• Title/Summary/Keyword: Optical Interferometer

Search Result 615, Processing Time 0.029 seconds

Enhancement of IPDR of SOA-MZI Wavelength Converter with Pre-amplifier Using a CW-HB (CW-HB를 이용하는 전치증폭기를 가진 SOA-MZI 파장변환기에서 IPDR 개선)

  • Kim Joo-Youp;Han Sang-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1A
    • /
    • pp.11-15
    • /
    • 2006
  • A pre-amplified semiconductor optical amplifier-Mach-Zehnder interferometer(SOA-MZI) wavelength converter (WC) using a continuous wave-holding beam(CW-HB) is proposed and experimentally demonstrated at 10Gb/s. The proposed scheme achieves not only enhancement of input power dynamic range(IPDR) to over 20dB but also higher Q parameter of about 2 to 3 by no output signal distortion and higher extinction ratio(ER) of about 2dB to 5dB by low noise figure (NF), compared with the bias current control method.

The measurement of the internal strain of a concrete specimen using optical fiber interferometric sensors (광섬유 간섭계 센서를 이용한 콘크리트 구조물의 내부 스트레인 측정)

  • Lee, Kyung-Jin;Park, Jae-Hee;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.304-309
    • /
    • 2001
  • A Fiber optic strain sensor for the measurement of the internal strain of a concrete specimen was developed. This sensor was a 11 mm Fiber-optic Fabry-Perot interferometer attached inside a stainless steel pipe of 2 mm diameter. The fabricated strain sensors were embedded in a reinforced concrete structure of $100{\times}100{\times}500\;mm^3$ size and were measured the internal strain of a concrete structure when the external pressure was applied to the structure. For a field application, the strain sensors were attached on the bottom of a real bridge and dynamic loading test were executed. In the test, they showed good sensitivity as a deformation sensor and capability of remote monitoring.

  • PDF

Dynamic Response Measurement of the Head Arm Assembly of a Hard Disk Drive by Numerical Analysis and Experiments

  • Parlapalli, Madhusudhana R;Bin, Gu;Dongwei, Shu;Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.22-25
    • /
    • 2008
  • The dynamic response of the head arm assembly (HAA) of a hard disk drive to an impact load was obtained from a 3D non-linear finite element model using ANSYS/LS-DYNA and from experiments using a modified levitation mass method (LMM). In the finite element model, the impact load was created by modeling the mass as a rigid body and making it collide with the HAA. The velocity, displacement, acceleration, and inertial force of the mass were then obtained from the time history data of the finite element analysis. In the LMM, a mass that was levitated with an aerostatic linear bearing, and hence encountered negligible friction, was made to collide with the actuator arm, resulting in a dynamic bending test for the arm. During the collision, the Doppler frequency shift of the laser beam reflected from the mass was accurately measured with an optical interferometer. The velocity, displacement, acceleration, and inertial force of the mass were accurately calculated from the measured time-varying Doppler frequency shift. A good correlation between the experimental data and FEA results was observed. The FEA was also used to investigate the dynamic response of the HAA to impact by different masses.

Eye Pattern Characteristic Based Active Stabilization Method for Direct Delection Receiver in Differential Phase Shift Key System (차동 위상 변조 전송 시스템에서 수신 신호 눈열림 특성을 이용한 직접 검출 수신단 최적화 및 안정화 제어 연구)

  • Jang, Youn-Seon;Park, Heuk;Kim, Kwang-Joon
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.313-318
    • /
    • 2005
  • We propose an active stabilization method for the receiver of NRZ-DPSK transmission. The 1-bit delayed Mach-Zehlder interferometer is thermally controlled to maintain the largest DC component power ratio between the constructive and destructive output ports, for the optimum transmission condition. This method is very cost effective since no additional components are required. Experimental results show that the proposed scheme guarantees error free performance even when there was ~ 1 GHz optical carrier frequency fluctuation in 10 Gbps transmission.

Simultaneous Measurements of Local Phase and Reflectivity Variation of a Surface Using Multiport Homodyne Interferometer (다출력단 호모다인 간섭계를 이용한 위상 및 반사율 분포의 동시 측정)

  • 정희성;김종회;조규만
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.60-61
    • /
    • 2000
  • 표면 형상을 측정하는 방법은 샘플표면의 평평도, 곡률, 거칠기, 깊이 측정등의 수많은 상업적 응용을 위해 광범위하게 개발되어왔다. 이중에서도 특히 간섭현상을 이용한 광 표면 프로파일러는 표면의 3차원 구조를 측정하는데 있어서 subangstrom의 매우 높은 깊이 분해능을 가지므로 샘플 표면의 정밀 진단에 많이 사용되어 왔다. [1,2] 광 간섭 현미경은 기본적으로 광위상 변화를 검출하여 그것을 표면구조변화로 바꾸어주는 역할을 한다. 그러나 광위상 변화는 샘플 표면의 구조뿐만 아니라 물질 변화와 박막두께 변화에도 민감하므로 순수한 표면구조측정은 샘플이 단일물질인 경우에만 달성된다는 문제점이 있다. 따라서 이러한 광위상 측정과 관련된 ambiguity를 해결하기 위해서는 일반적인 광 간섭 현미경에서 얻어지는 위상데이터와 더불어 물질변화를 분석할 수 있는 다른 추가적인 데이터가 필요하다. 이러한 필요성 때문에 우리는 광위상 뿐만 아니라 반사율 분포도 동시에 측정할 수 있는 새로운 방식의 다출력단 호모다인 간섭계(Homodyne I/Q Interferometer; HIQI)를 구성하였으며[3], 그 실험장치도는 [Fig. 1]과 같다. HIQI는 in-phase and quadrature 검출방식에 기반을 두며, 이 검출방식은 PBS에서 반사되는 빛살과 투과되는 빛살 사이의 위상차가 $\pi$/4라는 실험결과로부터 달성된다. HIQI는 샘플 표면의 3차원 구조 뿐만 아니라 광학적 특성의 2차원 분포도 동시에 얻을 수 있다. (중략)

  • PDF

A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device (자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구)

  • 이정화;류제길;박기환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

Spectral Reconstruction for High Spectral Resolution in a Static Modulated Fourier-transform Spectrometer

  • Cho, Ju Yong;Lee, Seunghoon;Kim, Hyoungjin;Jang, Won Kweon
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.244-251
    • /
    • 2022
  • We introduce a spectral reconstruction method to enhance the spectral resolution in a static modulated Fourier-transform spectrometer. The optical-path difference and the interferogram in the focal plane, as well as the relationship of the interferogram and the spectrum, are discussed. Additionally, for better spectral reconstruction, applications of phase-error correction and apodization are considered. As a result, the transfer function of the spectrometer is calculated, and then the spectrum is reconstructed based on the relationship between the transfer function and the interferogram. The spectrometer comprises a modified Sagnac interferometer. The spectral reconstruction is conducted with a source with central wave number of 6,451 cm-1 and spectral width of 337 cm-1. In a conventional Fourier-transform method the best spectral resolution is 27 cm-1, but by means of the spectral reconstruction method the spectral resolution improved to 8.7 cm-1, without changing the interferometric structure. Compared to a conventional Fourier-transform method, the spectral width in the reconstructed spectrum is narrower by 20 cm-1, and closer to the reference spectrum. The proposed method allows high performance for static modulated Fourier-transform spectrometers.

Experimental Investigation of a High-repetition-rate Pr3+:YLF Laser with Single-frequency Oscillation

  • Dai, Weicheng;Jin, Long;Dong, Yuan;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.721-729
    • /
    • 2021
  • We demonstrate a Pr3+:YLF 639.7-nm laser with single-frequency output based on the Q-switched pre-lase technology, pumped by a fiber-coupled GaN blue laser diode. The pre-lase technology is realized by the step-type loss of the acousto-optical Q-switched device. The conclusions of the theoretical research are verified experimentally. The mode-suppression ratio was 44 dB at the single-frequency laser output. Detection by interferometer verified the realization of the stable single-frequency laser. In addition, the emission spectrum had a linewidth of 139.9 MHz, measured by Fabry-Perot interferometer. The single-frequency laser's single-peak power was over 19.7 W with 98.8-ns pulse duration, obtained under an absorption power of 1.74 W.

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.