Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.

Reference dose levels for dental periapical radiography in Chonnam Province (전남 지방에서 치근단방사선사진의 참고 선량 수준)

  • Han, Mi-Ra;Kang, Byung-Cheol;Lee, Jae-Seo;Yoon, Suk-Ja;Kim, Young-Hee
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.195-198
    • /
    • 2009
  • Purpose : To establish reference doses of periapical radiography in Chonnam Province, Korea. Materials and Methods : The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. Results : The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. Conclusion : The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  • PDF

Fundamentals and Applications of Cone-Beam Computed Tomography(CBCT) (임상가를 위한 특집 1 - CBCT의 기본원리 및 적용)

  • Park, In-Woo
    • The Journal of the Korean dental association
    • /
    • v.50 no.4
    • /
    • pp.180-188
    • /
    • 2012
  • Cone beam computed tomography(CBCT) machines recently developed in Korea, being designed for imaging hard tissues of the oral and maxillofacial region. I reported a brief overview of CBCT system, in comparison with coventional computed tomography(CT) system. CBCT provides high resolution, simpler image acquisition, lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

Foramen transversarium enlargement caused by vertebral artery tortuosity: Diagnosis with cone-beam computed tomography and magnetic resonance angiography

  • Omami, Galal
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.329-332
    • /
    • 2021
  • A markedly enlarged foramen transversarium was discovered incidentally on a cone-beam computed tomography scan of a 72-year-old male patient who was referred for dental implant placement. Further evaluation with magnetic resonance angiography revealed that the foramen enlargement was caused by a tortuosity in the course of the vertebral artery. This case report highlights the importance of recognizing significant incidental findings on diagnostic images and the potential need for additional imaging as part of the complete interpretative process.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study

  • Shahmirzadi, Solaleh;Sharaf, Rana A.;Saadat, Sarang;Moore, William S.;Geha, Hassem;Tamimi, Dania;Kocasarac, Husniye Demirturk
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Purpose: The aim of this study was to assess artifacts generated in cone-beam computed tomography (CBCT) of 3 types of dental implants using 3 metal artifact reduction (MAR) algorithm conditions (pre-acquisition MAR, post-acquisition MAR, and no MAR), and 2 peak kilovoltage (kVp) settings. Materials and Methods: Titanium-zirconium, titanium, and zirconium alloy implants were placed in a dry mandible. CBCT images were acquired using 84 and 90 kVp and at normal resolution for all 3 MAR conditions. The images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the intensity of artifacts for each combination of material and settings. A 3-factor analysis of variance model with up to 3-way interactions was used to determine whether there was a statistically significant difference in the mean intensity of artifacts associated with each factor. Results: The analysis of all 3 MAR conditions showed that using no MAR resulted in substantially more severe artifacts than either of the 2 MAR algorithms for the 3 implant materials; however, there were no significant differences between pre- and post-acquisition MAR. The 90 kVp setting generated less intense artifacts on average than the 84 kVp setting. The titanium-zirconium alloy generated significantly less intense artifacts than zirconium. Titanium generated artifacts at an intermediate level relative to the other 2 implant materials, but was not statistically significantly different from either. Conclusion: This in vitro study suggests that artifacts can be minimized by using a titanium-zirconium alloy at the 90 kVp setting, with either MAR setting.

Comparison of cone beam CT and conventional CT in absorbed and effective dose (Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가)

  • Kim, Sang-Yeon;Han, Jin-Woo;Park, In-Woo
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

Incidental findings in a consecutive series of digital panoramic radiographs

  • MacDonald, David;Yu, Warrick
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.53-64
    • /
    • 2020
  • Purpose: The aim of this study was to determine the prevalence of incidental findings(IFs) on digital dental panoramic radiographs(DPRs) of asymptomatic patients attending a general dental practice. Materials and Methods: This was a retrospective study of 6,252 consecutive digital (photostimulatable phosphor) DPRs of patients who visited a Canadian general dental practice for a complete new patient examination. The IFs were grouped into dental-related anomalies, radiopacities and radiopacities in the jaws, changes in the shape of the condyles, and other findings in the jaws, such as tonsilloliths and mucosal antral pseudocysts. Their prevalence was determined. Results: Thirty-two percent of the DPRs showed at least 1 IF. The highest prevalence was found for dental-related anomalies(29% of all DPRs), of which impacted teeth were the most prevalent finding (24% of all DPRs), followed by idiopathic osteosclerosis(6% of all DPRs). A lower prevalence was noted for tonsilloliths(3%), and the prevalence of root tips, mucosal antral pseudocysts, and anomalies in condylar shape was approximately 1% each. Conclusion: The observed prevalence of 32.1% for IFs of any type underscores the need for a dental practitioner to review the entire DPR when a patient presents for an initial dental examination (or check-up) or for dental hygiene. Only a single IF (a central giant cell granuloma) provoked alarm, as it was initially considered malignant. Similarly, impacted teeth and suspected cysts need careful evaluation upon discovery to determine how they may be optimally managed.

Eustachian tube calcification as an unusual finding on a panoramic radiograph

  • Galal Omami
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.105-107
    • /
    • 2024
  • The author herein presents an unusual case of eustachian tube calcification masquerading as loose radiopacities in the temporomandibular joints on a panoramic image, creating a diagnostic challenge. The patient, a 72-year-old woman, presented to the dental service for implant treatment to improve her masticatory function. A cone-beam computed tomography scan was performed and reviewed by a board-certified oral and maxillofacial radiologist. The scan showed no evidence of calcifications in the temporomandibular joints; however, it revealed nodular calcifications within the cartilaginous portion of the eustachian tube bilaterally. Additionally, this report briefly reviews the differential diagnosis of calcified loose bodies in the temporomandibular joint and provides information that needs to be reinforced periodically.