• Title/Summary/Keyword: Operation margin

Search Result 402, Processing Time 0.028 seconds

PRAM용 상변화 소재인 AgInSbTe의 전기적 특성에 대한 연구

  • Hong, Seong-Hun;Bae, Byeong-Ju;Hwang, Jae-Yeon;Lee, Heon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.19.1-19.1
    • /
    • 2009
  • Phase change random access memory (PRAM)은 large sensing signal margin, fast programming speed, low operation voltage, high speed operation, good data retention, high scalability등을 가지는 가장 유망한 차세대 비휘발성 메모리이다. 현재 PRAM용 상변화 재료로는 주로 Ge2Sb2Te5가 사용되고 있지만 reset 전류가 높고 reliability 가 좋지 않아서 새로운 상변화 물질 연구가 필요하다. AgInSbTe (AIST)는 GST와 더불어 열에 의한 가역적 상변화를 하는 소재로 광기록 매체에서는 기록 속도가 빠르고 동작 특성이 우수하다는 특징이 있다. 본 연구에서는 XRD, 비저항측정등을 통해 온도에 따른 AIST의 물성 및 결정화 특성을 분석하고 나노 소자제작을 통해 그 전기적 특성을 평가하였다.

  • PDF

Sorted compressive sensing for reconstruction of failed in-core detector signals

  • Gyu-ri Bae;Moon-Ghu Park;Youngchul Cho;Jung-Uk Sohn
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1533-1540
    • /
    • 2023
  • Self-Powered Neutron Detectors(SPNDs) are used to calculate core power distributions, an essential factor in the safe operation of nuclear power plants. Some detectors may fail during normal operation, and signals from failed detectors are isolated from intact signals. The calculated detailed power distribution accuracy depends on the number of available detector signals. Failed detectors decrease the operating margin by enlarging the power distribution measurement error. Therefore, a thorough reconstruction of the failed detector signals is critical. This note suggests a compressive sensing based methodology that rationally reconstructs the readings of failed detectors. The methodology significantly improves reconstruction accuracy by sorting signals and removing high-frequency components from conventional compressive sensing methodology.

A study of the Infantry Backpack System for Portability and Mobility Performance (보병용 배낭의 휴대 및 이동 성능에 관한 연구)

  • Chung, SungHak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.3
    • /
    • pp.155-161
    • /
    • 2014
  • The objective of this study is to weight analysis portable backpack system of infantry weapon systems for ergonomic design in manual materials handling tasks. For the product design, we analyzed the ergonomic guidelines and status of similar weapon systems by comparing the efficient operation performance provide for the basic data. Result of this study, the relationship between portability and mobility presented for schematic. In the short distance of the short biomechanical criterion, 1-2 hours in the middle of moving psychophysical criterion, 4 hour or more long-distance criterion applied for the physiological criterion for easy of trade-offs that need to be considered. This study suggests for 4 research items for infantry backpack system in manual materials handling tasks. Throughout the result of anthropometric populations, the 5%tile body weight for -0.91kg but 95%tile in 34.17kg considered to be margin for free, easy and efficient operation for the weight margin between portability and mobility in manual materials handling tasks.

A Modified McIndoe Operation for Treatment of Vaginal Agenesis (개량된 McIndoe 술식을 이용한 무질증 환자의 질 재건)

  • Tark, Kwan Chul;Choi, Bong Kyoon;Choi, Jong Woo
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2005
  • The reconstructive modalities for vaginal reconstruction include simple dilatation, skin graft, use of intestinal segments and various methods using flaps. However, skin grafting procedure is the most commonly used technique and the McIndoe procedure is a representative technique among skin grafting procedures. McIndoe procedure is easier, faster and has a lower morbidity compared to other techniques. However the conventional McIndoe procedure has several problems such as incomplete vestibule formation, excessive bleeding during dissection, possibility of recto-vaginal or urethro-vaginal fistula formation, late vaginal contracture and discomfort in wearing hard plastic mold for a long time after operation. To solve these problems, the authors modified the conventional McIndoe procedure in several perspectives. The undeveloped vestibule was incised with X-shaped mucosal incision between the urethral opening and posterior margin of the vestibule and deepened by blunt finger dissection to provide a sufficient diameter & length of the neovagina and to minimize bleeding. A sizable medium thickness split skin graft was harvested and wrapped over a roll gauze-filled condom mold. Applying multiple stab incision on the skin grafted condom mold, it was inserted into the prepared neovaginal canal. Distal margin of the skin graft was secured with tips of the mucosal flaps created by X-shaped vestibular incision to prevent accidental extrusion of the skin grafted mold. During last 15 years, we applied this modification to 20 vaginal agenesis patients and investigated results of the 12 patients who could be followed up serially including hematoma formation and skin graft survival rate, size, depth, presence of late contracture, appearance, comfortness, and hygiene of the neovagina. And they were compared with 8 patients of 20 patients who underwent conventional McIndoe procedures. The modified McIndoe procedure revealed lower complication rate, higher patient satisfaction and better functional results.

Safety Margin Improvement Against Failure of Zr-2.5Nb Pressure Tube (Zr-2.5Nb압력관 파손에 대한 안전여유도 개선)

  • Jeong, Yong-Hwan;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.775-783
    • /
    • 1995
  • This study is to assess the effects of increasing wall thickness on the safety margin of pressure tube in operating and of lowering initial hydrogen concentration on the DHC growth in respect to the improvement of the reliability of pressure tube in CANDU reactors. The pressure tube with thicker wall of 5.2 mm shows much higher safety margin for flaw tolerance by 25% than the current 4.2mmm tube. The thicker pressure tubes have a great benefit in LBB assessment including the initial crack depth at which DHC occurs, the crack length at onset of leaking and the available time for action. The resistance for the pressure tube ballooning at LOCA accident is also increased with the thicker tube. The calculations for Heq concentration after 20 years of operation as a function of wall thickness and initial hydrogen concentration show that the 5.2 mm nil thickness tube with 5 ppm initial hydrogen concentration is the most resistant to DHC. with the lower initial hydrogen concentration, TSS temperature for the precipitation or hydride decreases and the crack growth during cooldown reduces.

  • PDF

Study of the Flow in Centrifugal Compressor

  • Xu, Cheng;Amano, Ryoichi Samuel
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.3
    • /
    • pp.260-270
    • /
    • 2010
  • Reducing the losses of the tip clearance flow is one of the keys in an unshrouded centrifugal compressor design and development because tip clearances are large in relation to the span of the blades and also centrifugal compressors produce a sufficiently large pressure rise in single stage. This problem is more acute for a low flow high-pressure ratio impeller design. The large tip clearance would cause flow separations, and as a result it would drop both the efficiency and surge margin. Thus a design of a high efficiency and wide operation range low flow coefficient centrifugal compressor is a great challenge. This paper describes a recent development of high efficiency and wide surge margin low flow coefficient centrifugal compressor. A viscous turbomachinery optimal design method developed by the authors for axial flow machine was further extended and used in the centrifugal compressor design. The compressor has three main parts: impeller, a low solidity diffuser and volute. The tip clearance is under a special consideration in this design to allow impeller insensitiveness to the clearance. A patented three-dimensional low solidity diffuser design method is used and applied to this design. The compressor test results demonstrated to be successful to extend the low solidity diffusers to high-pressure ratio compressor. The compressor stage performance showed the total to static efficiency of the compressor being about 85% and stability range over 35%. The test results are in good agreement with the design.

A Study on the Display Discharge Characteristics of PDP for the HDTV (HDIV를 위한 PDP의 표시방전특성에 관한 연구)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.39-46
    • /
    • 2005
  • This research concerns the ADS drive method of 3 electrodes AC PDP and is determined the minimum pulse width of the address and the sustain, which the steady sustain discharge without decreasing luminance can be obtained. From the experimental result, if the address pulse width became $1.5[{\mu}s]$ or more a effective address discharge with the operating margin of 35[V] was possible. And if the sustain pulses width became $2[{\mu}s]$ or more, a steady sustain discharge with the operation margin of 25[V] was possible. When this condition is applied to Full-HDTV class PDP with the in lines of horizontal scanning lines, 8 sub-fields and total 1420 sustain pulses can be used.

Surgical Margins for Excision of Dermatofibrosarcoma Protuberans (융기성 피부섬유육종의 외과적 절제연)

  • Bae, Yong Chan;Moon, Jae Sul;Nam, Su Bong
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.454-460
    • /
    • 2005
  • Dematofibrosarcoma protuberans(DFSP) is a moderate-degree malignant tumor with high recurrence rate and low metastasis rate, from soft tissue. Principle of treatment is wide excision or Mohs micrographic surgery(MMS). Although wide excision has been performed with surgical margins of 2-5 cm until nowadays, there are problems of preservation of surrounding normal tissue. Therefore the authors tried to identify desirable surgical margins and operative method. From January 1999 to April 2003, 12 patients with DFSP were operated. We applied different surgical margins and operative methods according to the location of lesions. On the face, we performed MMS with surgical margin of 3-4 mm in 2 cases although there are problems of operation time and expense. But on the extremities and trunk, we performed authors' method to begin excising with surgical margins of 1 cm and excise extensively with MMS by 1 cm in 4 cases after April, 2001 although we had performed wide excision with surgical margin of 3 cm in 6 cases before. There was no recurrence or metastasis in the follow-up period. So we think that author's method is effective in surgical excision of DFSP

Analysis of effect of parasitic schottky diode on sense amplifier in DDI DRAM (DDI DRAM의 감지 증폭기에서 기생 쇼트키 다이오드 영향 분석)

  • Chang, Sung-Keun;Kim, Youn-Jang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.485-490
    • /
    • 2010
  • We propose the equivalent circuit model including all parasitic components in input gate of sense amplifier of DDI DRAM with butting contact structure. We analysed the effect of parasitic schottky diode by using the proposed model in the operation of sense amplifier. The cause of single side fail and the temperature dependence of fail rate in DDI DRAM are due to creation of the parasitic schottky diode in input gate of sense amplifier. The parasitic schottky diode cause the voltage drop in input gate, and result in decreasing noise margin of sense amplifier. therefore single side fail rate increase.

Automated Surgical Planning System for Spinal Fusion Surgery with Three-Dimensional Pedicle Model (척추 융합 수술을 위한 삼차원 척추경 모델을 이용한 자동 수술 계획 시스템)

  • Lee, Jong-Won;Kim, Sung-Min;Kim, Young-Soo;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.807-813
    • /
    • 2011
  • High precision of planning in the preoperative phase can contribute to increase operational safety during computer-aided spinal fusion surgery, which requires extreme caution on the part of the surgeon, due to the complexity and delicacy of the procedure. In this paper, an advanced preoperative planning framework for spinal fusion is presented. The framework is based on spinal pedicle data obtained from CT (Computed Tomography) images, and provides optimal insertion trajectories and pedicle screw sizes. The proposed approach begins with safety margin estimation for each potential insertion trajectory that passes through the pedicle volume, followed by procedures to collect a set of insertion trajectories that satisfy operation safety objectives. The radius of a pedicle screw was chosen as 70% of the pedicle radius. This framework has been tested on 68 spinal pedicles of 8 patients requiring spinal fusion. It was successfully applied, resulting in an average success rate of 100% and a final safety margin of $2.44{\pm}0.51mm$.