• 제목/요약/키워드: Optical therapy

검색결과 129건 처리시간 0.025초

광감제가 코팅된 자성유체의 제조와 광역학 치료용 장치의 구성 (Preparation of Photosensitizer-Coated Ferrofluids and Fabrication of a Device for Photodynamic Therapy)

  • 권순광;김종오;김종희
    • 한국재료학회지
    • /
    • 제12권3호
    • /
    • pp.215-219
    • /
    • 2002
  • For the purpose of annihilating tumor in body, hematoporphyrin as a photosensitizer was coated onto magnetic particles of $Fe_3O_4$ prepared by coprecipitation which could be concentrated around the tumor by magnetic field. The photosensitizer was applied differently before, during and after adsorbing the 1st surfactant on the particles. Its added amount was $5{\times}10^{-4}/mol$, and the coating reaction proceeded at temperatures of 60, 70 and 8$0^{\circ}C$. The amounts of photosensitizer coated on the magnetic particles were obtained by calculating an optical density with the maximum UV spectrum. As a result of the UV analysis, the coating amount of photosensitizer increased with higher reaction temperatures. When applied at 8$0^{\circ}C$ after adsorbing the 1st surfactant, the photosensitizer was coated with a maximum value of $3.8{\times}10^{-3}/mo1/$\ell$$. The TGA analysis revealed that the ferrofluids included the particles of 30.115 g/$\ell$. It was suggested that the magnetite particles was coated with photosensitizer of $1.26{\times}10^{-4}/mo1/g$. A small-sized device for magnetic field and light emission was designed, in which LED sheets coverts the permanent magnet of Nd-Fe-B. The LED sheet was connected in series circuit and also protected with a silicon tube. The power was supplied with rechargable battery of 9V and 100-120mA.

In Vivo Spinal Distribution of Cy5.5 Fluorescent Dye after Injection via the Lateral Ventricle and Cisterna Magna in Rat Model

  • Lee, Kee-Hang;Nam, Hyun;Won, Jeong-Seob;Hwang, Ji-Yoon;Jang, Hye Won;Lee, Sun-Ho;Joo, Kyeung Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권4호
    • /
    • pp.434-440
    • /
    • 2018
  • Objective : The purpose of this study was to find an optimal delivery route for clinical trials of intrathecal cell therapy for spinal cord injury in preclinical stage. Methods : We compared in vivo distribution of Cy5.5 fluorescent dye in the spinal cord region at various time points utilizing in vivo optical imaging techniques, which was injected into the lateral ventricle (LV) or cisterna magna (CM) of rats. Results : Although CM locates nearer to the spinal cord than the LV, significantly higher signal of Cy5.5 was detected in the thoracic and lumbar spinal cord region at all time points tested when Cy5.5 was injected into the LV. In the LV injection Cy5.5 signal in the thoracic and lumbar spinal cord was observed within 12 hours after injection, which was maintained until 72 hours after injection. In contrast, Cy5.5 signal was concentrated at the injection site in the CM injection at all time points. Conclusion : These data suggested that the LV might be suitable for preclinical injection route of therapeutics targeting the spinal cord to test their treatment efficacy and biosafety for spinal cord diseases in small animal models.

반복자기자극이 지방유래 중간엽 줄기세포 증식과 활성에 미치는 영향 (Effect of Repetitive Magnetic Stimulation on Proliferation and Viability of Adipose Tissue-Derived Stromal Cells)

  • 김수정;박해운;조윤우;이준하;서정민;신현진;강재훈;안상호
    • The Journal of Korean Physical Therapy
    • /
    • 제21권3호
    • /
    • pp.87-93
    • /
    • 2009
  • Purpose: TThis study examined the effect of repetitive magnetic stimulation (RMS) on the viability and proliferative response of human adipose tissue-derived stromal cells (hATSCs) in vitro. Methods: The hATSCs were cultured primarily from human adipose tissue harvested by liposuction and incubated in a $37^{\circ}C$ plastic chamber. The cells were exposed to a repetitive magnetic field using a customized magnetic stimulator (Biocon-5000, Mcube Technology). The RMS parameters were set as follows: repetition rate=10Hz, 25Hz (stimulus intensity 100%= 0.1 Tesla, at 4cm from the coil), stimulated time= 1, 5, and 20 minutes. Twenty four hours after one application of RMS, the hATSCs were compared with the sham stimulation, which were kept under the same conditions without the application of RMS. The cells were observed by optical microscopy to determine the morphology and assessed by trypan blue staining for cell proliferation. The apoptosis and viability of the hATSCs were also analyzed by fluorescence-activated cell sorting (FACS) analysis of Annexin V and MTT assay. Results: After RMS, the morphology of the hATSCs was not changed and the apoptosis of hATSCs were not increased compared to the sham stimulation. The viability of the cells was similar to the cells given the sham stimulation. Interestingly, the level of hATSC proliferation was significantly higher in all RMS groups. Conclusion: The application of RMS may not cause a change in morphology and viability of hATSCs but can increase the level of cell proliferation in vitro. RMS might be useful as an adjuvant tool in combination with stem cell therapy without adverse effects.

  • PDF

다양한 특이결핵항원을 이용한 결핵항체 검사(ELISA)의 진단적 유용성 (Diagnostic Significance of the Serologic Test Using Multiple Antigens of Mycobacterium Tuberculosis by ELISA)

  • 김대연;최인환;박승규;조상래;송선대
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권6호
    • /
    • pp.757-767
    • /
    • 1999
  • Background: Diagnosis by smear and/or cultures of the Mycobacterium tuberculosis from body fluid or biopsy specimen is "Gold standard". However the sensitivity of the direct microscopy is relatively low and culture of mycobacteria is time consuming. Despite an explosion in the techniques of rapid identification of mycobacteria by molecular genetic means, it is laborious and expensive and then rapid, inexpensive serodiagnosis is interested in diagnosis of tuberculosis. But sensitivity and specificity of known serologic antigen is not full sufficient level and then new antigen develop and combination cocktails of new developed antigens by ELISA are needed. Method: To compare the efficacy of different mycobacterial specific antigen and to assess the applicability of the combination of several different antigens in the diagnosis of tuberculosis, five ELISA tests derived 14KDa, 16KDa, 19KDa, 23KDa, 38KDa were evaluated in 57 active pulmonary patient and 24 inactive post-therapy follow up patient and 48 normal control. Results: The optical densities of ELISA test with 14KDa, 16KDa, 19KDa, 23KDa, 38KDa were significantly higher in active tuberculosis cases than in normal control(P<0.001, P<0.001, P<0.027, P<0.001, P<0.001) and those with 16KDa, 38KDa were significant higher in active tuberculosis cases than in inactive post-therapy follow up cases(P<0.01. P<0.001) and those of 14KDa, 16KDa, 23KDa, 38KDa were significant higher in inactive post-therapy follow up cases than in normal control(P<0.008. P<0.01. P<0.006. P<0.001). The sensitivity of 14KDa, 16KDa, 19KDa, 23KDa, 38KDa in active pulmonary patient cases was 42.1%, 43.9%, 15.8%, 28.0%, 70.2%, respectively and the specificity of 14KDa, 16KDa, 19KDa, 23KDa, 38KDa in active pulmonary patient cases was 95.8%, 95.8%, 91.7%, 89.6%, 93.8%, respectively. The sensitivity and specificity of combination 38KDa with 16KDa was 87% and 93.7%. Conclusion: The sensitivity and specificity of new antigens for serodiagnosis of the tuberculosis still remains limited at around 70%, which makes its a poor diagnostic tool for disease confirmation. A combination of cocktail antigens provided by cut-off value adjustment for serodiagnosis of tuberculosis some improved diagnostic yield than single antigen serologic test.

  • PDF

Cell-Specific Targeting of Texas Red with Anti-Ep-CAM Antibody

  • Lee, Soo-Chul;Tae, Gun-Sik
    • Journal of Photoscience
    • /
    • 제12권3호
    • /
    • pp.123-127
    • /
    • 2005
  • The polyclonal antibody was generated against the peptide fragment of 62 amino acid residues (D 181-T242) near the COOH-terminal region of the extracellular domain of epithelial-cell adhesion molecule (Ep-CAM) and shown to be able to recognize Ep-CAM in competitive ELISA. Then, sulforhodamine 101 acid chloride (so called Texas red), a fluorescence dye, was conjugated to the affinity-purified anti-Ep-CAM antibody utilizing the reaction between the aliphatic amines of antibody and the sulfonyl chloride of Texas red. The molar ratio of Texas red to antibody was estimated to be approximately 1.86 by measuring optical densities at 280 nm and 596 nm, implying that the two molecules of Texas red at most were conjugated to antibody. The anti-Ep-CAM antibody-Texas red conjugate was then used for immunohistochemistry of CT-26 murine colon carcinoma cells. Based upon the fluorescence microscope images, anti-Ep-CAM antibody is able to deliver Texas red specifically to the surface of CT-26 cells on which Ep-CAM was actively expressed. This result indicates that anti-Ep-CAM antibody could be useful for the tissue-specific delivery of photosensitizers via antigen-antibody interaction.

  • PDF

폐 전이 암에 대한 Lipid Coated Polymeric Nanoparticles에 관한 연구 (Study of Lipid Coated Polymeric Nanoparticles for Lung Metastasis)

  • 박준영;박상효;조예림;정민지;김인우;강원준;기재홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권4호
    • /
    • pp.147-152
    • /
    • 2018
  • Lung cancer and pulmonary metastasis are the leading cause of cancer mortality worldwide. Survival for patients with lung metastases is about 5%. Nanoparticles have been developed for the imaging and treatment of various cancers, including pulmonary malignancies. In this work, we report lipid coated polymeric nanoparticles (LPNs) with an average diameter of 154 nm. In vivo performance of LPNs was characterized using optical imaging system. We expect this nanoparticle can be used for finding lung cancer or lung metastasis. Eventually loading therapeutic drug with the nanoparticle will be utilized for cancer diagnosis and effective therapy at the same time.

복식호흡 훈련과 Self Voice Feedback 프로그램이 성대결절 환자의 음성개선에 미치는 효과 (Effects of Abdominal Respiration and Self Voice Feedback Therapy on the Voice Improvement of Patients with Vocal Nodules)

  • 권순복;왕수건;양병곤;전계록
    • 음성과학
    • /
    • 제13권3호
    • /
    • pp.133-149
    • /
    • 2006
  • This study attempted to compare acoustic parameters, physiological observation and perceptual evaluation values obtained from the treatment and control groups in order to find out which of the self voice feedback therapies was better and which methods to train them were more effective. The experimental group carried out various self voice feedback therapies while the control group did only vocal hygiene. The acoustic measurement and voice manipulation for providing the patients visual, auditory feedback were done by a speech analysis software, Praat. The authors designed vocal hygiene, abdominal respiration and Praat self voice feedback therapies and applied them to 15 patients while applying only one vocal hygiene to 15 of the control group. For the purpose of examining the degree of their voice improvement after the treatment, pre- mid- and final evaluations were made for the two groups at the beginning, the 6th week and immediately after the 8th treatment session. Results of this study were as follows: The treatment group showed much improvement after receiving the voice treatment. In particular, acoustical and physiological indices from the optical endoscopy, pitch variation(Jitter), amplitude variation (Shimmer), maximum phonation time(MPT), and psychoacoustic evaluation showed statistically significant improvements over the control groups.

  • PDF

아두이노 기반 암세포 증식억제 모듈의 효과에 대한 기초연구 (Basic study on proliferation control of cancer cells using Arduino based therapeutic module)

  • 조경래;박기태;김민수;최세운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.470-472
    • /
    • 2017
  • 현재 항암치료는 외과적 수술, 방사선 또는 광학을 이용한 치료법, 그리고 약물을 이용한 치료법 등을 활용한 다양연구가 진행되고 있다. 또한 고가의 항암 치료제와 대형화된 장비가 개발되어 정확도 및 치료효과를 높이고 있으나, 광원의 종류, 방사선, 항암치료제 등의 오남용에 기인한 많은 부작용이 초래되었다. 따라서 본 논문에서는, 상대적으로 저렴하고 조작이 간편하며, 다양한 파장대 광원의 사용이 가능한 마이크로컨트롤러 기반 맞춤형 암세포 증식 억제 키트를 개발하여 그 효과를 보임으로써 새로운 항암치료법을 제시하고자 한다.

  • PDF

Research of 3D image processing of VR technology in medicine based on DNN

  • ZhaoZhe, Gong;XiaoDong, Li;XiaoYing, Shi;Geng, Liu;Bin, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권5호
    • /
    • pp.1584-1596
    • /
    • 2022
  • According to a survey published in an authoritative journal in January 2020, the globalincidence rate of mental illness is 8.3% for men and 10.6% for women, which indicates thatmental illness has become a globally recognized obstacle. Therefore, specific psychotherapy including mental illness will become an important research topic. It is very effective forpatients with special mental diseases, such as mental illness, to reduce their mental reaction byexposure therapy; the system uses the virtual reality system of medical images processed by learningalgorithm to reproduce the effect of virtual reality exposure method of the high scene of transparent ladder. Compared with the old invasive exposure scene, the results show that theimprovement of both conditions has obvious effect, and the effect of human treatment underthe two conditions is not good. There are obvious differences, which show that virtual reality model will gradually replace the on-the-spot feeling. Finally, with more and more researchers have put forward a variety of other virtual reality image processing models, the research of image processing has gradually become more and more interested.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.