• 제목/요약/키워드: Order release

검색결과 1,144건 처리시간 0.027초

P RELEASE AND UPTAKE ACCORDING TO INFLUENT ORGANIC LOADING IN BNR PROCESS

  • Kim, Kwang-Soo;Ahn, Chang-Hoon;Park, Jae-Kwang
    • Environmental Engineering Research
    • /
    • 제10권6호
    • /
    • pp.265-268
    • /
    • 2005
  • A batch-type study was conducted to investigate the phosphorus release and uptake under anaerobic and aerobic conditions according to organic loading changes. As organic loading increased, anaerobic P release increased but aerobic P uptake decreased. Where organic carbon contents remain high in aerobic conditions, PHB consumption within the microbial cells diminished, therefore it was found that in order to enhance P uptake rate, it should reach the endogenous growth stage where the entire organic loading was consumed.

Batch Variation and Pharmacokinetics of Oral Sustained Release Melatonin-loaded Sugar Spheres in Human Subjects

  • Lee, Beom-Jin;Ryu, Seung-Goo;Choi, Han-Gon;Kim, Chong-Kook;Parrott, Keith-A.;Ayres, James-W.;Sack, Robert-L.
    • Archives of Pharmacal Research
    • /
    • 제20권6호
    • /
    • pp.555-559
    • /
    • 1997
  • The three different batches of an oral sustained release melatonin (MT) delivery system were prepared by aqueous-based fluid-bed coating of the sugar spheres for the evaluation of in vitro release characteristics and plasma concentration profiles in human subjects. The MT contents in 20% coated sugar spheres of three batches (B1, B2 and B3) were $3.3{\pm}0.08$, $2.4{\pm}0.1$ and $2.5{\pm}0.13$ mg per gram of coated sugar spheres, respectively. The release profiles of three different batches had a very similar fashion. However, the release profiles of three different batches had a very similar fashion. However, the release half-lives $(T_{50%})$ of MT from B1, B2 and B3 was $3.70{\pm}0.2$, $5.2{\pm}0.2$ and $4.9{\pm}0.07h$, respectively. Plasma concentration profiles of sustained release 0.2mg melatonin-loaded sugar spheres containing 10% immediate release melatonin in gelatin capsules (B1 and B2) were then evaluated in human subjects. The in vivo plasma concentration profies of the two batches (B1 and B2) were very similar each other and located between the physiological endogenous ranges. The time to reach the peak concentration $(T_max)$ was more advanced in case of B1 when compared to B2. However, there was no statistically significant difference in the maximum concentration $(C_max)$ and the area under the curve (AUC) between B1 and B2. The AUC of melatonin-loaded sugar spheres containing 10% and 20% immediate release MT in human subjects had a good linearity between dose and AUC, regardless of the fraction of immediate release MT, indicating the first order elimination process of MT within these doses. The current oral sustained release MT delivery system may be utilized to treat circadian rhythm disorders if it is proven to be more clinically useful when compared to immediate release MT.

  • PDF

Complexity Analysis of the Viking Labeled Release Experiments

  • Bianciardi, Giorgio;Miller, Joseph D.;Straat, Patricia Ann;Levin, Gilbert V.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권1호
    • /
    • pp.14-26
    • /
    • 2012
  • The only extraterrestrial life detection experiments ever conducted were the three which were components of the 1976 Viking Mission to Mars. Of these, only the Labeled Release experiment obtained a clearly positive response. In this experiment $^{14}C$ radiolabeled nutrient was added to the Mars soil samples. Active soils exhibited rapid, substantial gas release. The gas was probably $CO_2$ and, possibly, other radiocarbon-containing gases. We have applied complexity analysis to the Viking LR data. Measures of mathematical complexity permit deep analysis of data structure along continua including signal vs. noise, entropy vs.negentropy, periodicity vs. aperiodicity, order vs. disorder etc. We have employed seven complexity variables, all derived from LR data, to show that Viking LR active responses can be distinguished from controls via cluster analysis and other multivariate techniques. Furthermore, Martian LR active response data cluster with known biological time series while the control data cluster with purely physical measures. We conclude that the complexity pattern seen in active experiments strongly suggests biology while the different pattern in the control responses is more likely to be non-biological. Control responses that exhibit relatively low initial order rapidly devolve into near-random noise, while the active experiments exhibit higher initial order which decays only slowly. This suggests a robust biological response. These analyses support the interpretation that the Viking LR experiment did detect extant microbial life on Mars.

플라즈마 표면처리 방법을 이용한 웨이퍼레벨 몰딩 공정용 기판의 최적 이형조건 도출 (Study on the Optimal Release Condition of Wafer Level Molding Process using Plasma Surface Treatment Method)

  • 연시모;박진호;이낙규;박석희;이혜진
    • 융복합기술연구소 논문집
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 2015
  • In wafer level molding progress, the thermal releasing failure phenomenon is shown up as the important problem. This phenomenon can cause the problem including the warpage, crack of the molded wafer. The thermal releasing failure is due to the insufficiency of adhesion strength degradation of the molding tape. To solve this problem, we studied experimental method increasing the release property of the molding tape through the plasma surface treatment on the wafer substrate. In this research, the vacuum plasma treatment system is used for release property improvement of the molding tape and controls the operating condition of the hydrophilic($O_2$, 100kW, 10min) and hydrophobic($C_2F_6$, 200kW, 10min). In order to perform the peeling test for measuring the releasing force precisely, we remodel the micro scale material property evaluation system developed by Korea institute of industrial technology. In case of hydrophilic surface treatment on the wafer substrate, we can figure out the releasing property of molding tape increase. In order to grasp the effect that it reaches to the release property increase when repeating the hydrophilic treatment, we make an experiment with twice treatment and get the result to increase about 12%. We find out the hydrophilic surface treatment method using plasma can improve releasing property of molding tape in the wafer level molding process.

치과용 아말감 내부의 수은 유출과 기포의 발생에 관한 연구 (A Study on occurrence of porosity and leakage of mercury in dental amalgam's inside)

  • 김주원
    • 한국치위생학회지
    • /
    • 제10권3호
    • /
    • pp.531-540
    • /
    • 2010
  • Objectives : In this study, following the cavity restorations with low copper conventional alloy, high copper admixed one and high copper unicompositional one, which are used the most frequently in a clinical setting at the present, to experiment the time-dependent changes of strength, bubbles were examined. Besides, to examine the detrimental effects of mercury contained in dental amalgam, the amount of mercury release was evaluated. Methods : As dental amalgams which were used herein, [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy] were selected for a low-copper conventional amalgam, a high-copper admixed one and a high-copper unicompositional one in the corresponding order. The formation of bubbles and the weight ratio of mercury release were evaluated using a field emission scanning electron microscope (FE-SEM). Thus, the following results were obtained: Results : 1. The time-dependent amount of mercury release reached a statistical significance in three types of alloys, which was shown in such a descending order as [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy]. 2. A low-copper conventional type, BESTALOY is a cutting type and it was found to have an increased formation of fine bubbles. In the remaining two types, [Hi-Aristaloy 21] (a high-copper admixed alloy) and [Sybraloy] (a high-copper unicompositional alloy), the time-dependent changes in the formation of bubbles was negligible. Conclusions : Accordingly, this type of mercury release from amalgam alloy denotes the difference in the weight ratio of total constituents between after 24 hours and after two weeks. But further studies are warranted to examine the amount of mercury release which is detrimental to human bodies. Besides, a low-copper conventional alloy is a cutting type and it was characterized by the abundant formation of bubbles in a time-dependent manner. This implies that the strength of amalgam is impaired, which should be considered in selecting the appropriate amalgam alloy in a clinical setting.

Rosin Microparticles as Drug Carriers: Influence of Various Solvents on the Formation of Particles and Sustained-release of Indomethacin

  • Lee Chang Moon;Lim Seung;Kim Gwang Yun;Kim Do Man;Kim Dong Woon;Lee Hyun Chul;Lee Ki Young
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.476-481
    • /
    • 2004
  • The aim of this study was to formulate a sustained release system for indomethacin (IND) with rosin gum obtained from a pine tree. Rosin microparticles were prepared by a disper­sion and dialysis method without the addition of surfactant. In order to investigate the influence of solvents on the formation of colloidal microparitcles, various solvents like ethanol, DMF, DMAc, and acetone were used. The rosin microparticles containing IND were characterized by X­ray differactometry (XRD) and differential scanning calorimetry (DSC). The morphologies of rosin microparticles observed by scanning electron microscopy (SEM) were spherical. The solvents used to dissolve rosin significantly affected the drug content and drug release rate of IND. The release behaviors of IND from the rosin microparticles were dependent on the drug content and size of the particles. Rosin micorparticles with a higher drug content and of a larger particle size had a slower drug release rate. Also, the IND release rate from the rosin microparticles could be regulated by the rosin content in the microparticles. From these results, rosin microparticles have the potential of being used as a sustained release system of IND.

Poly(DL-lactide)로 피막된 고분자 매트릭스로부터 약물 방출 조절 I. pH 1.2 염산 용액에서 피막물질이 약물방출에 미치는 영향 (Control of Drug Release from Polymeric Matrices Coated with Poly(DL-lactide) I. Effect of Coasting Substance on the Drug Release in pH 1.2 Hydrochloride Solution)

  • 나재운;박영훈
    • KSBB Journal
    • /
    • 제14권3호
    • /
    • pp.297-302
    • /
    • 1999
  • Poly(DL-lactide)로 피막된 고분자 매트릭스를 약물전달시스템에 이용하기 위해 키토산, 키토산 염산염 및 술폰화 키토산으로 제조되었다. 모델 약물로 프레드니솔론을 사용하는 본 약물방출에 관한 연구는 pH 1.2 염산 용액에서 실험을 하였다. 약물 방출 속도는 고분자 매트릭스의 함유량이 증가할 수록 감소하였다. 피막된 고분자 매트릭스의 종류에 따라 지연된 약물의 방출시간은 키토산의 경우가 가장 길었으며, 술폰화 키토산, 키토산 염산염의 순서였다. DL-PLA로 피막된 고분자 매트릭스가 피막되지 않는 고분자 매트릭스 보다 약물 방출시간이 2배 정도의 지연되었을 뿐만 아니라 초기에 약물 과잉방출 현상도 작아 피막된 경우가 방출 조절형 제재로서 더 바람직한 결과를 보였다. 따라서 DL-PLA로 피막된 고분자 매트릭스는 장시간의 약물 방출을 위한 약물전달체로써의 응용이 기대된다.

  • PDF

염산 프로프라놀롤-고체 분산계-폴리비닐알코올 하이드로겔 중공좌제로부터의 약물방출 (Controlled Release of Propranolol Hydrochloride(PPH) from PPH-Solid Dispersion System-Polyvinyl Alcohol Hydrogel Hollow Type Suppository)

  • 정진훈;이정연;구영순
    • Journal of Pharmaceutical Investigation
    • /
    • 제26권4호
    • /
    • pp.299-308
    • /
    • 1996
  • In order to develop the controlled release of a drug from the suppsitories, in vitro drug release and in vivo absorption in rabbits were investigated. Various suppository forms with hollow cavities, into which drugs in the form of fine powder or solid dispersion system(SDS) could be placed, were utilized. The polyvinyl alcohol(PVA) hydrogel as a base, and propranolol HCl(PPH) as a model drug were employed. In vitro drug dissolution studies showed that the dissolved amounts(%) of PPH from PPH-methylcellulose(MC)-SDS and PPH-ethylcellulose(EC)-SDS reached 100% and 63% in 4.5-hours, respectively. In the relative strength test for PVA hydrogel, PVA hydrogel became harder and more rigid when the number of freezing-thawing cycles and the ratio of PVA 2000 were increased. In vitro drug release profile revealed that the release rate(%) of PPH from PPH-EC-SDS and PPH-MC-SDS hollow type suppositories were sustained. The release amount(%) of PPH from PPH-EC-SDS hollow type suppositories was not affected by storage time, but since the use of hydrophilic MC made PPH diffuse into the hydrogel after it absorbed the water of base, the various release patterns were appeared as the storage time went by. In vivo absorption experiments with rabbits showed that PPH-EC-SDS(PPH : EC=1:3) hollow type suppository delayed the absorption of PPH, significantly. The $C_{max}$, $AUC_{0{\rightarrow}8}$ and MRT of PPH powder hollow type suppository were $196.37{\pm}5.63\;ng/ml$, 1105.26 ng/ml/min and 8.66 min, respectively. The $C_{max}$, $AUC_{0{\rightarrow}8}$ and MRT of PPH-EC-SDS(PPH : EC=1:3) were $91.30{\pm]14.14\;ng/ml$, 554.69 ng/ml/min, 235.99 min, respectively.

  • PDF

해양퇴적물에서 중금속 용출 차단 및 퇴적물 산소 요구량 감소를 위한 석회석, 제올라이트 및 폐콘크리트의 피복 소재로서 적용 (Application of Limestone, Zeolite, and Crushed Concrete as Capping Material for Interrupting Heavy Metal Release from Marine Sediments and Reducing Sediment Oxygen Demand)

  • 강구;박성직
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.31-38
    • /
    • 2015
  • This study aims to assess the effectiveness of limestone, zeolite, and crushed concrete as capping material to block the release of heavy metals (As, Cu, Cr, Ni, and Pb) and reduce the sediment oxygen demand. The efficiency of limestone, zeolite, and crushed concrete was evaluated in a reactor in which a 1-cm thick layer of capping materials was placed on the sediments collected from Inchon north harbor. Dissolved oxygen concentration and heavy metal concentration in seawater above the uncapped sediments and capping material were monitored for 17 days. The sediment oxygen demand was in the following increasing order: crushed concrete ($288.37mg/m^2{\cdot}d$) < zeolite ($428.96mg/m^2{\cdot}d$) < limestone ($904.53mg/m^2{\cdot}d$) < uncapped ($981.34mg/m^2{\cdot}d$). The capping materials could reduce the sediment oxygen demand by blocking the release of biochemical matters consuming dissolved oxygen in seawater. It was also shown that zeolite and crushed concrete could effectively block the release of Cu, Ni, and Pb but those were not effective for the interruption of As and Cr release from marine contaminated sediments.

정적연소기에서 점화장치가 열발생률과 잘량연소율에 미치는 영향에 관한 연구 (A Study on the Effects of Ignition Systems on the Heat Release Rate and Mass Fraction Burnt at a Constant Volume Combustion Chamber)

  • 송정훈;이기형;선우명호
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1486-1496
    • /
    • 2000
  • The initial flame kernel development and flame propagation in a constant volume combustion chamber is analyzed by the heat release rate and the mass fraction burnt. The combustion pressure is measured with a piezoelectric type pressure sensor. In order to evaluate the effects of ignition system and ignition energy on the flame propagation, four different ignition systems are designed and tested, and the ignition energy is varied by the dwell time. Several different spark plugs are also tested and examined to analysis the effects of electrodes on flame kernel development. The results show that the when the dwell time is increased, and when the spark plug gap is extended, heat release rate and the mass burnt fraction are increased. The materials and shapes of electrodes affect the flame development, because they change the energy transfer efficiency from electrical energy to chemical energy. The diameter of electrodes influences not only the heat release rate but also the mass burnt fraction as well.