• 제목/요약/키워드: Orbitrap MS analysis

검색결과 14건 처리시간 0.024초

온라인 자동화 시료 전처리 및 HR Orbitrap LC/ESI-MS를 이용한 환경시료 중 잔류 의약물질 분석방법 확립 (Establishment of the Analytical Method for Residual Pharmaceuticals in Raw Water Using Online Sample Preparation and High Resolution Orbitrap LC/ESI-MS)

  • 황윤정;신상희;박종숙
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.409-419
    • /
    • 2013
  • In this study, the analytical method for 27 residual pharmaceuticals in raw water was developed. Online sample preconcentration/extraction and analysis with high resolution Orbitrap mass spectrometry (LC-ESI/Orbitrap MS) were performed. The calibration curves showed good linearities (above $r^2$ = 0.998) in the range of 5 ~ 1,000 ng/L. The method detection limit and the limit of quantification were 1.1 ~ 10.0 ng/L and 3.4 ~ 31.7 ng/L, respectively. Recoveries of the target compounds were between 70.1% and 115.8% (except cefadroxil, cefradine, vancomycin, and iopromide (50.2 ~ 67.0%)). The optimized analytical method can be useful to determine the residual pharmaceuticals in raw water.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.

Rapid determination and quantification of hair-growth compounds in adulterated products by ultra HPLC coupled to quadrupole-orbitrap MS

  • Lee, Ji Hyun;Park, Han Na;Kang, Gihaeng;Kim, Nam Sook;Park, Seongsoo;Lee, Jongkook;Kang, Hoil
    • 분석과학
    • /
    • 제32권2호
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, a number of adulterated products, which are advertised as hair-growth enhancer have been emerged among those who suffer hair loss disease. For continuous control of illegal products, in this study, a rapid and sensitive method for simultaneous screening of 12 compounds that enhance hair-growth was established to protect public health by ultrahigh-performance liquid chromatography coupled to quadrupole-orbitrap mass spectrometry (UHPLC-Q-Orbitrap-MS). Fragmentation pathways of them were proposed based on $MS^2$ spectral data obtained using the established method. In this analysis, the LODs and LOQs ranged from 0.05 to 50 ng/mL and from 0.17 to 167 ng/mL, respectively. The square of the linear correlation coefficient ($R^2$) was determined as more than 0.995. The intra- and inter-assay accuracies were respective 88-112 % and 88-115 %. Their precision values were measured within 5 % (intra-day) and 10 % (inter-day). Mean recoveries of target compounds in adulterated products ranged from 84 to 115%. The relative standard deviation of stability was less than 12 % at $4^{\circ}C$ for 48 h. The method was employed to screen 14 dietary supplements advertised to be effective for the treatment of hair loss. Some of the products (~21 %) were proven to contain synthetic drugs that promote hair growth such as triaminodil, minoxidil, and finasteride.

Detection of phenobarbital adulteration in dietary supplements: simultaneous analysis of 16 sedative-hypnotics and sleep-inducers by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS)

  • Lee, Ji Hyun;Choi, Ji Yeon;Park, Hanna;Min, Ah Young;Kim, Nam Sook;Park, Seong Soo;Park, Sung-Kwan;Kang, Ho-il
    • 분석과학
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2019
  • The safety of food is occasionally questionable, as there have been some reports of products contaminated with illegal adulterants. In this study, the presence of 16 sedative-hypnotics and sleep inducers in dietary supplements was determined by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS). The UPLC method was validated, providing a linearity (R2) of more than 0.999, and LODs and LOQs that ranged from 0.2 to 0.5 and 0.6 to $1.5{\mu}g\;mL^{-1}$, respectively. The repeatabilities were 0.2-8.4 % (intra-day) and 0.3-4.5 % (inter-day), and the accuracies were 89.0-117.0 % (intra-day) and 87.8-111.9 % (inter-day). The mean recoveries of the spiked samples ranged from 98.7 to 107.3 %. The relative standard deviation (%RSD) of the stability was less than 2.4 %. Using the developed method, one sedative-hypnotic compound, phenobarbital, was detected in one of the nineteen samples tested. In addition, the major characteristic fragment ions of each target compound were confirmed using Q-Orbitrap-MS for higher accuracy. Monitoring the presence of these 16 sedative-hypnotics and sleep inducers in dietary supplements should be pursued in the interest of human health, and the results of this study confirmed that the developed method has value for this application.

오비트랩 고분해능 질량분석기를 이용한 폐사 조류 중 다성분 잔류 농약 스크리닝 기법 (Residual Multi Pesticides Screening of Dead Birds by Orbitrap High Resolution Mass Spectrometry)

  • 이두희;김보경;왕승준;손기동;정현미;최종우
    • 한국환경농학회지
    • /
    • 제36권4호
    • /
    • pp.269-278
    • /
    • 2017
  • BACKGROUND: The objective of this study was to evaluate screening method of residual multi pesticides in dead birds by Orbitrap high resolution mass spectrometry (HRMS) to identify the cause of death for birds. METHODS AND RESULTS: Extraction and clean-up method of residual pesticides in liver of dead birds was used QuEChERS (Quick Easy Cheap Effective Rugged and Safe) and method validations was conducted using liquid chromatography and gas chroamtography with triple-quadrupole mass spectrometer (LC/MS/MS and GC/MS/MS) Also, we were evaluated screening method for the determination of residual pesticides in liver of dead birds by LC and GC Orbitrap Mass Spectrometry. Results of method validations, Correlation coefficients of the matrix matched calibration curves were >0.978, and the method detection limits (MDLs) and limits of quantitation (LOQ) were 2.8~72.1 ng/g (18.4 ng/g on average) and 9.0~230 ng/g (58.5 ng/g on average). The accuracy ranged from 69.1%to 130% (103% on average), and the precision values were less than 14.8%(3.8%on average). The screening of residual pesticides in liver of dead birds by LC and GC Orbitrap HRMS was detected monocrotophos, carbofuran, carbosulfan, deltametrin, benfuracarb, carbofuran, phosphamidon, prochloraz in investigated samples. CONCLUSION: This results showed that accurate mass were extraction of residual pesticides in dead birds by Orbitrap HRMS. It suggested that this screening method is applicable to the residual pesticide analysis for the cause of death as a main tool.

Performance evaluation of organic matter adsorption from actual graywater using GAC: OrbitrapTM MS and optimization

  • Ligaray, Mayzonee;Kim, Minjeong;Shim, Jaegyu;Park, Jongkwan;Cho, Kyung Hwa
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.471-484
    • /
    • 2019
  • The complex combination of organic contaminants in the wastewater made water treatment challenging; hence, organic matter in water bodies is usually measured in terms of organic carbon. Since it is important to identify the types of compounds when deciding suitable treatment methods, this study implemented a quantitative and qualitative analysis of the organic matter content in an actual graywater sample from Ulsan, Republic of Korea using mass spectroscopy (MS). The graywater was treated using adsorption to remove the organic contaminants. Using orbitrap MS, the organic matter content between an untreated graywater and the treated effluent were compared which yielded a significant formula count difference for the samples. It was revealed that CHON formula has the highest removal count. Isotherm studies found that the Freundlich equation was the best fit with a coefficient of determination ($R^2$) of 0.9705 indicating a heterogenous GAC surface with a multilayer characteristic. Kinetics experiments fit the pseudo-second order equation with an $R^2$ of 0.9998 implying that chemisorption is the rate-determining step between the organic compounds and GAC at rate constant of $52.53g/mg{\cdot}h$. At low temperatures, the reaction between GAC and organic compounds were found to be spontaneous and exothermic. The conditions for optimization were set to achieve a maximum DOC and TN removal which yielded removal percentages of 94.59% and 80.75% for the DOC and TN, respectively. The optimum parameter values are the following: pH 6.3, 2.46 g of GAC for every 30 mL of graywater sample, 23.39 hrs contact time and $38.6^{\circ}C$.

온라인 시료주입과 UPLC-Orbitrap 질량분석법을 이용한 수질 조류독소의 고속분석방법 개발 및 환경시료적용 (Fast and Accurate Determination of Algal Toxins in Water using Online Preconcentration and UPLC-Orbitrap Mass Spectrometry)

  • 장제헌;김윤석;최재원
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.843-850
    • /
    • 2012
  • Due to the fast response to algae bloom issue in drinking water treatment plant, very fast determination methodology for algal toxin is required. In this study, column switching technique based online preconcentration method was combined with high resolution full scan mass spectrometer to save sample preparation time and to obtain fast and accurate result. After parameter optimization of online preconcentration, 1mL filtered sample was directly injected to trap column with switching valve system. Next, target toxins are eluted by 98% acetonitrile and analysed with 150 - 1,100 amu scan range at 50,000 resolving power. Method detection limit (MDL) for microcystin-LR, the most toxic isomer, was 0.1 ng/mL and others such as microcystin-YR, microcystin-RR and nodularin were 0.08, 0.03 and 0.04 ng/mL, respectively. This is the best improved sensitivities with 1mL volume in the literature. Furthermore, due to the use of ultra pressure HPLC (UPLC), the whole method run was completed in 4 min. Real sample applications for 173 sample including 55 surface water and 118 treatment plant samples for raw and treated water could be done within 16 hours. In our calculation, this methodology is roughly 80% faster than the previous manual solid-phase extraction with LC-MS/MS method.

LC-MS/MS를 이용한 단백질 의약품 맵핑 교수법 (Educational Peptide Mapping of Protein-based Biopharmaceuticals by using LC-MS/MS)

  • 김준석
    • 실천공학교육논문지
    • /
    • 제14권2호
    • /
    • pp.327-332
    • /
    • 2022
  • 본 실험은 효용성이 넓어지고 있는 바이오의약품 시장에서 질량분석기를 이용한 정밀 분석법을 제시한다. 단백질 의약품인 인성장호르몬(Somatotopin)을 분석하는 다양한 기술 중, 생화학적 시료 전처리를 통해 펩티드화 시킨 단백질을 LC-MS/MS 분석법으로 분석하였다. 분석과정은 액체크로마토그래피를 이용한 분리분석과 질량분석을 이용한 MS 및 MS/MS 분석으로 수행하였다. 인성장호르몬의 경우 21개의 트립틱 펩티드로 절단할 수 있는데, 본 실험을 통해 이들 중 13개의 펩티드가 평균 1 ppm 에러 이내로 이론적 예측치와 일치하였다.

Analysis of oligosaccharides from Panax ginseng by using solid-phase permethylation method combined with ultra-high-performance liquid chromatography-Q-Orbitrap/mass spectrometry

  • Li, Lele;Ma, Li;Guo, Yunlong;Liu, Wenlong;Wang, Yang;Liu, Shuying
    • Journal of Ginseng Research
    • /
    • 제44권6호
    • /
    • pp.775-783
    • /
    • 2020
  • Background: The reports about valuable oligosaccharides in ginseng are quite limited. There is an urgent need to develop a practical procedure to detect and analyze ginseng oligosaccharides. Methods: The oligosaccharide extracts from ginseng were permethylated by solid-phase methylation method and then were analyzed by ultra-high-performance liquid chromatography-Q-Orbitrap/MS. The sequence, linkage, and configuration information of oligosaccharides were determined by using accurate m/z value and tandem mass information. Several standard references were used to further confirm the identification. The oligosaccharide composition in white ginseng and red ginseng was compared using a multivariate statistical analysis method. Results: The nonreducing oligosaccharide erlose among 12 oligosaccharides identified was reported for the first time in ginseng. In the comparison of the oligosaccharide extracts from white ginseng and red ginseng, a clear separation was observed in the partial least squares-discriminate analysis score plot, indicating the sugar differences in these two kinds of ginseng samples. The glycans with variable importance in the projection value large than 1.0 were considered to contribute most to the classification. The contents of oligosaccharides in red ginseng were lower than those in white ginseng, and the contents of maltose, maltotriose, maltotetraose, maltopentaose, maltohexaose, maltoheptaose, maltooctaose, maltononaose, sucrose, and erlose decreased significantly (p < 0.05) in red ginseng. Conclusion: A solid-phase methylation method combined with liquid chromatography-tandem mass spectrometry was successfully applied to analyze the oligosaccharides in ginseng extracts, which provides the possibility for holistic evaluation of ginseng oligosaccharides. The comparison of oligosaccharide composition of white ginseng and red ginseng could help understand the differences in pharmacological activities between these two kinds of ginseng samples from the perspective of glycans.

Bidirectional Interactions between Green Tea (GT) Polyphenols and Human Gut Bacteria

  • Se Rin Choi;Hyunji Lee;Digar Singh;Donghyun Cho;Jin-Oh Chung;Jong-Hwa Roh;Wan-Gi Kim;Choong Hwan Lee
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권10호
    • /
    • pp.1317-1328
    • /
    • 2023
  • Green tea (GT) polyphenols undergo extensive metabolism within gastrointestinal tract (GIT), where their derivatives compounds potentially modulate the gut microbiome. This biotransformation process involves a cascade of exclusive gut microbial enzymes which chemically modify the GT polyphenols influencing both their bioactivity and bioavailability in host. Herein, we examined the in vitro interactions between 37 different human gut microbiota and the GT polyphenols. UHPLC-LTQ-Orbitrap-MS/MS analysis of the culture broth extracts unravel that genera Adlercreutzia, Eggerthella and Lactiplantibacillus plantarum KACC11451 promoted C-ring opening reaction in GT catechins. In addition, L. plantarum also hydrolyzed catechin galloyl esters to produce gallic acid and pyrogallol, and also converted flavonoid glycosides to their aglycone derivatives. Biotransformation of GT polyphenols into derivative compounds enhanced their antioxidant bioactivities in culture broth extracts. Considering the effects of GT polyphenols on specific growth rates of gut bacteria, we noted that GT polyphenols and their derivate compounds inhibited most species in phylum Actinobacteria, Bacteroides, and Firmicutes except genus Lactobacillus. The present study delineates the likely mechanisms involved in the metabolism and bioavailability of GT polyphenols upon exposure to gut microbiota. Further, widening this workflow to understand the metabolism of various other dietary polyphenols can unravel their biotransformation mechanisms and associated functions in human GIT.