• Title/Summary/Keyword: Optical Amplification

Search Result 150, Processing Time 0.032 seconds

Lanthanide-Cored Supramolecular Systems with Highly Efficient Light-Harvesting Dendritic Arrays towards Tomorrow′s Information Technology

  • Kim, Hwan-Kyu;Roh, Soo-Gyun;Hong, Kyong-Soo;Ka, Jae-Won;Baek, Nam-Seob;Oh, Jae-Buem;Nah, Min-Kook;Cha, Yun-Hui;Jin Ko
    • Macromolecular Research
    • /
    • v.11 no.3
    • /
    • pp.133-145
    • /
    • 2003
  • We have developed novel lanthanide-cored supramolecular systems with highly efficient light-harvesting dendritic arrays for integrated planar waveguide-typed amplifiers. Er$^{3+}$ ions were encapsulated by the supramolecular ligands, such as porphyrins and macrobicyclics. The supramolecular ligands have been designed and synthesized to provide enough coordination sites for the formation of stable Er(III)-chelated complexes. For getting a higher optical amplification gain, also, the energy levels of the supramolecular ligands were tailored to maintain the effective energy transfer process from supramolecular ligands to erbium(III) ions. Furthermore, to maximize the light-harvesting effect, new aryl ether-functionalized dendrons as photon antennas have been incorporated into lanthanide-cored supramolecular systems. In this paper, molecular design, synthesis and luminescent properties of novel lanthanide-cored integrated supramolecular systems with highly efficient light-harvesting dendritic arrays will be discussed.d.

Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

Fluorescence Immunoassy of HDL and LDL Using Protein A LB Film

  • Choi, Jeong-Woo;Park, Jun-Hyo;Lee, Woo-Chang;Oh, Byung-Keun;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.979-985
    • /
    • 2001
  • A fluorometric detection technique for HDL (High Density Lipoprotein) and LDL (Low Density Lipoprotein) was developed for application in a fiber-optic immunosensor using a protein A Langmuir-Blodgget (LB) film. For the fluorescence immunoassay, antibodies specific to HDL or LDL were imobilied on the protein A LB film, and a fluorescence amplification method was developed to overcome their weak fluorescence. The deposition of protein A using the LB technique was monitored using a surface pressure-are $({\pi}-A)$ curve, and the antibody immobilization of the protein A LB film was experimentally verified. The immobilized antibody was used to separate only HDL and LDL from a sample, then the fluorescence of he separated HDL or LDL was amplified. The amount of LDL or HDL was measured using the developed fiber optic fluorescence detection system. The optical properties resulting from the reaction of HDL or LDL with o-phtaldialdehyde, detection range, response time, and stability of the immunoassay were all investigated. The respective detection ranges for HDL and LDL were sufficient to diagnose the risk of coronary heart disease. The amplification step increased the sensitivity, while selective separation using the immobilized antibody led to linearity in the sensor signal. The regeneration of the antibody-immobilized substrate could produce a stable and reproducible immunosensor.

  • PDF

Three-staged amplifier properties of single-short pulsed distributed feedback dye laser using a XeCl laser (XeCl 레이저를 이용한 단일 단펄스 분포궤한 색소레이저의 3단 증폭기 특성)

  • 김성훈;이영우;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.424-429
    • /
    • 1999
  • The amplifier properties of single distributed feedback dye laser with 106 ps pulse width and 616 nm wavelength were invested using only one XeCl-excimer laser as pump source. For optimized amplification of DFDL, the three-stage amplifiers were arranged with increasing cross-section and accordingly increasing pump energies. The first AmpI, II stages were dye cell of 5 mm, 10 mm and contained a $6{\times}10^{-4}$ [mol/l](solvent : Methanol) of Rhodamine 610. Double-pass amplification in the AmPII was measured to suppress the ASE by using a diffraction grating. The beam intensity of AmpI, II was saturated with a gain of respectively 10 and 48. The last AmpIII was Bethune cell of 30 mm and contained a $3{\times}10^ {-4}$ [mol/l] (solvent : Ethanol) of Rhodamine 610. In the single-pass and double-pass amplification, the output energy was obtained 168.2 $\mu$J and 471$\mu$J respectively.

  • PDF

Self Displacement Sensing (SDS) Nano Stage

  • Choi, Soo-Chang;Park, Jeong-Woo;Kim, Yong-Woo;Lee, Deug-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.70-74
    • /
    • 2007
  • This paper describes the development of a nano-positioning system for nanoscale science and engineering. Conventional positioning systems, which can be expensive and complicated, require the use of laser interferometers or capacitive transducers to measure nanoscale displacements of the stage. In this study, a new self-displacement sensing (SDS) nano-stage was developed using mechanical magnification of its displacement signal. The SDS nano-stage measured the displacement of its movement using a position-sensitive photodiode (PSPD), a laser source, and a hinge-connected rotating mirror plate. A beam from a laser diode was focused onto the middle of the plate with the rotating mirror. The position variation of the reflected beam from the mirror rotation was then monitored by the PSPD. Finally, the PSPD measured the amplified displacement as opposed to the actual movement of the stage via an optical lever mechanism, providing the ability to more precisely control the nanoscale stage. The displacement amplification process was modeled by structural analysis. The simulation results of the amplification ratio showed that the distance variation between the PSPD and the mirror plate as well as the length L of the mirror plate could be used as the basic design parameters for a SDS nano-stage. The PSPD was originally designed for a total travel range of 30 to 60 mm, and the SDS nano-stage amplified that range by a factor of 15 to 25. Based on these results, a SDS nano-stage was fabricated using principle of displacement amplification.

Dispersion Map Optimization and Dispersion Slope Mismatch Issue on 40 Channel x 10 Gbit/s Transmission Over 3000 km Using Standard SMF and all EDFA Amplification (표준 단일모드 광섬유와 EDFA를 이용한 10 Gb/s 40 파장다중 채널 신호의 3000 km 전송에서 분산 보상 맵 최적화와 분산 기울기 불일치 영향)

  • Kim Min-Sung;Choi Bo-Hun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1A
    • /
    • pp.1-9
    • /
    • 2005
  • We have studied the dispersion properties of a 40 channel x 10 Gbit/s wavelength division multiplexer(WDM) transmission link using standard single mode fiber with all EDFA amplification over 30 x 100 km spans. The dispersion map of the link was investigated by adding fiber sections with positive or negative dispersion at the transmitter, within each amplifier span, and at the receiver. Optimum combinations of these dispersive fiber lengths were attained to significantly enhance the overall transmission performance.

X-ray laser development using laser-produced plasmas (레이저-플라즈마를 이용한 X-선 레이저의 연구)

  • 남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.67-72
    • /
    • 1992
  • Since the inception of the idea to develop an X-ray laser in 1960's, a rapid progress to demonstrate soft X-ray lasers in the wavelength region below 300$\AA$ has been made during the last ten years. Among many prospective proposals, the recombination scheme and the collisional exitation scheme have been most successful in achieving a significant gain. An appreciable single-pass amplification was achieved at 182 $\AA$ from CVI ions using the recombination scheme and at 206 and 290$\AA$ from the Se XXV ions using the collisional excitation scheme. The current research on X-ray lasers emphasizes the enhancement of amplification upto saturation and the extension of operating wavelength to shorter wavelengths, especially to the water window region between 23 and 44 $\AA$. X-ray lasers are expected to open many application fields, such as X-ray laser microscopy, X-ray holography, X-ray lithography, and more, in the near future.

  • PDF

Noise and Timing Jitter Consideration in Microwave Photonic Systems (마이크로웨이브 포토닉 시스템에서의 잡음과 지터에 관한 연구)

  • Jung, Byung-Min;Lee, Seung-Hun;Chang, YuShin
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.234-242
    • /
    • 2021
  • In case implementation of microwave photonic (MWP) systems for phased array radars (PARs), noise and time delay error should be minimized to obtain accurate beam direction. Time delay error in MWP systems is generated from signal noise and timing jitter. In this paper, noise and timing jitter in MWP systems for PAR is researched, also according to the amplification of an erbium-doped fiber amplifier, noise and timing jitter variation is verified by an experiment. Timing jitter is decreased and SNR is increased if we amplify the signal by using an erbium-doped fiber amplifier, up to the amplification rate of signal and noise is similar.

Cascaded Raman fiber amplifier operating at 1.3.mu.m using WDM couplers

  • Chang, Do-Il;Kong, Hong-Jin;Chernikov, S.V.;Guy, M.-J.;Taylor, J. R.
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.110-115
    • /
    • 1997
  • We report effcient cascaded Raman generation and signal amplification at 1.3.mu.m achieved in a ring resonator constructed solely from fiber components, i.e. fusion WDM couplers. Low-loss single-mode fiber with moderate $GeO_2$ content (18 mole %) is used as an active medium and pumped by a Nd:YAG laser at 1.064.mu.m. In a resonant cascaded geometry, this generates the third Stokes line at 1.24.mu.m, which acts as a pump for signal wavelength around 1.3.mu.m. A DFB laser operating at 1.315.mu.m is used to provide an input signal. An output signal powers up to 20 dBm (100 mW) with a 28 dB Raman gain are attained, where the Nd:YAG pump power is 3.4 W. It is also shown experimentally that it is important to use optical filters to suppress feedback from the resonator, permitting high Raman gain and good signal quality.

LCD Embedded Hybrid Touch Screen Panel Based on a-Si:H TFT

  • You, Bong-Hyun;Lee, Byoung-Jun;Lee, Jae-Hoon;Koh, Jai-Hyun;Takahashi, Seiki;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.964-967
    • /
    • 2009
  • A new hybrid-type touch screen panel (TSP) has been developed based on a-Si:H TFT which can detect the change of both $C_{LC}$ and photo-current. This TSP can detect the difference of $C_{LC}$ between touch and no-touch states in unfavorable conditions such as dark ambient light and shadows. The hybrid TSP sensor consists of a detection area which includes one TFT for photo sensing and two TFTs for amplification. Compared to a single internal capacitive TSP or an optical sensing TSP, this new proposed hybrid-type TSP enables larger sensing margin due to embedding of both optical and capacitive sensors.

  • PDF