• 제목/요약/키워드: Optimal operation conditions

검색결과 463건 처리시간 0.032초

메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석 (Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration)

  • 조창환;김용찬;장영수
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전시 적정 피뢰기 위치에 관한 연구 (A Study on the Optimal Position of Lightning Arrester on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;장화윤;안천용;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.535-536
    • /
    • 2011
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems and analyzes the optimal position of lightning arrester on joint operation of neutral wire and overhead grounding wire. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as location and current types of lightning stroke. Over voltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

  • PDF

이상홍수를 고려한 퍼지 최적 저수지 운영 (Fuzzy Optimal Reservoir Operation Considering Abnormal Flood)

  • 최창원;유명수;이재응
    • 대한토목학회논문집
    • /
    • 제32권4B호
    • /
    • pp.221-232
    • /
    • 2012
  • 본 연구에서는 이상홍수 발생 시 저수지의 안전성을 확보함과 동시에 두 개의 저수지를 효율적으로 연계운영하여 하류의 홍수피해를 줄이기 위한 모형을 개발하였다. 이상홍수 발생 시 저수지 최적연계운영을 위해 선형계획법을 사용하였고, 저수지 운영에서 유입량, 저수지 수위, 유입량의 증감 등의 요소에 포함된 불확실성을 해결하기 위해 퍼지제어기법을 도입하였다. 선형계획법을 이용하여 이상홍수 유입에 따른 저수지 최적연계운영규칙을 찾아내고, 퍼지제어기법을 사용하여 신속하고 정교한 운영이 요구되는 이상홍수 유입상황에 사용할 수 있는 모형을 개발하였다. 본 연구에서는 낙동강 상류에 위치한 안동댐과 임하댐을 대상으로 각 댐의 저수지에 100년 빈도의 홍수와 PMF가 유입될 때 안동시의 계획홍수량을 초과하지 않도록 저수지최적연계운영을 실시하였고, 최적연계운영규칙과 퍼지제어기법을 사용하여 댐 하류지점의 유량과 각 댐별 저류량, 유입량, 유입량의 증감에 따라 방류량을 결정하는 모형을 개발하였다. 개발된 모형은 안동댐과 임하댐의 각 저수지 및 안동시의 유황에 따라 결정되는 224개의 퍼지규칙으로 정리되었으며, GUI를 통해 현재 유황을 입력하면 각 댐의 방류량을 간단히 결정할 수 있다.

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

SC-OPF의 민감도 계수를 이용한 발전기 기동.정지계획 (The Unit Commitment Using the Sensitivity Factor of Security Constrained Optimal Power Flow)

  • 김광모;정구형;한석만;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.416-417
    • /
    • 2006
  • The recent movement to deregulated and competitive electricity market requires new concepts against existing central dispatch in the system operation and planning. As power systems tend to be operated more closely to their ultimate ratings, the role of SCOPF(Security Constrained Optimal Power Flow) is changed. This paper deals with the proper Unit Commitment condition changed according to the conditions or configuration of power system. This goal of is paper is to obtain proper security and Optimal UC condition through the efficient usage of the sensitivity Factor against critical contingencies. The proposed mechanism has been tested on a sample system and results show more secure conditions against critical contingencies.

  • PDF

이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구 (Operating characteristics of an air cooling PEMFC for portable application)

  • 손영준;박구곤;양태현;윤영기;이원용;임성대;김창수
    • 신재생에너지
    • /
    • 제1권1호
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF

대구 지하철 구간내 선형 변동에 따른 소음 및 진동 저감 방안 연구 (The optimal control methods to reduce the environmental hazards surrounding the YoungNam Uni. Rotary of City Taegu constructing Subway Line No.1)

  • 지왕률;최재진;강상수;강대우
    • 터널과지하공간
    • /
    • 제7권2호
    • /
    • pp.116-129
    • /
    • 1997
  • The objective of this study is to predict the minimization effect of the noise and vibration during the construction and the train operation regarding to the design modification of the Taegu Subway Line No. 1. It was suggested optimal control blasting methods to reduce the causing vibration Nuance to the resident in City Taegu and also proposed the better governing method to decrease the environmental hazard to the near buildings and residents during the train operation. When the high-density gaseous reaction of explosion products exerts a high pressure in motion outward, a dynamic stress field will be created in the surrounding buildings. Therefore, in the region close to the charge, permanent damage begins to occur at a great critical level of partial velocity, that is difficult from different structure as working conditions. It is reliable to predict that the damages could be reduced if we know the peak velocity and the exact reasons through the conducting of detail studies of structural analysis of the related buildings with the optimal blasting designs. A blasting technique should be deemed to take advantage of the reduction of damage of the surrounding rocks and structures to improve the in-city blasting. This is a typical in-city blasting operation where success depends on closely controlling the ground vibrations in case of better designed blasting methods. There are techniques that can be applied to prevent large vibrations from damaging the important buildings through the Route Modification of the Taegu Subway Line No. 1.

  • PDF

설비교체의 최적시기 결정에 관하여 (On the Optimal time for Renewal of Facilities)

  • 최은재
    • 한국국방경영분석학회지
    • /
    • 제3권1호
    • /
    • pp.109-114
    • /
    • 1977
  • There are some factors which cause the profits from the production to be decreased or increased. They are, for example, the rise in efficiency of production facilities resulting from the development of the scientific technique, the changes of purchase price of those, and the drop in efficiency of those owing to there long-term operation. In this connection, an manager can get the highest profit by deciding the proper time of new facilities replacement for those in operation or in being planned, which leads to good management planning of his manufactaring business for a given period or a long time. Main purpose of this is the study of how we decide the optimal time or facilities replacement in order to maximize the total profits for a given period by considering them as continous function as to the time in the case where a machineng is set. The results are following: 1. The definition of profit function is in duced in consideration of the breakdowns caused from continous operation of the machinery. 2. The necessary conditions are obtained for the optimal time of replacement and find out the methods of its solution. 3. Comparing between the 'Short cut' method and method in this paper, we obtained that our method is more realistic.

  • PDF

熱機關의 最適 運轉條件 (The optimal operation condition of heat engine)

  • 정평석;김수연
    • 대한기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.971-974
    • /
    • 1987
  • 본 연구에서는 최적설계를 위한 기초로서, 고정된 두 열원사이에서 작동하는 열기관을 예로 들어 운전조건에 따른 출력과 효율의 변화를 정성적으로 설명하여 출력 과 효율의 최대값이 극대값으로 나타남을 보이고, 경제적 측면에서 이들의 의의 및 경 제적 최적운전조건과의 관계 등을 고찰하려 한다.

김치생산용 알타리무 전처리가공시스템 개발(III) - 삭피장치의 개발 - (Development of the Altari Radish Pre-processing System for Kimchi Production(III) - Development of the Peeling Device -)

  • 민영봉;김성태;정태상
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.166-171
    • /
    • 2005
  • A prototype peeling device with rotating cutter blades was designed to peel altari radish skin. With the designed blades, the maximum peeling depth increased as the cutter clearance increased but the effect of the peeling speed was not significant. The optimal operating conditions for peeling was; the peeling speed was at 0.19m/s when peeled 2.5 blades/sec and the maximum peeling depth was 1.5mm, the minimum peeling depth was 0.5mm, and the leaf rotating speed was 12 rpm, respectively. In the peeling test fur the optimum operation conditions, with a auxiliary rolling device could adjust the rotational speed of the root uniformly, the altari radishes under 70mm diameter were peeled perfectly.