• Title/Summary/Keyword: Operational Parameter

Search Result 206, Processing Time 0.03 seconds

Performance Characteristics of High Frequency Jetting Dispenser Featuring Piezoactuator (압전작동기를 이용한 고주파수 젯팅 디스펜서의 성능 특성)

  • Yun, Bo-Young;Nguyen, Quoc Hung;Hong, Seung-Min;Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.595-600
    • /
    • 2007
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

  • PDF

Performance Characteristics of High Speed Jetting Dispenser Using Piezoactuator (압전작동기를 이용한 고속 토출 젯팅 디스펜서의 성능 특성)

  • Yun, Bo-Young;Nguyen, Quoc-Hung;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.432-438
    • /
    • 2008
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

Application of OMA on the bench-scale earthquake simulator using micro tremor data

  • Kasimzade, Azer A.;Tuhta, Sertac
    • Structural Engineering and Mechanics
    • /
    • v.61 no.2
    • /
    • pp.267-274
    • /
    • 2017
  • In this study was investigated of possibility using the recorded micro tremor data on ground level as ambient vibration input excitation data for investigation and application Operational Modal Analysis (OMA) on the bench-scale earthquake simulator (The Quanser Shake Table) for model steel structures. As known OMA methods (such as EFDD, SSI and so on) are supposed to deal with the ambient responses. For this purpose, analytical and experimental modal analysis of a model steel structure for dynamic characteristics was evaluated. 3D Finite element model of the building was evaluated for the model steel structure based on the design drawing. Ambient excitation was provided by shake table from the recorded micro tremor ambient vibration data on ground level. Enhanced Frequency Domain Decomposition is used for the output only modal identification. From this study, best correlation is found between mode shapes. Natural frequencies and analytical frequencies in average (only) 2.8% are differences.

ON OPTIMAL CONTROL OF A BOUNDARY VALUE PROBLEM

  • Kim, Hongchul;Rim, Gye-Soo
    • Korean Journal of Mathematics
    • /
    • v.6 no.1
    • /
    • pp.27-46
    • /
    • 1998
  • We are concerned with an optimal control problem governed by a Poisson equation in which body force acts like a control parameter. The cost functional to be optimized is taken to represent the error from the desired observation and the cost due to the control. We recast the problem into the mixed formulation to take advantage of the minimax principle for the duality method. The existence of a saddle point for the Lagrangian shall be shown and the optimality system will be derived therein. Finally, to attain an optimal control, we combine the optimality system with an operational technique. By achieving the gradient of the cost functional, a convergent algorithm based on the projected gradient method is established.

  • PDF

The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting (고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석)

  • Song, Jae-Joo;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

Series and Parallel Sin+Cos PSS (직렬 및 병렬 Sin+Cos 전력계통안정화장치)

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.87-89
    • /
    • 2005
  • This paper proposes new series and parallel Sin+Cos PSS(power system stabilizer) for the purpose to improve the existing PSS1A's performance. The purpose of PSS is used to enhance damping of power system oscillations through injection of auxiliary signal for an excitation control terminal. The Proposed series and Parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with serial and with parallel connection in a conventional PSS1A. The proposed controller is aim to considering of a damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The object of electric power system is KEPCO system and the voltage of power transmission line is a 154kV and a 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

  • PDF

Multi-functional Active-R Filter (다기능 능동-R 여파기)

  • 김익수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.10 no.4
    • /
    • pp.155-158
    • /
    • 1985
  • A simple active-R filter is proposed by utilizing only four resistors and two operational amplifiers. This filter has multi-functional characteristics and decreases the ratio of resistors. The sensitivity of $W_r$ and $Q_r$ as the parameter of filter is very low and the operating frequency of this active-R filter is possible in the high frequency. The integration of this active-R filter is easy due to the decrease in the number of resistors and the lowering of the ration of resistors. The experiment shows that all the characteristics of this active-R filter are in accordance with thory.

  • PDF

A Design of BJT-based ESD Protection Device combining SCR for High Voltage Power Clamps

  • Jung, Jin-Woo;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • This paper presents a novel bipolar junction transistor (BJT) based electrostatic discharge (ESD) protection device. This protection device was designed for 20V power clamps and fabricated by a process with Bipolar-CMOS-DMOS (BCD) $0.18{\mu}m$. The current-voltage characteristics of this protection device was verified by the transmission line pulse (TLP) system and the DC BV characteristic was verified by using a semiconductor parameter analyzer. From the experimental results, the proposed device has a trigger voltage of 29.1V, holding voltage of 22.4V and low on-resistance of approximately $1.6{\Omega}$. In addition, the test of ESD robustness showed that the ESD successfully passed through human body model (HBM) 8kV. In this paper, the operational mechanism of this protection device was investigated by structural analysis of the proposed device. In addition, the proposed device were obtained as stack structures and verified.

Impedance characteristic of human arm for cooperative robot

  • Rahman, Mozasser;Ikeura, Ryojun;Mizutani, Kazuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.85.3-85
    • /
    • 2002
  • In this study, we tried to investigate the impedance characteristic of human arm in a cooperative task. Human arm was moved in a desired trajectory. The motion was actuated by a 1 degree-of-freedom robot system. As the muscle is mechanically analogous to a spring-damper system, a second-order equation was considered as the model for arm dynamics. In the model, inertia, stiffness and damping factor were considered. The impedance parameter was estimated from the position and torque data obtained from the experiment and based on the "Estimation of Parametric Model". It was found that the inertia is almost constant over the operational time. The damping factor and stiffness were high...

  • PDF

Development of a Water Droplet Erosion Model for Large Steam Turbine Blades

  • Lee, Byeong-Eun;Riu, Kap-Jong;Shin, Se-Hyun;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.114-121
    • /
    • 2003
  • Water droplet erosion is one of major concerns in the design of modern large fossil steam turbines because it causes serious operational problems such as performance degradation and reduction of service life. A new erosion model has been developed in the present study for the prediction of water droplet erosion of rotor blades operated in wet steam conditions. The major four erosion parameter : impact velocity, impacting droplet flow rate, droplet size and hardness of target are involved in the model so that it can also be used for engineering purpose at the design stage of rotor blades. Comparison of the predicted erosion rate with the measured data obtained from the practical steam turbine operated for more than 90,000 hours shows good agreement.