• Title/Summary/Keyword: Optimal Pressure Control

Search Result 238, Processing Time 0.024 seconds

A Study on the Optimal Pressure Curve for the Sheet Hydroforming (판재 액압성형 공정에서의 최적압력곡선에 관한 연구)

  • 심현보;양희태;서의권;양동열
    • Transactions of Materials Processing
    • /
    • v.11 no.3
    • /
    • pp.246-254
    • /
    • 2002
  • A simple method to derive an optimal pressure curve, characterized by initial pressure, final pressure and pressure path, has been proposed. The initial pressure has been determined from the condition to prevent recoiling phenomenon in the early stage, while the final pressure is from the FE analysis and pressure path is from the punch penetration volume. In order to realize the pressure curve, an open loop control system based on a proportional relief valve has been developed for the renovated CNC hydroforming press. Through the comparison of experiment and analysis, the predicted pressure curve has been verified optimal curve since no defect has been observed.

A Study on Optimal Pressure Control of Hydraulic Nozzle for Vaccum Foam System of Refrigerator in the 900L Class (900L 냉장고 진공발포시스템 유압노즐의 최적 압력제어에 관한 연구)

  • Jo, Sang-Young;Kim, Min-Seong;Koo, Yeong-Mok;Yang, Jun-Suk;Shin, Haeng-Bong;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.2
    • /
    • pp.50-61
    • /
    • 2016
  • This study proposes a new approach to control the nozzle pressure of homogenizer in refrigerator foam system in the 900L class. Generally, dynamic characteristics of the hydraulic nozzle system is highly nonlinear due to uncertain parameters, and it is very difficult to control of hydraulic dynamics. Firstly, it has been performed to derive a real-time control algorithm based on the mathematical model of hydraulic cylinder, and to estimate the values of the unknown parameter in the hydraulic system. Secondly, the feedback controller was designed to implement the optimal pressure control of the hydraulic nozzle system. Finally the control performance was illustrated by simulation.

A Study on Reduction of Cavitation with Orifice on High Differential Pressure Control Butterfly Valve (오리피스를 이용한 고차압 제어 버터플라이 밸브의 캐비테이션 저감에 관한 연구)

  • Lee, Sang-Beom
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.131-139
    • /
    • 2022
  • The exchange of goods over the sea is a situation in which the amount of trade between countries is gradually increasing. In order to maintain the optimal operating condition, the ship maintains stability and optimal operating conditions by inserting or withdrawing ballast water from the ballast tank according to the loading condition of cargo capacity is also increasing. Control valves play an important role in controlling fluid flow in these pipes. When the flow rate is controlled using a control valve, problems such as cavitation, flashing, and suffocating flow may occur due to high differential pressure, and in particular, damage to valves and pipes due to cavitation is a major problem. Therefore, in this study, the cavitation phenomenon is reduced by installing orifices at the front and rear ends of the high differential pressure control butterfly valve to reduce the sudden pressure drop at the limiting part of the butterfly valve step by step. The flow coefficient according to the shape of the orifice, the degree of cavitation occurrence, and the correlation were analyzed using a CFD(Cumputational Fluid Dynamics), and an optimal orifice design for reducing cavitation is derived.

Controller Development of Booster Multi-Pump System (급수 가압 멀티 펌프 시스템의 컨트롤러 개발)

  • Lee, Sang-Kyun;Lee, Jae-Choon;Lee, Byeong-Hoon;Hwang, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.382-384
    • /
    • 1996
  • This paper introduces the controller development of booster multi-pump system with constantly estimated control algorithm. Through analyzing by the experiment of optimal pressure with a certain flow rate. The larger pressure processing apparatus in microprocessor makes optimal water-supplying. This method is implemented with the only pure control algorithm without any other mechanical or circuitry apparatus. Also, Pump's life is lengthened by exchanging simple on, off and rotational inverter control. Optimal condition for pump is adjusted by the inverter control, and compact control panel helps the booster system install in real field.

  • PDF

Optimal Engine Operation by Shift Speed Improvement for a CVT (CVT 변속속도 개선에 의한 엔진최적운전)

  • Lee, Hee-Ra;Kim, Hyun-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.546-551
    • /
    • 2001
  • In this paper, an algorithm to improve the optimal engine operation is suggested by increasing the CVT shift speed. By rearranging the CVT shift dynamic equation, it is found that the CVT shift speed depends on the line pressure as well as the primary pressure. Based on the shift dynamics, an algorithm to accomplish a faster shift speed is presented by increasing the line pressure. In order to apply the algorithm, dynamic models of the line pressure control valve and the ratio control valve are obtained by considering the CVT shift dynamics and model based controllers are designed. It is found from the simulation results that fuel economy can be improved by 2% in spite of the increased hydraulic loss due to the increased line pressure.

  • PDF

Effect of Optimal Humidification for Extremely Low Birth Weight Infants During Nasal Continuous Positive Airway Pressure (인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향)

  • Kim, Jung-Sook;Lee, Eun-Jung
    • Child Health Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Purpose: To evaluate the efficacy of Optimal humidification during Nasal Continuous Positive Airway Pressure (nCPAP) for Extremely Low Birth Weight Infant (ELBWI). Methods: The study design was a pre-test-post-test nonequivalent nonsynchronized quasi-experimental design. The participants were 218 ELBWI on nCPAP (experimental group: 102 and control group: 116). Data collection was conducted from January 2005 to April 2010. In order to measure and analyze the nCPAP duration, reintubation and nasal condition, Chi-square test and t-test were used. Results: Hypothesis 1, that the duration with nCPAP in the experimental group is longer than that of the control group and hypothesis 2-3, that the rate of reintubation and nasal problems in the experimental group are lower than the control group, were all supported as there were statistically significant differences between two groups. Conclusion: The findings suggest that the Optimal humidification in this study is an efficient intervention because it helps increase the last time of nCPAP with ELBWI and minimize complications. It is expected that Optimal humidification is beneficial and helpful in preventing and caring for respiratory problems in these infants.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

NUMERICAL STUDY ON WIND TUNNEL GROUND PLATE WITH A PRESSURE CONTROL DEVICE (압력 조절 장치를 갖는 풍동 지면판에 관한 수치해석적 연구)

  • Lee, M.J.;Kim, C.W.
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.53-59
    • /
    • 2010
  • Preliminary design of a ground plate, a device installed close to the aircraft model for wind tunnel test to simulate the ground effect, was performed by a numerical simulation. A two-dimensional numerical study was performed initially to decide the optimal leading edge and flap configurations. Then, three-dimensional studies were conducted to decide the optimal flap deflection angle for pressure distribution reduction since the plate and the plate supporting system generate static pressure difference between the upper and lower flow regions. Three-dimensional simulation additionally studied the effect of the clearance between the plate and the wind tunnel side wall. For the efficiency of computation, half model was simulated and a symmetric boundary condition was applied on the center plane. Based on the preliminary design, a ground plate was designed, manufactured and tested at the Korea Aerospace Research Institute(KARI) wind tunnel. The measured pressure differences versus flap deflection angle agreed well with the predicted results.

A Study on the Improvement of Optimal Load Range for Sliding Pressure Operation of coal-fired Power Plant (석탄화력 발전소 최적 변압운전 부하 범위 개선에 대한 연구)

  • Lee, Sang-Hun;Wang, Min-Seok;Wee, Sang-Bong;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.675-680
    • /
    • 2019
  • The coal-fired power plant is operated by a combined operation method, which is operated by sliding pressure operation under low load and by fixed pressure operation under high load for improved efficiency. The combined operation is divided into two and three valve open modes. Each plant is operated by selecting the turbine control valve mode in accordance with the manufacturer's recommendation, but is not really operating at the optimal sliding pressure operation according to load range, also Load range of each plant is configured differently. The internal efficiency of the high-pressure turbines is reduced due to loss of the turbine valves and the plant efficiency is reduced. To solve these problems, In this paper, the optimum load range is selected through the analysis method of thermal performance by each load in order to improve the optimum variable pressure operation load range by turbine control valve mode.

Development of Inverter Controlled Air Pressure Type Water-Supply and Determination of Optimal Operation Pressure (무접점 공기압력식 급수시스템 개발 및 최적운전점 결정)

  • Kim, Jung-Hoon;Kim, Hak-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.181-183
    • /
    • 1994
  • This paper presented the developments and operations of control system for Inverter-controlled air pressure type water-supply systems. The developed controller that enables regular speed and variable speed. In addition, an air supplement control system was developed to establish a utility model of water supply facility system as well as a method to optimize its operation.

  • PDF