플라이애쉬 함유량이 콘크리트의 굳기전 성질 및 역학적 특성에 미치는 영향 (Influence of Fly Ash Content with Respect to the Fresh and Mechanical Properties in Concrete)

  • 이진용;최수홍;강석화;이광명
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.25-33
    • /
    • 1999
  • The role of fly ash in concrete become impotant with finding the charateristics of fly ash in which it is used as cement replacement material. An experimental study is carried out to investigate the characteristics of concrete containing fly ash. The loss of slump and air content of fly ash concrete tested up to 120 minutes are lower than those of ordinary concrete, but the setting time and bleeding are increased with increasing fly ash content. The compressive and tensile strength of fly ash concrete are slightly lower than those of ordinary concrete between 7 and 28 days, however, the long-term (at 180 days) compressive strength of fly ash concrete is significantly higher. In addition, fly ash reduces the heat of hydration and peak of temperature rise in concrete.

방청제에 의한 콘크리트 내의 철근 방식법에 관한 실험적 연구 (An Experimental Study on the Corrosion Protection Method of Reinforcing Steel in Concrete by Using Corrosion Inhibitor)

  • 배수호;정영수;권영우;김년산;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.710-713
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. The most economical method of them will be the corrosion protection method using corrosion inhibitor as concrete admixture. Therefore, the purpose of this research is to investigate the performance of corrosion protection of ordinary strength and high strength concrete using corrosion inhibitor, respectively. For this purpose, after manufacturing ordinary strength and high strength concrete with and without corrosion inhibitor, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles (140 day) of wetting ($65^{\circ}C$, 90% R.H.) and drying period ($15^{\circ}C$, 65% R.H.). As a result, th high strength concrete using corrosion inhibitor showed an excellent performance of corrosion protection.

  • PDF

수중불분리성 콘크리트의 해수침식에 대한저항성 평가 (Assessment on the Seawater Attack Resistance of Antiwashout Underwater Concrete)

  • 문한영;김성수;안태송;이승태;김종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.683-688
    • /
    • 2001
  • In case of constructing the concrete structures under seawater environment, the concrete suffers from deterioration due to penetration of various ions such as chloride, sulfate and magnesium in seawater. Tn the present study, Immersion tests with artificial seawater were carried out to investigate the resistance to seawater attack of antiwashout underwater concrete. From the results of compressive strength, it was found that blended cement concrete due to mineral admixtures such as fly ash(FA) and ground granulated blast-furnace slag(SGC), were superior to ordinary portland cement concrete with respect to the resistance to seawater attack. Moreover, XRD analysis indicated that the formed reactants of ordinary portland cement paste by sulfate and magnesium ions led to the deterioration of concrete. As expected, however, the blended cements with FA or SGC have a good resistance to seawater attack. This paper would discuss the mechanism of seawater deterioration and benefical effects of antiwashout underwater concretes with mineral admixtures.

  • PDF

농수로 구조물의 내구성 저하 요인 (Deterioration Factors of Agricultural Hydraulic Structures)

  • 조성현;김진만;김기동;고만기;김종옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.647-650
    • /
    • 1999
  • Deterioration of agricultural hydraulic structures(AHS), which are under harsh environmental conditions, is more sever than other ordinary structures. To investigate the deterioration factors of AHS, various physical and chemical analyses are performed. The porosity of AHS increases more rapidly than ordinary structures because they are subject to frequent water permeation and water-soluble materials are easily emitted to surface area. Thus, AHS are tend to be damaged by freezing and thawing more easily due to the increase of water containment inside concrete.

  • PDF

합성보의 최적설계 프로그램 개발 (Development of Optimization Design Programs for Composite Beams)

  • 구민세;김긍환;유영찬
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.91-94
    • /
    • 1990
  • The object of this study is to develop computer programs with which ordinary engineers can analyse or design steel-concrete composite teams using optimization technique. Various design ana construction techniques which could maximize load carrying capacities and control concrete tension cracks effectively are studied and included in the programs. Analysis results show that proposed construction techniques can reduce steel weight by about 10%∼20% compared with ordinary composite beam. Concrete tensile stresses can also be controlled affectively by the suggested techniques.

  • PDF

적산온도에 의한 고유동콘크리트의 압축강도 예측 (Prediction of the Compressive Strength of High Flowing Concrete by Maturity)

  • 길배수;한장현;김규용;권영진;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.281-286
    • /
    • 1998
  • The aim of this study is to compare the development of compressive strength of high-Flowing concrete with maturity and to investigate the applicability of strength prediction models of concrete. An experiment was attempted on the high-flowing concrete mixes using Ordinary portland cement, High belite cement, Blast furance slage cement and replaced Fly-ash of 30% by weight of Ordinary portland cement, the water-binder ratios of mixes being 0.35 and the curing temperatures being 30, 20, 10, 5$^{\circ}C$. Test results of mixes are statistically analyzed to infer the correlation coefficient between the maturity and the compressive strength of high-flowing concrete.

  • PDF

촉진시험에 의한 콘크리트중의 황산이온 확산계수 추정 (Estimation on the Sulfate Ion Diffusivity in Concrete by Accelerated Test)

  • 문한영;김성수;김홍삼;이승태;최두선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.425-428
    • /
    • 2000
  • When concrete structures are exposed to sulfate or marin environments, sulfate ions penetrated into concrete make it deteriorate. An accelerated test under potential difference method was performed to evaluate not only the sulfate ion diffusivity in ordinary portland cement and ground granulated blast-furnace slag cement concretes but the effect of slag replacement and water-cement ratio on the sulfate ions diffusivity. As the result of this study, we assumed the sulfate ion diffusivity was significantly related with total passed charge and initial current in concrete. Moreover sulfate ions penetration resistance of ordinary portland cement concrete was superior to that of ground granulated blast-furnace slag cement concrete.

  • PDF

고로슬래그 미분말을 사용한 해양콘크리트 구조물의 염분침투해석 (Finite Element Analysis of the Effect of Chloride Ion on the Coastal Concrete Structure with Ground Granulated Blast Furnace Slag)

  • 여경윤;김은겸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.945-950
    • /
    • 2000
  • Coastal concrete structure is harmed by physical and chemical action of sea water, impact load, meteorological effect and etc. especially, premature reinforcement corrosion in concrete exposed to sea water has an important problem. In this study, the behavior of chloride ions penetrated through the coastal concrete structure with ordinary portland cement or ground granulated blast furnace slag(GGBFS) was modeled. The physicochemical processes including the diffusion of chloride and the chemical reaction of chloride ion with calcium silicate hydrate and the other constituents of hardened cement paste such as$C_3A$ and $C_4AF$were analyzed by using the Finite Element Method. From analysis result, the corrosion of concrete structure with GGBFS begins 1.69~1.76 times later than that of concrete structure with ordinary portland cement.

Adhesion Strength and Other Mechanical Properties of SBR Modified Concrete

  • Chmielewska, Bogumila
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.3-8
    • /
    • 2008
  • Polymer-cement composites are known repair materials. The aim of this work is to investigate the influence of various amount of dispersion of carboxylated styrene-butadience copolymer on the selected mechanical properties of polymer-cement concrete (PCC) and on its adhesion to ordinary concrete. The compressive, flexural and tensile strengths as well as frost resistance and fracture resistance of the composites are tested. Adhesion strength of PCC to ordinary concrete, as one of most important performance of good repair material is evaluated and analyzed using three test methods. The results obtained in standard pull-off test are compared with the two other tests. The first one, which is an adaptation of WST (wedge splitting test) characterizes crack propagation in the plane of bond created during repair. In the second test the resistance to shear is a measure of adhesion strength.

라텍스 개질 콘크리트의 건조수축특성 (Drying Shrinkage Properties of Latex Modified Concrete)

  • 윤경구;홍창우;이주형
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.301-306
    • /
    • 2001
  • Drying shrinkage cracking which may be caused by the relatively large specific surface is a matter of grave concern for latex modified concrete(LMC) overlay and rapid-setting cement latex modified concrete(RSLMC) overlay. Therefore, the purpose of this dissertation was to study the drying shrinkage properties of LMC and RSLMC with the main experimental variables such as cement types(ordinary portland cement, rapid setting cement), latex contents(0, 5, 10, 15, 20%), W-C ratios, and curing days at a same controlled environment of 60% of relative humidity and $20^{\circ}C$ of temperature. Test results revealed that the drying shrinkage of latex modified concrete(LMC), rapid-setting cement latex modified concrete(RSLMC) was considerably lower than that of ordinary portland cement concrete(OPC), rapid-setting cement concrete(RSC), respectively. This may be attributed to the interlocking of hydrated cement and aggregates by a film of latex particles, water retention due to hydrophobic and colloidal properties of the latexes, resulting in reduced water evaporation.