• Title/Summary/Keyword: Optimal facilities

Search Result 618, Processing Time 0.032 seconds

A study on an optimal design for a dual-band patch antenna with a shorting pin using the evolution strategy (진화 알고리즘을 이용한 단락핀이 있는 이중대역 패치 안테나 최적 설계 연구)

  • Ko, Jae-Hyeong;Kwon, So-Hyun;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.221-224
    • /
    • 2009
  • In this paper, we deal with the development of an optimal design program for a dual-band of 0.92 GHz and 2.45 GHz with shorting pin and slot by using evolution strategy. the optimal shorting pin, coaxial feed and H-shaped patch are determined by using an optimal design program based on the evolution strategy. To achieve this, an interface program between a commercial EM analysis tool and the optimal design program is constructed for implementing the evolution strategy technique that seeks a global optimum of the objective function through the iterative design process consisting of variation and reproduction. The resonance frequencies of the dual-band antenna yielded by the optimal design program are 0.92 GHz and 2.45 GHz that show a good agreement to the design target values.

  • PDF

A Study on the Optimal Grounding Design using Pattern Search Method for Electric Power Facilities (전력사용 시설물의 Pattern Search 법을 이용한 최적 접지 설계에 관한 연구)

  • 김경철;최병숙
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.58-66
    • /
    • 2002
  • Electric power facilities must have effective grounding to provide means to carry electric current into the earth under fault conditions and to prevent damage of equipment, ignition, and electrocution of personnel. This paper resent an algorithm called the Pattern Search method for the optimal parameters selection of the grounding system Simulation results using these parameters obtained from the PS method verify that the grounding systems are adequately designed.

Optimal deployment strategy of patriot missile (패트리어트 (patriot) 미사일의 최적 배치)

  • 김영휘;김성인;오원민
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1994.04a
    • /
    • pp.29-37
    • /
    • 1994
  • It is reported that north Korea has already developed 1,500 to 2,000-km-range Scud missile. As a defensive strategy against Scud attack on military and civilian facilities the military authorities are considering deployment of Patriot missile. This paper deals with its optimal deployment strategy. In this problem a Patriot missile which has multiple-facility responsibility may be able to protect each of its assigned facilities only with a certain probability, not absolute protection, and it may not be adequate to have only a single missile protect a facility, either because of its operational reliability or because of its limited availability at any given point in time. We formulate this problem into the probabilistic partial set covering model developed by Sherali and Kim. The applicability, verification and validation of the model are tested via an abbreviated case study.

OPTIMAL DESIGN MODEL FOR A DISTRIBUTED HIERARCHICAL NETWORK WITH FIXED-CHARGED FACILITIES

  • Yoon, Moon-Gil;Baek, Young-Ho;Tcha, Dong-Wan
    • Management Science and Financial Engineering
    • /
    • v.6 no.2
    • /
    • pp.29-45
    • /
    • 2000
  • We consider the design of a two-level telecommunication network having logical full-mesh/star topology, with the implementation of conduit systems taken together. The design problem is then viewed as consisting of three subproblems: locating hub facilities, placing a conduit network, and installing cables therein to configure the logical full-mesh/star network. Without partitioning into subproblems as done in the conventional approach, the whole problem is directly dealt with in a single integrated framework, inspired by some recent successes with the approach. We successfully formulate the problem as a variant of the classical multicommodity flow model for the fixed charge network design problem, aided by network augmentation, judicious commodity definition, and some flow restrictions. With our optimal model, we solve some randomly generated sample problems by using CPLEX MIP program. From the computational experiments, it seems that our model can be applied to the practical problem effectively.

  • PDF

Power Supply Considering load Characteristics and Eletricity Usage Pattern of Domestic Remote Islands (계통비연계 도서지역의 수요특성과 패턴분석에 따른 전력보급방안)

  • Jo, I.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.432-434
    • /
    • 2002
  • Recently, electricity demand of remote islands in Korea has been rapidly increased. It's mainly due to increase of income level resulted from economic development. Electricity demand patterns and characteristics in remote islands are different from those of mainland in point of time of peak load, demographic and industrial characteristics of islands, and so on. The optimal power supply in remote islands has a important relationship with accurate analysis of island's load characteristics, the adoption of relevant load forecasting technique, and optimal power facilities reflecting local's electricity demand characteristics. This paper shows the recent load pattern and characteristics, load forecasting using probability distribution, and the perpetration of relevant power facilities in remote islands.

  • PDF

A Study on the Optimal Investment Method for Distribution Systems Interconnected with Dispersed Generations (분산전원이 연계된 배전계통의 최적 설비투자 방안에 관한 연구)

  • Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2179-2185
    • /
    • 2008
  • This paper deals with the optimal investment method for distribution facilities, based on the analytical approach for the reliability assessment in distribution systems interconnected with new dispersed generations. The existing approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP(Non-Delivery Power) and NDE(Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of dispersed generations. The results from a case study show that the proposed methods can be a practical tool for the voltage management in distribution systems including dispersed sources.

An Analysis of Hyd-Cylinder Shop Facilities Planning by Simulation (시뮬레이션 기법을 이용한 유압생산부 설비배치 계획의 분석)

  • Chung, K.H.;Chung, S.W.;Park, D.H.;Kim, J.C.;Kwon, K.Y.
    • IE interfaces
    • /
    • v.5 no.2
    • /
    • pp.39-52
    • /
    • 1992
  • This paper presents alternatives for facilities planning and analyses them using simulation approach. For this purpose, hydro-cylinder production line was sampled as a case study. Several facilities planning alternatives are evaluated based on the several factors such as line balancing, equipment utilization, optimum number of equipments, inventory size, flow time, bottleneck machine, and productive capacity. An optimal facilities planning is proposed based on the degree of meeting with the all factors evaluated. The simulation language employed in this study is SIMAN and the data used for simulation are provided by hydro-cylinder shop.

  • PDF

Role of Senior Program for Financial Independence in Culture and Art Facility (문화예술시설의 재정적 독립방안의 관점에서 시니어프로그램의 역할)

  • Ahn, Pilyun
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.2
    • /
    • pp.345-359
    • /
    • 2020
  • Purpose: Financial independence of the museum is an urgent issue in Korea. In this paper, methodology to combine arts and culture facilities with senior society is investigated based on case study of various senior programs in other countries. Methods: In this paper, case study of various senior programs from cultural and arts facilities in other countries are investigated in the aspect of public nature and independent management. Based on the analysis of the case study, optimal methodology is derived. Results: Based on case study of various senior program in other countries, it is clear that art and cultural facilities play important roles in participating elderly people to various social activities through developing programs specialized for elderly people. Conclusion: From analysis of the case study, senior program from arts and culture facilities provides more familiar contents rather than professional contents. Also, they consider more on communication and cooperation with local society to develop the senior program, which fulfill both public nature and financial independence.

A Study on the Guidelines for Demand Factor of Electrical Facilities in Subway Stations (지하철 역사전기설비의 수용률 기준설정에 관한 연구)

  • Jang, Su-Yong;Kim, Hak-Lyun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.844-849
    • /
    • 2006
  • The electric facilities for subway stations require reliable and safe electricity in spite of their load increases rapidly. Nevertheless, Korea Electrical Safety Corporation reports that the accidents of independent electric facilities increased greatly from 4,632 cases in 1998 to 6,024 in 1999 and 6,776 cases in 2000, while the ratio of the accidents related with transformers grew gradually. As it is, it is deemed very important to minimize the spreading effects of the electric system accidents and thereby, enhance reliability of the electric supply as well as its safety. According to the fact that the electric facilities for subway stations are important for the public safety and conveniences, it should be careful to set their capacity instead of simply applying the general capacity standard to them, and thereby, improve their economy as well as prevent their accidents. With such a basic conception in mind, this study is aimed at analyzing the characteristics of the electric load in the subway stations and thereupon, suggesting some guidelines for setting of the electric facility capacity for subway stations in terms of optimal operation and safety.

  • PDF

A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus (초고압 중전기기 절연시험설비 성능개선 연구)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF