• Title/Summary/Keyword: Optical Resolution

Search Result 1,472, Processing Time 0.03 seconds

Pulse-Pre Pump Brillouin Optical Time Domain Analysis-based method monitoring structural multi-direction strain

  • Su, Huaizhi;Yang, Meng;Wen, Zhiping
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.2
    • /
    • pp.145-155
    • /
    • 2016
  • The Pulse-Pre Pump Brillouin Optical Time Domain Analysis (PPP-BOTDA) technique is introduced to implement the multi-direction strain measurement. The monitoring principle is stated. The layout scheme of optical fibers is proposed. The temperature compensation formula and its realizing method are given. The experiments, under tensile load, combined bending and tensile load, are implemented to validate the feasibility of the proposed method. It is shown that the PPP-BOTDA technique can be used to discriminate the multi-direction strains with high spatial resolution and precision.

Optical fiber Y-Branch Fabrication and OTDR application (Optical Fiber Y-Branch의 제작과 OTDR 응용)

  • Lee, Sang-Ho;Gang, Min-Ho;Park, Han-Gyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.3
    • /
    • pp.21-24
    • /
    • 1981
  • A simple optial fiber Y-branch is fabricated using micro - torch and fusion splicer. Tapered end of two fibers - in -contact is spliced with another fiber. Total insertion loss is 26dB and optical power branchi ng ratio is 0.98. Using fiber Y-branch, an UTDR with simple optical system is realized The resolution of the OTDR is $\pm$ 5m in length and t 0.5 dB/km in loss coefficient.

  • PDF

Fabrication of Near-field Scanning Optical Microscope(NSOM) Probe by Chemical Etching (화학적 식각을 이용한 근접장 주사 현미경용 탐침의 제작)

  • Kim, Sung-Chul;Lee, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.555-557
    • /
    • 1995
  • In near field optics, optical fiber probe is smaller than the wavelength of light. This small probe makes it possible to overcome the diffraction limit due to wave property of light. In conventional optical systems, the image resolution is governed by wavelength. But in NSOM, it is determined by probe tip size and probe shape. Therefore probe tip size and shape are very important points in near field optics. In this paper, we will suggest the new fabrication methods of optical fiber probe and show that the probe tip size is sub-micrometer using SEM.

  • PDF

An Algorithm for the Characterization of Surface Crack by Use of Dipole Model and Magneto-Optical Non-Destructive Inspection System

  • Lee, Jin-Yi;Lyu, Sung-Ki;Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1072-1080
    • /
    • 2000
  • Leakage magnetic flux (LMF) is widely used for non-contact detection of cracks. The combination of optics and LMF offers advantages such as real time inspection, elimination of electrical noise, high spatial resolution, etc. This paper describes a new nondestructive evaluation method based on an original magneto-optical inspection system, which uses a magneto-optical sensor, LMF, and an improved magnetization method. The improved magnetization method has the following characteristics: high observation sensitivity, independence of the crack orientation, and precise transcription of the geometry of a complex crack. The use of vertical magnetization enables the visualization of the length and width of a crack. The inspection system provides the images of the crack, and shows a possibility for the computation of its depth.

  • PDF

Measurements of Evanescent Wave using a Mano-size Optical Probe (나노 사이즈 광프로브에 의한 에버네슨트파의 측정)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.

Precision Displacement Measurement Using Astigmatism (비점수차법을 이용한 초정밀변위측정법 연구)

  • Lee, Sang-Heon;Jung, Kwang-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.87-94
    • /
    • 2008
  • The displacement sensor using optical pickup head is presented. The measuring principle of optical pickup head in focusing direction is adopted to measure displacement. The preliminary tests were carried out to verify the feasibility of the optical pickup head as a displacement sensor and optical pickup head showed about $8\;{\mu}m$ measuring range and 10nm resolution. The methodology to expand measuring range is proposed and proved its validity. The proposed displacement sensors are applied to AFM(Atomic Force Microscope) probe head to measure the deflection of micro-cantilever.

Murine Heart Wall Imaging with Optical Coherence Tomography

  • Kim Jee-Hyun;Lee Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • M-mode imaging of the in vivo murine myocardium using optical coherence tomography (OCT) is described. Application of conventional techniques (e.g. MRI, Ultrasound imaging) for imaging the murine myocardium is problematic because the wall thickness is less than 1.5 mm (20 g mouse), and the heart rate can be as high as six hundred beats per minute. To acquire a real-time image of the murine myocardium, OCT can provide sufficient spatial resolution ($10{\mu}m$) and imaging speed (1000 A-scans/s). Strong light scattering by blood in the heart causes significant light attenuation, which makes delineation of the endocardium-chamber boundary problematic. To measure the thickness change of the myocardium during one heart beat cycle, a myocardium edge detection algorithm is developed and demonstrated.

A Study on the Mechanism of Rotational Stage with Multi Degree of Freedom for Multi-Channel Optical Alignment System (다채널 광정렬 장치에서의 다자유도 회전 스테이지 동작 특성에 관한 연구)

  • Jeong Sanghwa;Cha Kyoungrae;Kim Hyunuk;Choi Sukbong;Kim Kwangho;Park Junho
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.150-155
    • /
    • 2005
  • In recent years, as the demands of VBNS(Very high speed Backbone Network Service) and VDSL(Very high-data rate Digital Subscriber Line) increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, WDM elements increase. The alignment and the attachment technology are very important to fabricate the optical elements for communication. In this paper, the mechanism of rotational stage are studied. with the three different method and the results of them are applied to the design of the system. The performance test of resolution and travel is performed.

  • PDF

Fabrication and Performances Tests of the Optical Fiber Position Sensor for Application to Spindle State Monitoring (주축 상태 모니터링 용 광파이버 변위센서 제작 및 성능평가)

  • Shin Woo-cheol;Hong Jun-hee;Park Chan-gyu
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.37-44
    • /
    • 2005
  • This paper presents fabrication techniques of the optical fiber position sensor (or spindle state monitoring. These include selection of components such as optical fibers, a laser-diode, a photo-diode, and op-amp IC of the signal process circuit. We also describe electric runout problem. The fabricated sensor has a linearity of $1.7\%$ FSO in the air gap range $0.1\~0.6mm$, a resolution of $0.37{\mu}m$ and a bandwidth of 6.3kHz. Finally, we have successfully operated a magnetic bearing spindle system using the sensors.

A Combined Atmospheric Radiative Transfer Model (CART): A Review and Applications

  • Chen, Xiuhong;Wei, Heli
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.190-198
    • /
    • 2010
  • A set of radiative transfer software named CART (Combined Atmospheric Radiative Transfer) has been developed to rapidly calculate atmospheric transmittance and background radiance. The spectral resolution of CART is $1cm^{-1}$, and the spectral region covers from 1 to $25000cm^{-1}$. CART has five characteristic features, and it can be applied to many fields. The features and applications of CART are summarized in detail.