• Title/Summary/Keyword: Optic lens

Search Result 100, Processing Time 0.025 seconds

Design and Fabrication of APD-FET Module for 2.5 Gbps Optical Communicating System (광통신용 APD-FET 광수신모듈 설계 및 제작)

  • 강승구;송민규;윤형진;박경현;박찬용;박형무;윤태열;이창희;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.166-172
    • /
    • 1994
  • The fiber optic receiver, ETRI APD-FET 1.0, is developed for the application of optical communication. This fiber optic receiver includes PD sub-module and pre-amplifier case. A single lens system is introduced for the PD sub-module. The sub-module consists of the avalenche photodiode(APD), GRIN rod lens, and a single mode fiber. The above components are enclosed into the stainless steel 304L housings. By bevelling the fiber end, the single mode fiber provides less than ~ 28 dB of optical return loss. The area of image focus is controlled by adjusting the length of spacer located in-between the fiber and the GRIN rod lens. The laser welding technique is applied to achieve the maximum coupling efficiency for the joining of each housing. In the pre-amplifier case, GaAs FET pre-amplifier workes for photocurrent amplification and the thermister is mounted to control the APD bias. The performance of ETRI APD-FET1.0 shows the sensitivity of - 30.3 dBm at $10^{-10}$ BER(bit error rate) and 2.5 Gbps optical random signal of $2^{23}-1$ word length. The fiber optic receiver is one of the essensial parts of the transmission module for B-ISDN. Also, the above optical packaging technology will be adapted for the developement of 10 Gbps transmission application 2.5 Gbps 5 Gbps

  • PDF

Development of Intelligent Remote Beam Control Function in E-Beam Manufacturing System (전자빔 가공기의 지능형 원격 빔 조절 기능의 개발)

  • Lim Sun-Jong;Lyou Joon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.24-29
    • /
    • 2006
  • The use electron-beam(E-beam) manufacturing system provides a means to alleviate optic exposure equipment's problems. We are developing an E-beam manufacturing system with scanning electron microscope(SEM) function. The E-beam manufacturing system consist of high voltage generator, beam blanker, condenser lenses, object lenses, stigmator and stage. The development of E-beam manufacturing system is used on the method of remaking SEM's structure. The functions of SEM are developed. It is important for the test of E-beam performance. In E-beam manufacturing system and SEM, beam focus is important function. In this paper, we propose intelligent remote control function for beam focus in E-beam manufacturing system. The function extends the user's function and gives convenience.

Morphogenesis of the Eye of Brown Croaker (Miichthys miiuy)

  • Park, In-Seok;Seol, Dong-Won;Cho, Sung-Hwoan;Song, Young-Chae;Choi, Hee-Jung;Noh, Choong-Hwan;Myoung, Jung-Goo;Kim, Jong-Man
    • Ocean and Polar Research
    • /
    • v.28 no.3
    • /
    • pp.287-290
    • /
    • 2006
  • Eye growth and lens diameter of brown croaker Miichthys miiuy were positively allometric between hatching and 180 days post-hatch (d.p.h.). Eye growth in relation to head length and head height was nearly isometric. Eyes were formed completely at 14 d.p.h. At this age, the eye has a crystalline lens, an optic nerve fiber layer, a ganglion cell layer, an inner plexiform layer, an inner nuclear layer, an outer plexiform layer, an outer nuclear layer, an outer limiting membrane, and a pigment epithelium. The essential demands that must be met by the retina in this species pertain to light sensitivity and spatial resolution.

Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator (광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

Protective Effects of Verapamil against H2O2-Induced Apoptosis in Human Lens Epithelial Cells

  • Wang, Zhuo;Wang, Dan;Li, Yan;Zhang, Xiuli
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.553-557
    • /
    • 2014
  • Verapamil is used in the treatment of hypertension, angina pectoris, and atrial fibrillation. Recently, several studies have demonstrated that verapamil increased the optic nerve head blood flow and improved the retrobulbar circulation. All these show that verapamil is potentially useful for ophthalmic treatment. Thus, the aim of this study is to investigate whether verapamil could protect human lens epithelial cell (HLEC) from oxidative stress induced by $H_2O_2$ and the cellular mechanism underlying this protective function. The viability of HLEC was determined by the MTT assay and apoptotic cell death was analyzed by Hoechst 33258 staining. Moreover, Caspase-3 expression was detected by immunocytochemistry and flow cytometry analysis. We also detected Caspase-3 mRNA expression by reverse-transcription-polymerase chain reaction and the GSH content in cell culture. The results showed that oxidative stress produced significant cell apoptotic death and it was reduced by previous treatment with the verapamil. Verapamil was effective in reducing HLEC death mainly through reducing the expression level of apoptosis-related proteins, caspase-3, and increasing glutathione content. Therefore, it was suggested that verapamil was effective in reducing HLEC apoptosis induced by $H_2O_2$.

Correction method for the Variation of the Image Plane Generated by Various Symmetric Error Factors of Zoom Lenses of Digital Still Cameras and Estimation of Defect Rate Due to the Correction (디지털 카메라용 줌렌즈에서 대칭성 오차요인에 의한 상면 변화의 보정과 이에 따른 불량률 예측)

  • Ryu, Jae-Myung;Kang, Geon-Mo;Lee, Hae-Jin;Lee, Hyuck-Ki;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.420-429
    • /
    • 2006
  • In the zoom lens of digital still cameras with the variation of the image plane generated by various symmetric error factors such as curvature, thickness and refractive index error of each lens surface about the optic axis, we induce a theoretical condition to fix constantly the image plane by translating the compensator group of the zoom lens by using the Gaussian bracket. We confirm the validity of this condition by using three examples of general zoom lens types with 3, 4, and 5 groups, respectively. When these error factors are randomly changed within the range of tolerance according to the Monte Carlo method, we verify that the distributions of the degree of moving of the compensator are normal distributions at three zoom lens types. From capability analysis using these results, we theoretically propose the method estimating the standard deviation, that is, sigma-level, as a function of the maximum movement of the compensator.

A Study on the Productivity Improvement of Thermal Infrared Camera an Optical Lens (열적외선 카메라용 광학계 생산성 향상에 관한 연구)

  • Kim, Sung-Yong;Hyun, Dong-Hun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.285-293
    • /
    • 2009
  • Thermal infrared cameras have been conducted actively in various application areas, such as military, medical service, industries and cars. Because of their characteristic of sensing the radiant heat emitted from subjects in the range of long-wavelength($3{\sim}5{\mu}m$ or $8{\sim}12{\mu}m$), and of materializing a vision system, when general optics materials are used, they don't react to the light in the range of long-wavelength, and can't display their optic functions. Therefore, the materials with the feature of higher refractive index, reacting to the range of long-wavelength, are to be used. The kinds of materials with the characteristic of higher refractive index are limited, and their features are close to those of metals. Because of these metallic features, the existing producing method of optical systems were direct manufacturing method using grinding method or CAD/CAM, which put limit on productivity and made it difficult to properly cope with the increasing demand of markets. GASIR, a material, which can be molded easily, was selected among infrared ray optics materials in this study, and the optical system was designed with two Aspheric lenses. Because the lenses are molded in the environment of high temperature and high pressure, they require a special metallic pattern. The metallic pattern was produced with materials with ultra hardness that can stand high temperature and high pressure. As for the lens mold, GMP(Glass Molding Press) of the linear transfer method was used in order to improve the productivity of optical systems for thermal infrared cameras, which was the goal of this paper.

  • PDF

Measurement dose of Dental Panoramagraphy using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 파노라마 검사의 피폭선량 측정)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2624-2628
    • /
    • 2011
  • Exposed dose of a patient was measured by Radiophotoluminescent Glass Rod Detector with a use of a panorama graphic device in dental examination. The effect of exposed dose in optic lens was measured by comparing the different materials of the glasses. Depending on the dental location, the exposed dose distribution was 82.4~2,340uSv. It showed that the maximum difference in dose distribution was over 300%. Thus, when manufacturing the devices, it seemed to require shortening the pre-heat time and additional shielding in order to control the diagnosis and exposed dose. The measurement data of the exposed dose in optic lens was increased 20~75uSv per each test when compared putting on glasses with not wearing. As a result, taking off the glasses is recommended to improve efficiency of the test and minimize the exposed dose during dental panorama graphic examinations.

Evaluation of optical properties for the development of high resolution ophthalmic endoscope (고 분해능 안구내시경 개발을 위한 광학적 특성 평가)

  • Lee Bongsoo;Cho Dong Hyun;Kim Sin;Cho Hyosung
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.429-434
    • /
    • 2004
  • An ophthalmic endoscope which is used in medical applications should have the total diameter less than 1 mm. Its image resolution is limited to 30∼40 lp/mm. Therefore, the image resolution is one of the most important factors to decide image quality of the ophthalmic endoscopic images. This study obtained high resolution and magnifying ophthalmic endoscopic images by a new optical design using a 0.23 pitch GRIN lens and high resolution fiber-optic image guide which has less than 5 ${\mu}{\textrm}{m}$ diameter microfibers. The resolutions of images from existing and from a new type of ophthalmic endoscope are measured and compared using a USAF resolution target.

The characteristics and optimal modeling of input source for optical device using thin film filter in optical telecommunication network (광통신용 박막필터형 광소자 분석을 위한 최적화 모델링과 특성분석)

  • 김명진;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.306-311
    • /
    • 2003
  • In this paper, we modeled the incident beam in order to analyze and evaluate the optical thin film device for wavelength division multiplexing in optical telecommunication network. As applied ray tracing method to the optical path, we were compared the accuracy of coupling efficiency simulated by two modeling methods. In the results of sinulation, ceil modeling method was preferred to annual modeling method in micro-optic device because of accuracy for coupling efficiency and Gaussian intensity distribution. In the results of optimal simulation for optical device using thin film filter, the distance (d1) between optical fiber and GRIN lens, the distance (d2) between GRIN lens and thin film filter and the coupling efficiency were 0.24 mm, 0.25 mm and -0.11 ㏈ respectively. As d2 was displaced at 0.25 mm and d1 was varied in order to evaluate the optimal value, d1 and maximum coupling efficiency were 0.24 mm and -0.35㏈, respectively. Then the results of experiment were corresponded to that of optimal simulation by cell modeling and it was possible to analyze the performance for optical device using thin film filter by the simulation.