• Title/Summary/Keyword: Operation time method

Search Result 3,413, Processing Time 0.034 seconds

Pressure sensor placement method for real-time operation efficiency of water transmission mains (도·송수관로의 실시간 운영효율화를 위한 수압계 설치위치 선정 방안)

  • Kim, Seong Han;Choi, Doo Yong;Kim, Kyoung Pil;Lee, Sang Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.491-500
    • /
    • 2016
  • Pressure monitoring is expected to be expanded in a water distribution system according to accelerated development of smart water network management technologies caused by appearances of affordable digital infrastructures like computing, storage and bandwidth. However, the placement of pressure sensors has been determined by engineer's technical decisions since there is no well-defined criteria for deciding a suitable location of pressure sensor. This study presents a placement method of pressure sensors based on the consideration of allowable error in calibrating water network analysis modeling. The proposed method is to find a minimum set of pressure sensors for achieving a reliable management of water transmissions main and increasing the efficiency of their real-time operation. In the case study in Y area's transmission main, the proposed method shows equally distributed pressure sensors in terms of hydraulics. It is expected that the proposed method can be used to manage transmission mains stably and construct a robust real-time network analysis system as a minimal criteria.

A study on the dressing time monitoring method of grinding wheel in surface grinding (연삭가공시 연삭숫돌의 드레싱 시기 검출 방법에 관한 연구)

    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.112-118
    • /
    • 1998
  • In surface grinding, the contact between the grinding wheel and workpiece introduce heat and resistance, which restrict the self-dressing of the grits and result in burrs and cracks on the workpiece. Therefore, before or during the grinding operation, it is necessary to self-dress the grinding wheel for more accurate performance. In order to determine the dressing time monitoring method of grinding wheel in surface grinding, a three-dimensional computer simulation of the grinding operation has been attempted based on the contact mechanism and surface-shaping system between the grinding wheel and the workpiece. The optimal dressing time is determined based on the grain wear and work surface roughness.

  • PDF

A Basis Study for Life Time Test of MCCB (배선용 차단기 수명평가를 위한 기초 연구)

  • Seo, Jung-Youl;Shin, Hee-Sang;Kim, Oh-Hwan;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.439-441
    • /
    • 2009
  • Recently, load circuits and components of customer are various. Therefore failures of ELB(Earth Leakage Breaker) and MCCB(Molded case circuit breakers) are more frequent. Lite time of MCCB even if there is same units differ from environment, condition of operation. FEMCA is a efficiency method of system operation or maintenance for system reliability. We study on FMECA procedures and method. In this paper, we focused on FMECA application to MCCB life time test.

  • PDF

Simulation of Ground Surface by In-process Measurement (인프로세스 측정을 통한 연삭 시뮬레이션)

  • Hong, Min-Sung;Choi, Woo-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.160-165
    • /
    • 1999
  • In surface grinding, the conditions of the grinding wheel give a significant effect on the ground workpieces comparing with other metal removal provesses. In this paper, to assist the development, a non-contacting optical method by the laser beam is introduced. The in-process measurement of scattering intensities has been made during surface grinding processes and the surface textures of wheel working surfaces are captured. Also, in order to determine the dressing time monitoring method of a grinding wheel, a three-dimensional computer simulation of the grinding operation has been attempted based on the contact mechanism and the surface-shaping system between the grinding wheel and the workpiece. The optimal dressing time is determined by the amount of the grain wear and work surface roughness.

  • PDF

Performance Improvement of High Speed Operation for Sensorless based Synchronous Machine (회전자 위치센서 없는 동기전동기의 고속 운전 성능 개선)

  • Jung, Young-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.439-444
    • /
    • 2018
  • The performance improvement in the high speed region for the sensorless based synchronous machine drive is discussed in the paper. Conventional dynamic overmodulation method in the vector controlled AC driver requires some calculation of maximum amplitude of the applying voltage vector to limit its amplitude, which leads to increase the calculation time of microprocessor. For low performance microprocessor, this might be impossible to complete the control loop within limited control time. Thus, to reduce the calculation time, the constantly limited amplitude for applying voltage vector is tried in this paper to drive sensorless based synchronous motor. Certainly, there exists some errors in amplitude and phase angle between inverter voltage and calculating voltage in the sensorless algorithm. But, this errors are too small to prevent the high speed sensorless operation within overmodulation region. The validities of the proposed method is proved by the experimental results.

The Effectiveness of Meridian Acupressure Intervention Using Sticker Needles to Bowel Movement on Post Spinal Operative Patients (스티커 침을 이용한 경혈지압이 척추수술 후 배변에 미치는 영향)

  • Kim, Yang-Kuem;Lee, Hyang-Yeon
    • Journal of East-West Nursing Research
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 2005
  • This study was conducted to identify the effect of meridian acupressure on defecation of patients with post spinal operation. The nonequivalent control group posttest only design was used. The data were obtained from 77 post spinal operative patients, 34 in the experimental 43 in control group in Y Hospital, Seoul, Korea. The neurosurgical unit A and B ward, assigned by matched sample by the name of operation such as laminectomy and posterior lumbar interbody fusion are performed. Meridian acupressure meant the method that an examiner presses response points distributed in the pass of energy vessel. In this study, meridian acupressure program was performed on as points in order of Hegue (LI-4), Zhigou (TE-6), Zusanli (S-36), Shangjuxu (S-37), Xiajuxu (S-39), Tianshu (S-25), Taichong (L-3) which was known to be related to large intestine. Data were collected from 1, July 2003 to 1, September 2003. Meridian acupressure program was carried out for 20 minutes 4 hours after operation twice daily. In order to evaluate the effect of meridian acupressure intervention, they were asked time of bowel recovery, gas passing, and defecation though questionnaire method. Data were analyzed by the SPSS/ WIN 11.0 program. The results of this study were summarized as follows; 1. Homogeneity tests of general characteristics and operation related characteristics of the experimental group and the control group were performed. General characteristics included age, sex, defecation habit, eating pattern, fluid intake, life style, activity, usage of laxative and etc. 2. Hypotheses were verification as follows; 1) Recovery of bowel sound of the experimental group who received meridian acupressure intervention was faster than that of the control group after spinal operation (t=-6.770,P=.000). 2) Time of gas passing of the experimental group who received meridian acupressure program was faster than that of the control group after spinal operation (t=-8.003, P=.000). 3) Time to defecation of the experimental group who received meridian acupressure program was faster than that of the control group after spinal operation (t=-9.026, P=.000). 4) Abdominal discomfort due to defecation of the experimental group who received meridian acupressure program was lesser than that of the control group after spinal operation (t=-3.431, P=.001). From these results, meridian acupressure intervention was effective for recovery of bowel sound, reduce time to gas passing, time to defecation and lessen abdominal discomfort due to defecation on post spinal operative patients. And therefore this intervention can probably considered on clinical practice.

  • PDF

Network-type Cell Layout in Cellular Flexible Assembly Systems (셀형유연조립시스템에서의 네트웍형 셀배치)

  • 노인규;최형호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.39
    • /
    • pp.63-73
    • /
    • 1996
  • With the success of flexible manufacturing systems (FMSs), flexible assembly systems (FASs) have been developed to automate factories further. As in a cellular FMS, a cellular FAS is considered as the most flexible and feasible assembly system configuration Because of the differences between manufacturing and assembly operation, the logic of cell formation and cell layout between a FMS and a FAS is not the same. Since the time for assembly operation is usually relatively short, the transfer time is thus very crucial for the performance of assembly systems. Therefore in assembly systems it is important to reduce the transfer time by sequencing operations efficiently and arranging machines like the sequences. The network-type layout is not only feasible for the machine arrangement based on operation sequences, but it has also layout flexibility. Therefore it is a reasonable layout configuration for cellular FASs. This paper presents a method for the cell layout based on the network-type layout in a cellular FAS design.

  • PDF

New Method to Quantify the Operation Condition for Zone 3 Impedance Relays during Low-Frequency Power Swings

  • Li, Shenghu
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.29-35
    • /
    • 2008
  • With long time setting, zone 3 impedance relays are considered insensitive to power swings, and their operation condition during power swings is seldom analyzed. Instead of ti me-consuming simulation to the swing loci, their operation condition is directly quantified by polynominal functions in this paper to find the critical swing angle and frequency for relay operation under different relay settings and system parameters. It is found: (1) the swing loci are more densely populated inside than outside of the protection region, which corresponds to long residence time and possible relay operations; (2) the relays may be sensitive to load encroac hments and stable power swings with different relay settings and system parameters; (3) the critical swing frequency may be in the range of low-frequency power swings.

C-arm Guided Closed Reduction of Zygomatic Arch Fracture (C-arm 투시하에서 관골궁 골절의 비관혈적 정복술에 관한 고찰)

  • Eo, Yoon-Ki;Lee, Dong-Kun;Kim, Jeong-Sam;Jang, Young-Il
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.23-26
    • /
    • 1999
  • The Zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Ailing and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients.

  • PDF

Thermal Fatigue Degradation Behavior of Ni-Ti Shape Memory Alloy (Ti-Ni 형상기억합금의 열피로열화 거동)

  • 박영철;조용배;오세욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2913-2921
    • /
    • 1994
  • In SMA(shape memory alloy), the degradation by fatigue is one of the most important problems to be overcome, when SMA is used for robot-actuator material. The actuator is operated repeatitively for long time and its repeating operation develops the fatigue degradation of SMA. The fatigue degradation changes the transformation temperature and deformation behavior and results in inaccurate operation control of robot. Accordingly, the changing behavior of transformation temperature and deformation which results from repeating operation is to be investigated in advance and the scheme to resolve those problems have to be made for the design of actuator. In this study, the fatigue tests were carried out on SMA specimens prepared to have different condition of aging time and pre-strain with the direct-current heating-cooling method, which was a general method of operation in robot actuators. The behavior of transformation temperature and deformation were examined and analyzed in each specimen and the study was performed to establish the optimistic manufacturing condition of SMA against the fatigue degradation.