• 제목/요약/키워드: Optimal Pressure Control

검색결과 240건 처리시간 0.037초

판재 액압성형 공정에서의 최적압력곡선에 관한 연구 (A Study on the Optimal Pressure Curve for the Sheet Hydroforming)

  • 심현보;양희태;서의권;양동열
    • 소성∙가공
    • /
    • 제11권3호
    • /
    • pp.246-254
    • /
    • 2002
  • A simple method to derive an optimal pressure curve, characterized by initial pressure, final pressure and pressure path, has been proposed. The initial pressure has been determined from the condition to prevent recoiling phenomenon in the early stage, while the final pressure is from the FE analysis and pressure path is from the punch penetration volume. In order to realize the pressure curve, an open loop control system based on a proportional relief valve has been developed for the renovated CNC hydroforming press. Through the comparison of experiment and analysis, the predicted pressure curve has been verified optimal curve since no defect has been observed.

900L 냉장고 진공발포시스템 유압노즐의 최적 압력제어에 관한 연구 (A Study on Optimal Pressure Control of Hydraulic Nozzle for Vaccum Foam System of Refrigerator in the 900L Class)

  • 조상영;김민성;구영목;양준석;신행봉;한성현
    • 한국산업융합학회 논문집
    • /
    • 제19권2호
    • /
    • pp.50-61
    • /
    • 2016
  • This study proposes a new approach to control the nozzle pressure of homogenizer in refrigerator foam system in the 900L class. Generally, dynamic characteristics of the hydraulic nozzle system is highly nonlinear due to uncertain parameters, and it is very difficult to control of hydraulic dynamics. Firstly, it has been performed to derive a real-time control algorithm based on the mathematical model of hydraulic cylinder, and to estimate the values of the unknown parameter in the hydraulic system. Secondly, the feedback controller was designed to implement the optimal pressure control of the hydraulic nozzle system. Finally the control performance was illustrated by simulation.

오리피스를 이용한 고차압 제어 버터플라이 밸브의 캐비테이션 저감에 관한 연구 (A Study on Reduction of Cavitation with Orifice on High Differential Pressure Control Butterfly Valve)

  • 이상범
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.131-139
    • /
    • 2022
  • The exchange of goods over the sea is a situation in which the amount of trade between countries is gradually increasing. In order to maintain the optimal operating condition, the ship maintains stability and optimal operating conditions by inserting or withdrawing ballast water from the ballast tank according to the loading condition of cargo capacity is also increasing. Control valves play an important role in controlling fluid flow in these pipes. When the flow rate is controlled using a control valve, problems such as cavitation, flashing, and suffocating flow may occur due to high differential pressure, and in particular, damage to valves and pipes due to cavitation is a major problem. Therefore, in this study, the cavitation phenomenon is reduced by installing orifices at the front and rear ends of the high differential pressure control butterfly valve to reduce the sudden pressure drop at the limiting part of the butterfly valve step by step. The flow coefficient according to the shape of the orifice, the degree of cavitation occurrence, and the correlation were analyzed using a CFD(Cumputational Fluid Dynamics), and an optimal orifice design for reducing cavitation is derived.

급수 가압 멀티 펌프 시스템의 컨트롤러 개발 (Controller Development of Booster Multi-Pump System)

  • 이상균;이재춘;이병훈;황민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.382-384
    • /
    • 1996
  • This paper introduces the controller development of booster multi-pump system with constantly estimated control algorithm. Through analyzing by the experiment of optimal pressure with a certain flow rate. The larger pressure processing apparatus in microprocessor makes optimal water-supplying. This method is implemented with the only pure control algorithm without any other mechanical or circuitry apparatus. Also, Pump's life is lengthened by exchanging simple on, off and rotational inverter control. Optimal condition for pump is adjusted by the inverter control, and compact control panel helps the booster system install in real field.

  • PDF

CVT 변속속도 개선에 의한 엔진최적운전 (Optimal Engine Operation by Shift Speed Improvement for a CVT)

  • 이희라;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.546-551
    • /
    • 2001
  • In this paper, an algorithm to improve the optimal engine operation is suggested by increasing the CVT shift speed. By rearranging the CVT shift dynamic equation, it is found that the CVT shift speed depends on the line pressure as well as the primary pressure. Based on the shift dynamics, an algorithm to accomplish a faster shift speed is presented by increasing the line pressure. In order to apply the algorithm, dynamic models of the line pressure control valve and the ratio control valve are obtained by considering the CVT shift dynamics and model based controllers are designed. It is found from the simulation results that fuel economy can be improved by 2% in spite of the increased hydraulic loss due to the increased line pressure.

  • PDF

인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향 (Effect of Optimal Humidification for Extremely Low Birth Weight Infants During Nasal Continuous Positive Airway Pressure)

  • 김정숙;이은정
    • Child Health Nursing Research
    • /
    • 제17권2호
    • /
    • pp.145-152
    • /
    • 2011
  • Purpose: To evaluate the efficacy of Optimal humidification during Nasal Continuous Positive Airway Pressure (nCPAP) for Extremely Low Birth Weight Infant (ELBWI). Methods: The study design was a pre-test-post-test nonequivalent nonsynchronized quasi-experimental design. The participants were 218 ELBWI on nCPAP (experimental group: 102 and control group: 116). Data collection was conducted from January 2005 to April 2010. In order to measure and analyze the nCPAP duration, reintubation and nasal condition, Chi-square test and t-test were used. Results: Hypothesis 1, that the duration with nCPAP in the experimental group is longer than that of the control group and hypothesis 2-3, that the rate of reintubation and nasal problems in the experimental group are lower than the control group, were all supported as there were statistically significant differences between two groups. Conclusion: The findings suggest that the Optimal humidification in this study is an efficient intervention because it helps increase the last time of nCPAP with ELBWI and minimize complications. It is expected that Optimal humidification is beneficial and helpful in preventing and caring for respiratory problems in these infants.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

압력 조절 장치를 갖는 풍동 지면판에 관한 수치해석적 연구 (NUMERICAL STUDY ON WIND TUNNEL GROUND PLATE WITH A PRESSURE CONTROL DEVICE)

  • 이민재;김철완
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.53-59
    • /
    • 2010
  • Preliminary design of a ground plate, a device installed close to the aircraft model for wind tunnel test to simulate the ground effect, was performed by a numerical simulation. A two-dimensional numerical study was performed initially to decide the optimal leading edge and flap configurations. Then, three-dimensional studies were conducted to decide the optimal flap deflection angle for pressure distribution reduction since the plate and the plate supporting system generate static pressure difference between the upper and lower flow regions. Three-dimensional simulation additionally studied the effect of the clearance between the plate and the wind tunnel side wall. For the efficiency of computation, half model was simulated and a symmetric boundary condition was applied on the center plane. Based on the preliminary design, a ground plate was designed, manufactured and tested at the Korea Aerospace Research Institute(KARI) wind tunnel. The measured pressure differences versus flap deflection angle agreed well with the predicted results.

석탄화력 발전소 최적 변압운전 부하 범위 개선에 대한 연구 (A Study on the Improvement of Optimal Load Range for Sliding Pressure Operation of coal-fired Power Plant)

  • 이상훈;왕민석;위상봉;손영득
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.675-680
    • /
    • 2019
  • 석탄화력발전소는 저부하에서 효율 향상을 위해 변압운전으로, 고부하에서는 정압으로 운전하는 복합변압운전 방식으로 운전하고 있으며, 복합변압운전에는 2밸브 및 3밸브 전개모드로 구분되어 운영되고 있다. 각 발전소는 제작사 권고에 따라 터빈제어밸브 모드를 선택하여 운전하고 있으나 최적의 변압운전 부하범위로 운전되고 있지 않고, 각 발전소별 부하범위 또한 상이하게 구성 되어있다. 최적의 변압운전 부하범위로 설정되지 않으면 터빈밸브 교축 손실 발생에 따른 고압터빈 내부효율 저하가 발생되어 플랜트 효율이 저하된다. 이러한 문제점을 개선하기 위해 본 논문에서는 터빈제어밸브 모드별 최적의 변압운전 부하 범위를 개선하기 위해 각 부하별 열 성능 분석 방법을 통해 최적의 부하범위를 선정하고자 한다.

무접점 공기압력식 급수시스템 개발 및 최적운전점 결정 (Development of Inverter Controlled Air Pressure Type Water-Supply and Determination of Optimal Operation Pressure)

  • 김정훈;김학봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.181-183
    • /
    • 1994
  • This paper presented the developments and operations of control system for Inverter-controlled air pressure type water-supply systems. The developed controller that enables regular speed and variable speed. In addition, an air supplement control system was developed to establish a utility model of water supply facility system as well as a method to optimize its operation.

  • PDF