• Title/Summary/Keyword: Orbital wall defect

검색결과 29건 처리시간 0.02초

Orbital wall restoring surgery with primary orbital wall fragments in blowout fracture

  • Kang, Dong Hee
    • 대한두개안면성형외과학회지
    • /
    • 제20권6호
    • /
    • pp.347-353
    • /
    • 2019
  • Most orbital surgeons believe that it's difficult to restore the primary orbital wall to its previous position and that the orbital wall is so thin that cannot be firmly its primary position. Therefore, orbital wall fractures generally have been reconstructed by replacing the bony defect with a synthetic implant. Although synthetic implants have sufficient strength to maintain their shape and position in the orbital cavity, replacement surgery has some drawbacks due to the residual permanent implants. In previous studies, the author has reported an orbital wall restoring technique in which the primary orbital wall fragment was restored to its prior position through a combination of the transorbital and transantral approaches. Simple straight and curved elevators were introduced transnasally to restore the orbital wall and to maintain temporary extraorbital support in the maxillary and ethmoid sinus. A transconjunctival approach provided sufficient space for implant insertion, while the transnasal approach enabled restoration of the herniated soft tissue back into the orbit. Fracture defect was reduced by restoring the primary orbital wall fragment to its primary position, making it possible to use relatively small size implant, furthermore, extraorbital support from both sinuses decreased the incidence of implant displacement. The author could recreate a natural shape of the orbit with the patient's own orbital bone fragments with this dual approach and effectively restored the orbital volume and shape. This procedure has the advantages for retrieving the orbital contents and restoring the primary orbital wall to its prior position.

얼굴뼈 CT 계측 모형을 이용한 안와벽골절의 재건 (Orbital Wall Reconstruction by Copying a Template (defect model) from the Facial CT in Blow-out Fracture)

  • 김재근;유선혜;황건;황진희
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: Recently, orbital wall fracture is common injuries in the face. Facial CT is essential for the accurate diagnosis and appropriate treatment to reconstruct of the orbital wall. The objective of this study was to report the method for accurate measurement of area and shape of the bony defect in the blow-out fractures using facial CT in prior to surgery. Methods: The authors experienced 46 cases of orbital wall fractures and examined for diplopia, sensory disturbance in the area of distribution of the infraorbital nerve, and enophthalmos in the preoperation and followed 1 months after surgery, from August 2007 to May 2008. Bony defect was predicted by measuring continuous defect size from 3 mm interval facial CT. Copying from the defect model (template), we reconstructed orbital wall with resorbable sheet (Inion $CPS^{(R)}$ Inion Oy, Tampere, Finland). Results: One months after surgery using this method, 26 (100%) of the 26 patients improved in the diplopia and sensory disturbance in the area of distribution of the infraorbital nerve. Also 8 (72.7%) of the 11 patients had enophthalmos took favorable turn. Conclusion: This accurate and time-saving method is practicable for determining the location, shape and size of the bony defect. Using this method, we can reconstruct orbital wall fracture fastly and precisely.

The Correlation between the Degree of Enophthalmos and the Extent of Fracture in Medial Orbital Wall Fracture Left Untreated for Over Six Months: A Retrospective Analysis of 81 Cases at a Single Institution

  • Sung, Yun Sik;Chung, Chan Min;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.335-340
    • /
    • 2013
  • Background In patients with medial orbital wall fracture, predicting the correlation between the degree of enophthalmos and the extent of fracture is essential for deciding on surgical treatment. We conducted this retrospective study to identify the correlation between the two parameters. Methods We quantitatively analyzed the correlation between the area of the bone defect and the degree of enophthalmos on computed tomography scans in 81 patients with medial orbital wall fracture who had been left untreated for more than six months. Results There was a significant linear positive correlation between the area of the medial orbital wall fracture and the degree of enophthalmos with a formula of E=0.705A+0.061 (E, the degree of enophthalmos; A, the area of bone defect) (Pearson's correlation coefficient, 0.812) (P<0.05). In addition, that there were no cases in which the degree of enophthalmos was greater than 2 mm when the area of the medial orbital wall fracture was smaller than $1.90cm^2$. Conclusions Our results indicate not only that 2 mm of enophthalmos corresponds to a bone defect area of approximately $2.75cm^2$ in patients with medial orbital wall fracture but also that the degree of enophthalmos could be quantitatively predicted based on the area of the bone defect even more than six months after trauma.

Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

  • Cha, Jong Hyun;Moon, Myeong Ho;Lee, Yong Hae;Koh, In Chang;Kim, Kyu Nam;Kim, Chang Gyun;Kim, Hoon
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.26-33
    • /
    • 2017
  • Background The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. Methods This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30) or the medial wall (group M, n=30). The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters. Results Varying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568-0.788; $R^2=32.2%-62.1%$). Conclusions Both the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>$0.9cm^3$) occurred not infrequently despite the presence of a small orbital defect (<$1.9cm^2$). Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

Endoscopic slide-in orbital wall reconstruction for isolated medial blowout fractures

  • Kim, Taewoon;Kim, Baek-Kyu
    • 대한두개안면성형외과학회지
    • /
    • 제21권6호
    • /
    • pp.345-350
    • /
    • 2020
  • Background: This study evaluated the efficacy of the endoscopic medial orbital wall repair by comparing it with the conventional transcaruncular method. This surgical approach differs from the established endoscopic technique in that we push the mesh inside the orbit rather than placing it over the defect. Methods: We retrospectively reviewed 40 patients with isolated medial orbital blowout fractures who underwent medial orbital wall reconstruction. Twenty-six patients underwent endoscopic repair, and 14 patients underwent external repair. All patients had preoperative computed tomography scans taken to determine the defect size. Pre- and postoperative exophthalmometry, operation time, the existence of diplopia, and pain were evaluated and compared between the two methods. We present a case showing our procedure. Results: The operation time was significantly shorter in the endoscopic group (44.7 minutes vs. 73.9 minutes, p= 0.035). The preoperative defect size, enophthalmos correction rate, and pain did not significantly differ between the two groups. All patients with preoperative diplopia, eyeball movement limitation, or enophthalmos had their symptoms resolved, except for one patient who had preexisting strabismus. Conclusion: This study demonstrates that endoscopic medial orbital wall repair is not inferior to the transcaruncular method. The endoscopic approach seems to reduce the operation time, probably because the dissection process is shorter, and no wound repair is needed. Compared to the previous endoscopic method, our method is not complicated, and is more physiological. Larger scale studies should be performed for validation.

내시경을 이용한 비강내 접근법과 속눈썹밑 절개를 동시에 이용한 안와내벽 재건술 (Two Portal Approach(Endoscopic Transnasal and Subciliary) in Medial Orbital Wall Fracture)

  • 장현;동은상;원창훈;윤을식
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.552-556
    • /
    • 2006
  • Purpose: As the use of computed tomographic scanning spread, the diagnosis of blow-out fractures of the medial orbital wall increased. Conventionally, the surgery of blow-out fractures in medial orbital wall was performed by various approaches with external incision or endoscopic approach. Although the field of orbital surgery has progressed significantly during the last decade, accurate realignment and replacement of component is difficult due to lack of visualization of the fracture site, blind dissection of the orbital wall, and difficulty in insertion of implant. In order to overcome these shortcomings, we explored the use of endoscopic transnasal approach together with subciliary approach. Methods: The entrapped periorbital tissues in the ethmoid sinus were completely reduced endoscopically, and the bone defect of medial orbital wall was reconstructed with $Medpor^{(R)}$ insertion via subciliary approach. This technique was applied to 13 patients who had medial orbital wall fracture. Results: The patients were followed-up for 3 to 24 months with an average of 9 months. The postoperative courses were satisfactory in all cases. Conclusion: The conjunction of endoscopic transnasal and subciliary approach technique seems to produce good results in medial orbital wall fracture.

혈행화된 부분층 두개골피판을 이용한 상악골 종양 적출 환자에서의 안와하벽 재건술 증례 (Inferior Orbital Wall Reconstruction with Vascularized Partial Thickness Calvarial Bone Flap in Three Cases of Maxillary Tumor)

  • 신상호;이윤정;김준식;김남균;이경석
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.49-54
    • /
    • 2009
  • 상악골 악성종양의 경우 적출 후 골편들을 이식해 상악동 전체를 재건하는 경우는 재발이 많아 잘 시행하지 않는다. 이러한 이유로 안와하연의 재건을 통해 안구 및 안면윤곽만을 재건하는데, 저자들이 시행한 혈행화된 부분 두께의 골이식(vascularized split thickeness calvarium)은 술기방법에 있어 골피판이 혈관경에서 쉽게 분리되는 성질이 있어 시행에 주의가 필요하고 혈관경을 포함한 temporalis muscle이 부피감을 주므로 미용상 불리한 점이 있는 반면에 골편의 높은 생존율이 보장된다는 장점과 공여부의 합병증이 적다는 장점을 가진다. 또한 술후 복시 현상이나 안구함몰이 관찰되지 않았다는 점이 합리적인 술기임을 지지해준다. 따라서 측두동맥 및 정맥을 혈관경으로 하는 혈행화된 두정골 부분층 이식술은 안와하벽을 재건하는데 있어 안전하게 시행가능 한 술기였음을 보고하는 바이다.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건 (Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture)

  • 정재아;공정식;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.

Micro-titanium mesh를 이용한 상악골 결손부의 재건술에 관한 연구 (THE RECONSTRUCTION OF THE MAXILLARY WALL DEFECT USING MICRO-TITANIUM MESH)

  • 김성곤;최유성;정필훈;이희철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권2호
    • /
    • pp.197-203
    • /
    • 2000
  • Maxillary defect may be induced by trauma, inflammation, cyst, tumor and surgical procedure. In case of limited wall defect, free bone graft has been preferred. But it has some problems such as postoperative bone resorption and soft tissue inclusion to recipient site. And we can not use free bone in the case who has inflammation in the donor site. So we used the micro-titanium mesh as reconstructive material for the maxillary wall defect. We had operated 8 patients who were diagnosed as maxillary partial defects from June 1997 to September 1998 in the Chin-Hae military hospital. They were 1 case of antral wall defect, 1 case of palatal wall defect, 5 cases of infra-orbital wall defects and 1 case of oroantral fistula case. As a result, the micro-titanium mesh has shown the morphological stability and biocompatibility and it could be used in case who has infection. And mesh structure could prevent soft tissue ingrowth to bony defect area. Thus it can be used to the case of maxillary partial defect successfully.

  • PDF