• 제목/요약/키워드: Optic lens

검색결과 100건 처리시간 0.03초

비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se계 구조적, 광학적 특성 연구 (Structural and Optical Characteristics of ChalcogenideGe_Sb_Se for Basic Aspheric Lens Design)

  • 고준빈;명태식
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.133-137
    • /
    • 2014
  • The recent development of electro-optic devices and anticorrosion media has made it necessary investigate infrared optical systems with solid-solid interfaces of materials with amorphous characteristics. One of the most promising classes of materials for these purposes seems to be chalcogenide glasses, which are based on the Ge_Sb_Se system, have drawn much attention because of their use in preparing optical lenses and fibers that are transparent in the range of 3-12 um. In this study, a standard melt-quenching technique was used to prepare amorphous Ge_Sb_Sechalcogenideto be used in the design and manufacture of infrared optical products. The results of structural, optical, and surface roughness analyses of high purity Ge_Sb_Sechalcogenide glasses after various annealing processes reported.

비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se 광학계 및 결정화 특성 연구 (Chalcogenide Ge-Sb-Se Optical and Crystallization Characteristics for Basic a Planning Aspheric Lens)

  • 명태식;고준빈
    • 한국재료학회지
    • /
    • 제26권11호
    • /
    • pp.598-603
    • /
    • 2016
  • The recent development of electro-optic devices and anticorrosion media has led to the necessity to investigate infrared optical systems with solid-solid interfaces of materials that often have the characteristic of amorphousness. One of the most promising classes of materials for those purposes seems to be the chalcogenide glasses. Chalcogenide glasses, based on the Ge-Sb-Se system, have drawn a great deal of attention because of their use in preparing optical lenses and transparent fibers in the range of 3~12 um. In this study, amorphous Ge-Sb-Se chalcogenide for application in an infrared optical product design and manufacture was prepared by a standard melt-quenching technique. The results of the structural, optical and surface roughness analysis of high purity Ge-Sb-Se chalcogenide glasses are reported after various annealing processes.

검안렌즈 표준화의 필요성과 규격에 관한 연구 (The Necessity and Requirement of Trial Lens Set Standardization)

  • 박상열
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.217-223
    • /
    • 2006
  • 본 연구를 하게 된 목적은 전국의 약 7681개의 안경업소와 안과병 의원 그리고 콘택트렌즈 전문점에서 타각적 굴절 검사를 한 후 자각적 굴절 검사를 하기 위해 사용하는 검안렌즈세트(Trial lens set)가 표준화 된 규격이 미흡하고 안광학적 허용 오차도 규정되어 있지 않고 표기된 굴절력과 실제 렌즈 도수가 상의한 것이 많아 이를 개선하고 검안렌즈 규격에 표준화를 만들고자 이 연구를 하게 되었다. 연구방법으로는 검안렌즈 세트를 사용하는 안경사들을 대상으로 보수교육을 통해 설문조사를 실시하고 국내에서 사용하는 제품과 수입 제품을 사용하는 안경원을 설정하여 이들이 사용하는 김안렌즈 세트를 사용하기에 따라 5년 미만, 5~10년, 10년 이상 각 5곳씩 검안렌즈를 선정하였으며, 표기된 굴절력과 실제렌즈를 측정하여 일본공업규격(JIS T4402)과 비교 분석하여 보았다. 분석결과를 살펴보면 검안렌즈를 사용하는 사람들이 사용 중인 접안렌즈의 굴절력에 대한 신뢰성이 응답자의 80% 이상을 차지하고 구입후 한 번도 표기된 굴절력과 실제도수를 측정해보지 않았다. 또한 한국산업규격(KS P4402)은 1979년도에 제정되어서 현재 사용하는 렌즈세트에서 빠지는 도수가 많다. 응답자의 95% 이상이 시력검사시 불편함을 느끼고 있다. 또한 굴절력에 대한 오차는 사용기간이 오래된 검안렌즈 일수록 오차가 큰 것을 알 수 있었다. 결론은 우리나라도 검안렌즈 규격을 표준화시키고 한국산업규격(KS P4402)에서 규정된 렌즈 세트에서 빠지는 도수에 대한 렌즈 세트를 추가시켜야 된다고 생각한다. 그리고 표준화된 검안렌즈를 검사 및 관리 감독하는 기관도 만들어야 한다고 생각한다. 국내에서 생산하는 제품이나 외국에서 수입되는 제품도 독일이나 일본처럼 안광학적 허용오차를 규정히여 이를 검사하고 규격에 맞는 검안렌즈 세트가 유통되기를 바란다. 국민의 안보건 향상과 시기능 관리를 위해서 정확한 시력검사를 해야 하고 누구나 똑같은 표준화된 검안렌즈 세트를 사용하고 규격과 허용오차 범위를 벗어나지 않는 검안렌즈 세트가 규정되길 바란다.

  • PDF

착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화 (The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens)

  • 최현수;박성종;이석주;진문석;전진;유근창
    • 한국안광학회지
    • /
    • 제16권3호
    • /
    • pp.339-343
    • /
    • 2011
  • 목적: 본 연구에서는 안경렌즈의 색상과 농도에 따른 사위도의 변화를 알아보았다. 방법: 20~40세까지의 남녀 대학생 39명을 대상으로 무착색, 적색, 회색, 갈색, 녹색렌즈 를 각각 20%, 50%, 80%로 농도를 달리하여 착용 후 원거리 사위도를 측정하였다. 사위측정은 완전교정상태에서 포롭터(VT-SE, Topcon, Japan)를 이용하여 프리즘 분리법(Vongraefe technique)으로 측정하였다. 결과: 전체 대상자를 정위군, 내사위군, 외사위군으로 나누어서 실험하였다. 정위군에서는 모든 색상과 농도에서 약간의 내사위가 발생하였다. 내사위군에서는 평균 2.07${\Delta}$,BO 이던 사위도가 모든 색상과 농도에서 증가함을 보였고 특히, 갈색렌즈에서 가장 큰 증가를 보였다. 외사위군에서는 평균 3.82${\Delta}$,BI이던 사위도가 모든 색상과 농도에서 다소 감소함을 보였고 특히, 녹색렌즈에서 평균 2.95${\Delta}$,BI로 가장 큰 감소를 보였다. 같은 색상에서 농도를 달리하여 측정한 값은 통계적 유의성이 없었다. 결론: 안경렌즈의 색상에 따라 사위도의 변화가 확인되므로 렌즈의 색상을 선택함에 있어 사위도를 고려해야하며 안위이상의 피로도를 줄일 수 있는 색상을 찾는 기준이 마련되어야 할 것이라 사료된다.

구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구 (A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting)

  • 박성종;주석희;정주현
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.455-462
    • /
    • 2004
  • 근시성 굴절이상자 85명 170안을 대상으로 구면 RGP렌즈를 피팅(Fitting)하여 RGP시험렌즈 BCR별, 각막난시량별, 각막의 만곡도별 누액렌즈굴절력 변화를 측정하여 분석한 결과 다음과 같은 결론을 얻었다. 1. RGP시럼렌즈 BCR의 변경에 의한 누액렌즈 굴절력은 "on-k"에서 -0.25D, 0.05Ft는 -0.46D, 0.10Ft는 -0.63D, 0.05St는 +0.07D, 0.10St는 +0.26D를 보였다. 2. 각막난시량별 RGP렌즈 BCR의 변경에 의한 누액렌즈 굴절력은 "on-k" 상태에서 각막난시 0.75D이하는 -0.25D, 1.00~1.25D는 -0.18D, 1.50~1.75D는 -0.09D, 2.00D이상에서는 -0.39D를 나타냈다. 3. 각막난시량별 시험렌즈 BCR을 0.05mm단계로 변경함에 따른 누액렌즈 굴절력의 변화량은 0.05St와 0.05Ft에서는 ${\pm}0.25D$에 근사한값을 나타냈지만 0.10St와 0.10Ft에서는 ${\pm}0.25D$이하의 불안정한 누액렌즈값을 나타냈다. 4. 각막의 만곡도별 RGP렌즈 BCR의 변경에 의한 누액렌즈 굴절력용 "on-k" 상태에서 7.50mm이하는 -0.40D, 7.55~7.80mm는 -0.11D, 7.85~8.20mm는 -0.20D, 8.25mm이상은 -0.19D를 나타냈다. 5. 각막만곡도별 시험렌즈 BCR을 0.05mm단계로 변경함에 따른 누액렌즈 굴절력의 변화량은 각막의 만곡도가 클수록 감소하는 경향을 보였으며 8.25mm이상은 평균 ${\pm}0.17D$${\pm}0.25D$이하의 낮은 굴절력을 보였다.

  • PDF

망막 영상 조절 장치에 관한 연구 (A Study of the Retina Image Controllability using a Sledge)

  • 이숙희;이영춘;양연식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 1997
  • Seeing is an intelligent act. Retina is the most important part among the components of eye which is comprised of iris, pupil, lens, optic disk, and so forth. Because retina acts like a photo receiver to detect light from every object, if damaged, animals have a severe problem to live along with themselves and sometimes they lose their sight. In the ophthalmology, doctors use special instrument to see exact retina image of object and operate the surgery by rotating focus control knob. In this study, a basic test is done to achieve the auto focus control instrument. Specially made sledge and attenuator are installed on the optic bed to change the distance and laser power between the first reflective mirror and the second one. Control panel which is compiled by Visual C t t to control stepping motors ,laser power and photodiode are implemented with ADA-board.

  • PDF

Laser Beam Shaping Using Hollow Optical Fiber and Its Application in Laser Induced Thermal Printing

  • Yi, Jong-Hoon;Lee, Kang-In;Park, Ill-Hyun;Kwon, Jin-Hyuk
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.146-151
    • /
    • 2009
  • A Gaussian beam of single mode fiber laser was changed into a ring-shaped pattern after it was transmitted through the hollow optical fiber. The ring-shaped beam was focused on a plane by an f-. lens and it was scanned by a Galvano-mirror. The spatial profile of laser energy incident on a plane had two peaks at both sides of the scanned linear track. The profile was compared with the result obtained when the Gaussian beam was dithered transversely by an acousto-optic modulator. It is found that hollow optical fiber beam shaper can replace acousto-optic beam dithering device which is employed in a laser induced thermal printing system.

유전성대사질환에서 눈이상 (Inherited Metabolic Disorders Involving the Eye)

  • 정재호
    • 대한유전성대사질환학회지
    • /
    • 제22권2호
    • /
    • pp.37-45
    • /
    • 2022
  • Inherited metabolic disorders (IMD) are a large group of rare disorders affecting normal biochemical pathways. The ophthalmic involvement can be very varied affecting any part of the eye, including abnormalities of cornea, lens dislocation and cataracts, retina and the optic nerve, and extraocular muscles. Eye disorders can be initial symptoms of some IMD and can be clue for diagnosis of IMD. However, eye disorders can evolve later in the natural history of an already diagnosed metabolic disorder. Awareness of IMDs is important to facilitate early diagnosis and in some cases instigate early treatment if a patient presents with eye involvement suggestive of a metabolic disorder. Ophthalmological interventions are also an important component of the multisystem holistic approach to treating patients with metabolic disorders.

MO 근접장 기록을 위한 광학 갭 센서 (Optical Cap Sensor for Magneto-Optic Near-Field Recording)

  • 윤용중;박재혁;박노철;박영필
    • 대한기계학회논문집A
    • /
    • 제28권3호
    • /
    • pp.245-250
    • /
    • 2004
  • This paper proposes a new method of measuring an air interface distance between a solid immersion lens(SIL) applied magneto-optic technology and the disk surface. For applying near-field recording (NFR) technology to the magneto-optic storage devices for the next generation, it is positively necessary to maintain the small air gap under about 100㎚. We design an apparatus that consists of some optical components such as a prism, a polarizer and an analyzer. By using the Fresnel reflection coefficient equation, Jones matrices calculation and Malus's law, we establish a mathematical model for understanding the characteristics of the system. The simulations are based on the mathematical model and through the simulation results which is made with various cases we can estimate the performance of the new optical gap sensor system. Experimental results, which are also based on the mathematical model for specific cases, are in good agreement with simulated ones and demonstrate the possibility as the new optical gap sensor.

LED 2차 광학 시스템의 설계법 개발 (The Developement of Secondary Optics Design Method for LED)

  • 정승균;석대일;신화영;이창모;김훈
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.26-32
    • /
    • 2007
  • 기존의 LED 광학계의 설계법은 크게 점광원 가정법과 가초점 설계법이 있으나, 이 설계법들은 LED와 광학계간의 거리가 매우 좁아지게 될 경우 큰 오차가 발생하는 단점이 존재하였다. 본 논문에서는 LED를 등간격으로 분할하여 각부분의 배광을 예측하고, 광선의 역추적 기법을 활용하여 이에 대한 결과를 확인한 후 분할된 각 구간에 대하여 세그먼트의 개별적인 설계를 통하여 오차를 감소시키는 새로운 설계법을 제시한다. 설계법의 설명이후에 2종의 예시 광학계를 설계하고 광학 성능 예측 프로그램을 통하여 배광과 광학 효율을 평가하였다.