Thelazia callipaeda Railliet et Henry, 1910 (The oriental eye worm) was frequently observed in the eyes of animal and human in Korea. But it did not clearly describe about the ultrastructural character on the sensory papillae and cuticular striation of the worm. This study was performed to investigate the ultrastructure and character on the cuticular surface of the worm that was extracted from the eyes of two patients in Korea University Medical Center, using the scanning electron microscopy. According to the mouth, 1/4, 1/2, 3/4 and tail portion of the worm, the size of cuticular striation on each portion was measured. The size of cuticular striation on the worm surface was $1.8{\mu}m$ in the mouth and tail portion, $4.0{\sim}4.5{\mu}m$ in the middle portion of the worm. On the scanning electron microscopy, the female worms were developed phasmids in the tail end and male worms were developed sensory papillae and external sexual organ on the tail end. The sensory papillae on the tail end were composed anterior ventral postcloacal papillae, middle ventral postcloacal papillae, subventral postcloacal papillae, and lateral papillae. According to the result in this study, it is considered that the character of the cuticular striation and the sensory papillae were able to accept as classifying key for the identification of species.

A Simulation study on the Cardiac Current Density distribution during the Defibrillation Shock (제세동 쇼크에 의한 심장 전류밀도 분포에 관한 시뮬레이션 연구)

  • Lee, J.;Park, K. L.;Lee, K. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.403-409
    • /
    • 2000
  • This paper is about to simulate the defibrillation situations using 3D FE(finite element) thorax model and describes the effects of three clinical electrodes' positions and size and organ's resistivity used in simulation on the characteristics of current density distribution over myocardium. The model was constructed with a eillipsoidal cylinder for the thorax and the 2D Visible Human images for remains. And, the distributions of current density were computed by a commercial program ANSYS 5.4. The electrical shock of the AP(anterior-posterior ) electrode provided more current flows with heart than the others and that of the LL(lateral-lateral) electrode showed the most uniform current density distribution. However, the electrode size had little effect on the current density distribution. In the evaluation of model's sensitivity to tissue resistivity variation, the variation of the myocardium's resistivity most affected the minimum, average and maximum current densities.

  • PDF

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

Traumatic Injuries of the Diaphragm (외상성 횡격막 손상)

  • 김덕실;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.433-439
    • /
    • 1996
  • From January 1980 to July 1995, 32 patients with blunt diaphragmatic trauma and 12 wish penetrating diaphragmatic trauma were treated at Kyungpook University Hospital. The mean age of patients with blunt trauma was 37.6 years, and with penetrating trauma 29.2 years. The mean age was older in patients with blunt trauma by 8.4 years (p< 0.05). When simple chest X-ray diagnosis was performed, 24cases (75%) of the diaphragmatic injuries were found in blunt trauma and 4 case(33%) in penetrating trauma. When opei.ations were done due to injuries of thoracic or abdominal organ, 7 diaphragmatic injuries (58%) were found in penetrating trauma. Herniation occurred in 24 patients (75%) in blunt trauma and 5 patients (42%) in penetrating truma. The size of injured diaphragms in 29 cases in which hernia was discovered was 10.9 $\pm$ 4.3cm. On the other hand, the size in 15 cases in which hernia did not occur was 3.5 $\pm$ 2.9cm. There was a remarkable difference in their size depending on the presence or absence of hernia (p< 0.051. That is, a close relation between the sire of injured diaphragms and hernia was shown. All diaphragmatic injuries were repaired primarily. In blunt trauma approach of repair were as follows : 20 (63%) thoracic, 9 abdominal, 2 thoracoabdominal, and 1 thoracic and in penetrating trauma 6 (50%) abdominal, 4 thoracic, and 2 thoracic and abdominal. The complication rate was 19% in blunt trauma and 25% in penetrating trauma. Two patients with blunt trauma died with a mortality rate of 6.3% . All patients with penetrating trauma recovered. This study suggests that diaphragmatic injury should be suspected in all patients w th blunt as well as penetrating injury of the chest and abdomen. The size of injured diaphragms was larger in blunt trauma than in penetrating trauma. For herniation, it appeared to be more common in blunt trauma. The morbidity and mortality were related primary to the severity of associated injuries.

  • PDF

Histopathological Changes in Cold-Stored Dog Lungs to the Preservation Solutions (냉한에서 보관된 황견의 폐에서 장기 보존액에 따른 조직 세포의 변화)

  • 김해균;이두연
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.816-821
    • /
    • 1996
  • Lung transplantation is the established treatment for the end stage lung disedse find preservation of the organ is a major obstacle In performing lung transplantation. For solving this problem, we evaluated the histopathologic changes for various preservation solutions. Male mongrel dogs of similar size and weight (15∼20 kg) were used. The dog lungs were flushed with 4fl normal saline(group 1 'n:5): Modified Euro-Collins solution(group 2 n:5) and University of Wisconsin solution (group 3 : n=6), 60m11kg through a catheter placed in the main pulmonary artery aft r flushing of PGE 1 (20ng1kg). The lungs were preserved for 60 hours and measured dry and wet weights. Histologic specimens were taken every 6 hours and %toed for light microscopic evaluation. The edema ratio of the lungs peaked in 12 hours although there was no difference between the groups. Histologically, alveolar septal changes developed in one case (20%) after 1 hour preservation with normal saline. In case of the University of Wisconsin solution, the alveolar septal distortions and swellings were seen in 1 cases (20%) after 6 hours preservation compared with 3 cases (60%) after 6 hours preservation with Modified Euro-Collins solution. Changes of the pneumocytes were observed after 24 hours preser- vation in group 1, after 48 hours preservation in group 2 and after 60 hours preservation in group 3. We conclude that University of Wisconsin solution might have a superior preservation effect compare to normal saline and Modified Euro-Collins solutions.

  • PDF

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF