• Title/Summary/Keyword: Operation margin

Search Result 402, Processing Time 0.029 seconds

Verification of Seismic Safety of Nuclear power Plants (원자력발전소의 내진 안정성 확보)

  • 이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.3-16
    • /
    • 2000
  • The ultimate safety-goal of nuclear power plants should be targeted at preventing release of nuclear radiation compared to general structures, Accordingly the phases of siting design construction and operation of NPPs are severely regulated by codes of aseismic design so as to assure safety of NPPs. To accomplish this goal strict quality assurace and seismic qualification tests should be conducted for all phases of NPP construction. In addition seismic monitoring systems should be installed and always in operation to provide proper post-earhquake procedures. Besides periodic safety review should be performed during operation along with the seismic margin assessment. In this paper general procedures to secure seismic safety of NPPs are systematically reviewed and additional considerations for improvement are suggested.

  • PDF

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

Surgical Complications of Cerebral Arterivenous Malformation and Their Management (뇌동정맥기형의 외과적 수술합병증과 그 처치)

  • Yim, Man-Bin;Kim, Il-Man
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1126-1135
    • /
    • 2000
  • Objectives : The goal of surgical management of cerebral arteriovenous malformation(AVM) is elimination of the lesion without development of new neurological deficits. To improve the management results of cerebral AVMs in the future, this article discusses about surgical complications of the AVM and their management. Material and Methods : During the past 18 years, 116 patients with cerebral AVMs were managed by surgery. Among these cases, 7 cases died, 7 cases developed new neurological deficits, 11 cases residual AVM and 5 cases intracerebral hematoma(ICH) after surgery. The author analyzes the causes of those complications and investigates the methods to minimized those complications based on the review of the literatures. Results : One stage removal of AVM and ICH in the poor neurological state were performed in 5 of 7 death cases. Subtotal removal of ICH followed by delayed AVM surgery after recovery is regard as one method to improve the outcome of patient with large ICH. Postoperative new neurological deficits developed owing to normal perfusion pressure breakthrough(NPPB) in 3, judgement error in 2, preoperative embolization in 1 and cortical injury in 1 case(s). Proper management of NPPB, accurate anatomical knowledge and physiological monitoring during operation, and well trained skill for embolization are regard as methods to minimize those complications. Residual AVMs after surgery were noticed in 11 cases, in which unintended 6 cases due to inaccurate dissection of peripheral margin of AVM, and intended 3 cases due to massive brain swelling during operation, 1 cases due to diffuse type and 1 case due to multiple type of AVM. Accurate dissection of peripheral margin of AVM and mild hypotension during operation may help to avoid this complication. Postoperative hemorrhage occurred in 3 cases due to rupture of the residual AVM and in 2 cases due to oozing from the AVM bed. Complete resection of AVM, complete control of bleeding points at AVM bed and mild hypotension during early postoperative period are the methods to avoid this complication. Conclusion : A precise but flexible therapeutic strategy and refined skill for endovascular, radiosurgical and microsurgical techniques are required to successful treatment of cerebral AVM. Adequate timing of AVM resection, accurate anatomical knowledge, proper management of NPPB and accurate dissection of peripheral margin of AVM are the key points for avoiding complications of the AVM surgery.

  • PDF

A Study on the operation status and improvement of EMU (Empty Management Unit) (EMU(Empty Management Unit)의 운영현황 및 개선방안에 관한 연구)

  • Kim, Ki-Young;Nam, Tae-Hyun;Kong, Jeong-Min;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.15 no.12
    • /
    • pp.273-282
    • /
    • 2017
  • The purpose of this study is to investigate the changes in the recovery of equipment using full containers loaded with freight instead of direct container transportation according to the sales policy considering the cost of transporting the containers. The EMU operation case was analyzed. The policies implemented by Company A to provide EMU credits depended only on the relative accountability contribution margin per box (RA CMPB) for the profitability of backhaul full freight. Therefore, these policies resulted in limitations in sales based on profitable accountability (PA) CMPB, which is more profitable. Moreover, while some Asian regions have surplus equipment, many Asian destinations to which their freight is exported have equipment shortages. Thus, in some cases, service sales to the regions with surplus equipment generated greater company-wide profits when compared with the return of empty containers or sales to the regions with insufficient equipment. In other words, the conditions for providing EMU credits should be changed, and even the full freight between regions with surplus equipment should be provided with credit amounts in which potential factory and transport costs in a destination are pre-reflected.

Rastelli operation in Persistent Truncus Arteriosus, Type IV: A Case Report (총동맥간 잔류증 [IV 형]Rastelli 수술 치험 보고)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.333-341
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF

CCD Image Sensor with Variable Reset Operation

  • Park, Sang-Sik;Uh, Hyung-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2003
  • The reset operation of a CCD image sensor was improved using charge trapping of a MOS structure to realize a loe voltage driving. A DC bias generating circuit was added to the reset structure which sets reference voltage and holds the signal charge to be detected. The generated DC bias is added to the reset pulse to give an optimized voltage margin to the reset operation, and is controlled by adjustment of the threshold voltage of a MOS transistor in the circuit. By the pulse-type stress voltage applied to the gate, the electrons and holes were injected to the gate dielectrics, and the threshold voltage could be adjusted ranging from 0.2V to 5.5V, which is suitable for controlling the incomplete reset operation due to the process variation. The charges trapped in the silicon nitride lead to the positive and negative shift of the threshold voltage, and this phenomenon is explained by Poole-Frenkel conduction and Fowler-Nordheim conduction. A CCD image sensor with $492(H){\;}{\times}{\;}510(V)$ pixels adopting this structure showed complete reset operation with the driving voltage of 3.0V. The resolution chart taken with the image sensor shows no image flow to the illumination of 30 lux, even in the driving voltage of 3.0V.

Remote Nozzle Blocking Device of RCS Pipe during Mid-Loop Operation in Nuclear Power Plants

  • Kang, Ki-Sig;Lee, Se-Yub;Chi, Ham-Chung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.571-576
    • /
    • 1996
  • Currently most nuclear power plants(NPPs) are adopted the mid-loop operation to minimize the overhaul period and save the operating cost. For mid-loop operation it is essential to install nozzle dam between RCS pipe and steam generator(SG). Because SG remains more highly contaminated with radioactive material than any other parts of the NPPs, the repairmen are very reluctant to carry out installing nozzle dam inside the SG. Until now, unfortunately, it appears that no practically applicable device was developed to provide the longstanding demand. Also the accidents have been reported by licenser event report during this operation mode due to loss of residual heat removal(RHR). The purpose of this paper is to conduct remotely blocking and disintegration of nozzle of a SG which has the highest radiation exposure during the maintenance in NPPs. The remote nozzle blocking device of a SG includes three bladders, hubs, air controller provisions to supply and contact air pressure into the bladders. This remote nozzle block device will give the larger operation margin to prevent the loss of RHR and minimize the radiation exposure dose to the repairman and shorten the overhaul periods.

  • PDF

System State Identification using Transmission Loss (송전손실에 의한 전력시스템의 상태식별법)

  • Lee, Hyung-Soo;Shim, Keon-Bo;Lee, Bong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.196-200
    • /
    • 1992
  • Transmission loss retains a complete set of system state information. If we could exploit its behavior, we could find various useful applications. This study is a such exploitation to find same possibilities of the loss application. It seems to have very prospective possibilities. It has been tried to establish some network indices to indicate operation margin. And further some prospective applications are suggested.

  • PDF

RF Compatibility Test Results of COMS satellite with Launch Vehicle (천리안위성의 발사체와의 전자파 적합성 시험결과 분석)

  • CHOI, Jae-Dong
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.215-217
    • /
    • 2010
  • This paper describes the test results of radiated compatibility with Ariane 5 launcher performed on the COMS Satellite test facility. Firstly, the Radiated Emission test results are analyzed in compliance with the Radiated Susceptibility requirement specification of Ariane 5 launcher. The satellite nominal operation is monitored during injection a radiated electric field corresponding to the launcher emissions levels in critical frequency ranges. And also, E-field are measured through a probe located at external units level in order to assess the EMC safety margin in Radiated mode.

  • PDF

Ebstein`S Anomaly: A Case Report of Plication and Tricuspid Valve Replacement (Ebstein 심기형 수술 1례[Plication 및 삼첨판막 이식예])

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.342-347
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF