• Title/Summary/Keyword: Order of Magnitude

Search Result 1,601, Processing Time 0.032 seconds

Damage Caused by Tsunami and Warning System (지진해일의 피해와 예보체계)

  • Kang, Young-Seung
    • Journal of the Korean Professional Engineers Association
    • /
    • v.38 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • A Tsunami was generated by the magnitude 9.0 earthquake which occurred near Indonesia. An energetic Tsunami will display vertical water displacement of the order of ten meters and lateral scales of the order of tens of kilometers. The Tsunami destroyed many coastal villages in Asia. So, there are many victims in southeastern part Asia by Tsunami. Therefore, the construction of Tsunami prediction and warning system is needed for minimize the damage by seismic sea waves.

  • PDF

Fatigue Test Method for RC Beam Under Random Loading (랜덤하중에 의한 RC보의 피로시험법에 관한 연구)

  • 권혁문;사림신장;정상정일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.179-183
    • /
    • 1993
  • Loads acting on concrete structures are completely random in nature with respect to frequency, magnitude and order of loading, and are essentially distinct from the loads in two-stage and variable load fatigue test. Thus, this study proposes the fatigue test method generating random loads based on the analyzed result.

  • PDF

The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어)

  • Yang, Lee-U;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

Seismic Behavior of Inverted T-type Wall under Earthquake Part II : Effect of Input Earthquake Motion (역T형 옹벽의 지진시 거동특성 Part II : 입력 지진파의 영향)

  • Lee, Jin-sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.9-19
    • /
    • 2016
  • Permanent deformation plays a key role in performance based earthquake resistant design. In order to estimate permanent deformation after earthquake, it is essential to secure reliable response history analysis(RHA) as well as earthquake scenario. This study focuses on permanent deformation of an inverted T-type wall under earthquake. The study is composed of two separate parts. The first one is on the verification of RHA and the second one is on an effect of input earthquake motion. The former is discussed in companion paper and the latter in this paper. In order to investigate the effect of an input earthquake motion on the permanent deformation, three bins of spectral matched real earthquake records with different magnitude, regions, epicentral distance are constructed. Parametric study was performed using the verified RHA through the companion paper for each earthquake records in the bins. The most influential parameter affecting permanent displacement is magnitude. The other parameters describing earthquake motion are not significant enough to increase permanent displacement of the inverted T-type wall except for energy related parameters(AI, CI, SEI).

Numerical Analysis for the Secondary Flow and Heat Transfer of a Reiner-Rivlin Fluid in a Rectangular Duct (직사각형 덕트에서 Reiner-Rivlin 유체의 이차유동 및 열전달에 관한 수치해석)

  • Jung, Suk Ho;Sohn, Chang Hyun;Shin, Sehyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1208-1216
    • /
    • 1998
  • The present numerical study investigates the effect of a secondary flow on the heat transfer in order to delineate the mechanism of laminar heat transfer enhancement of a viscoelastic fluid in rectangular ducts. The second normal stress generating a secondary flow is modeled by adopting the Reiner-Rivlin constitutive equation and the calculated secondary flow showed good agreement with experiments. The primary velocity U as well as the pressure drop were not affected by the secondary flow in rectangular ducts, whose order of magnitude is less than 0.1% of the primary velocity. The small magnitude of the secondary flow, however, affect moderately the temperature fields. The calculated Nusselt numbers with secondary flow show 50% heat transfer enhancement over those of a purely viscous non-Newtonian fluid, which are considerably lower than the experimental values. Therefore, we conclude that there should be an additional heat transfer enhancement mechanism involved in the viscoelastic fluid such as temperature-dependence.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Review on the induced seismic event for artificial reservoir (인공저류층 생성을 위한 유도진동에 관한 사전연구)

  • Jeon, Jong-Ug;Myoung, Woo-Ho;Kim, Young-Deug
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.55-60
    • /
    • 2012
  • In many cases, geothemal wells will not be opened up a geothermal reservoir under such conditions that an extraction of geothermal energy is economically viable without any further measures. Geothermal wells often have to be stimulated, in order to increase productivity. For the non-volcanic area, such as Korea, the hydraulic stimulation is necessary to complete geothermal power plant. The analysis of induced seismic event showed that the thermal resource might have a much wider extent and a much higher generation potential than previously assumed. In order to record compressional and shear waves emitted during fracture stimulation, three-component geophones are placed in a seismometer. The recorded data from one seismometer is the convolution of the source magnitude, the transmission media, and the sensitivity of the instrument.

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

Effects of Clubhead Velocity on GRF Magnitude and Time during 7-iron Swing (골프스윙 시 지면반력 크기와 시간 차이가 클럽헤드 속도에 미치는 영향)

  • Woo, Byung Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.27-35
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the influence of clubhead velocity through regression analysis on the magnitude and time difference of the forward-backward, mediolateral, and vertical ground reaction peak forces generated by force plate during golf swing. Method: 16 subjects (age: 20.5±4.2 yrs, height: 176.0±5.4 cm, weight: 77.8±5.9 kg, handy: 2.4±1.7) who is elite golf player in high school and university, participated in this study. The study method adopted three-dimensional analysis with 8 cameras and ground reaction force measurement with two force plate. The analysis variables were clubhead velocity, and ground reaction analysis variables set four events in each graph based on the peak forces commonly generated in Fx, Fy, and Fz graphs of the ground reaction data during the golf swing. Results: As a result of analyzing the influence of ground reaction magnitude difference on clubhead velocity, the influence on clubhead velocity was ym4, zm1, xm4, zm2. The larger ym4, xm4, zm1, the fasterthe clubhead velocity, but the smallerthe zm2, the faster the clubhead velocity. And in time difference, the influence on the clubhead velocity was in the order of xt4, zt1, zt3. The shorter xt4, zt1, zt3 showed faster clubhead velocity. Conclusion: The leftfoot played a leading role in increasing the velocity of the clubhead. Although the result was caused by the interaction of the right foot and the left foot during the swing, the role of the left foot is relatively large.

A 4-Channel Multi-Rate VCSEL Driver with Automatic Power, Magnitude Calibration using High-Speed Time-Interleaved Flash-SAR ADC in 0.13 ㎛ CMOS

  • Cho, Sunghun;Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Pu, YoungGun;Yoo, Sang-Sun;Hwang, Keum Cheol;Yang, Youngoo;Park, Cheon-Seok;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.274-286
    • /
    • 2016
  • This paper presents a 4-channel multi-rate vertical-cavity surface-emitting laser (VCSEL) driver. In order to keep the output power constant with respect to the process, voltage, temperature (PVT) variations, this research proposes automatic power and magnitude. For the fast settling time, the high-speed 10-bit time-interleaved Flash-successive approximation analog to digital converter (Flash-SAR ADC) is proposed and shared for automatic power and magnitude calibration to reduce the die area and power consumption. This chip is fabricated using $0.13-{\mu}m$ CMOS technology and the die area is $4.2mm^2$. The power consumption is 117.84 mW per channel from a 3.3 V supply voltage at 10 Gbps. The measured resolution of bias /modulation current for APC/AMC is 0.015 mA.