• Title/Summary/Keyword: Operation layer

Search Result 1,096, Processing Time 0.272 seconds

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 3. Effect of Organic Matters at $N_2$ Back-flushing (세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 3. 질소 역세척 시 유기물의 영향)

  • Park, Jin Yong;Han, Ji Soo
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.171-177
    • /
    • 2012
  • Effect of humic acid (HA), photo-oxidation and adsorption with periodic $N_2$ back-flushing was investigated in hybrid process of ceramic ultrafiltration and photocatalyst for drinking water treatment. It was compared and investigated with the previous result at water back-flushing in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As decreasing HA, $R_f$ decreased dramatically and J increased, and finally $V_T$ was the highest at HA 2 mg/L. As HA concentration increased from 2 to 10 mg/L, the membrane fouling resistance after 180 mins' operation ($R_{f,180}$) improved 0.8 times more than that of water back-flushing. Therefore, HA concentration should affect on the membrane fouling at $N_2$ back-flushing than water back-flushing. Turbidity treatment efficiencies were almost constant independent of HA concentration, but HA treatment efficiency was the maximum at HA 2 mg/L. This means that adsorption and photo-oxidation of photocatalyst beads could removed HA at HA 2 mg/L, but it was not enough at 4 mg/L. Beyond HA 6 mg/L, UF could effectively treat HA by thick cake layer on membrane surface and severe inner membrane fouling.

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

A Study on the Activated Carbon Injection and Filtration Process for Removal of Chlorinated Organic Compound in the Incinerator Flue Gas (활성탄의 분무 여과에 의한 소각로 배가스 중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Due to the toxicity of dioxin in the incinerator flue gas, it becomes a severe social problem. Activated carbon adsorption process is one of the methods for removing dioxin in the flue gas and was investigated its performance for removing hazardous organic compounds. Since dioxin is very hazardous material, 1,2-dichlorobenzene(o-DCB), one of the precursor material of dioxin, was used as adsorbate. The effects of air flow rate, pressure drop in the bag filter, operation temperature of bag filter, and kinds of adsorbents on the removal of o-DCB were measured and analysed. Experimental results showed that the operating temperature was recommended within the range of $140{\sim}170^{\circ}C$ considering the operating condition of incinerator. Also it was necessary to maintain the pressure drop of bag filter $120mmH_2O$ for enhancing the adsorption at the surface layer of activated carbon formed on the bag filter. The use of mixture of same amount of activated carbon and diatomite showed more than 90% removal of o-DCB and also reduced the consumption of activated carbon.

  • PDF

Time-Dependent Modeling of Performance Degradation for PEMFC Single Cell System to Evaluate the Cell Performance and Durability: Effects of CO Poisoning (고분자전해질 연료전지의 성능과 안정성 시험을 위한 단위전지의 시간 경과에 따른 모델링: 일산화탄소 피독현상에 의한 효과)

  • Kim, Jong-Sik;Kim, Pil;Joo, Ji-Bong;Kim, Woo-Young;Yi, Jong-Heop
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • There have been great attentions on polymer electrolyte membrane fuel cell (PEMFC) due to their advantageous characteristics such as zero emission of hazardous pollutant and high energy density. In this work, we evaluated degradation phenomena and stability of single cell performance via one dimensional single cell modeling. Here, CO poisoning on anode on anode was considered for cell performance degradation. Modeling results showed that the performance and stability were highly degraded with CO concentration in fuel gas. In addition, cell performance was reduced by slow oxygen reduction on cathode in long term operation. In order to overcome, it is required to increase ratio o#hydrogen in the fuel gas of anode and high Pt loading contained in the cathodic catalyst layer.

  • PDF

Comparison of Environmental Impacts of Green and Traditional Buildings using Life Cycle Assessment (전과정평가(LCA)를 이용한 친환경 인증 건축물과 일반 건축물의 환경영향 비교 사례 연구)

  • Hong, Taehoon;Jeong, Kwangbok;Ji, Changyoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.3
    • /
    • pp.58-65
    • /
    • 2014
  • This study aims to understand the environmental impact reduction of green buildings that are certified by Green standard for energy and environmental design(G-SEED). To ensure this end, this study assessed and compared the environmental impacts(global warning, ozone layer depletion, acidification, and eutrophication) of a G-SEED-certified elementary school building(green building) and an uncertified elementary school building(traditional building) using the life cycle assessment methodology. This study considered the environmental impacts from the material manufacturing, material transportation, on-site construction, and operation during 40 years. The comparison of the environmental impact intensity of two buildings showed that the green building generated much more environmental impacts than the traditional building. For example, the global warming potential of the green building was approximately 12.5% higher than of the traditional building since the global warming potential of the green building was 3.751 $t-CO_2eq./m^2$ while that of the traditional building was 3.282 $t-CO_2eq./m^2$. It signifies that the G-SEED doesn't guarantee the reduction of the environmental impacts in terms of four impact categories. Therefore, the G-SEED should be complemented and improved to achieve the environmental impact reduction.

An Efficient Page-Level Mapping Algorithm for Handling Write Requests in the Flash Translation Layer by Exploiting Temporal Locality (플래시 변환 계층에서 시간적 지역성을 이용하여 쓰기 요청을 처리하는 효율적인 페이지 레벨 매핑 알고리듬)

  • Li, Hai-Long;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1167-1175
    • /
    • 2016
  • This paper proposes an efficient page-level mapping algorithm that reduces the erase count in the FTL for flash memory systems. By maintaining the weight for each write request in the request buffer, the proposed algorithm estimates the degree of temporal locality for each incoming write request. To exploit temporal locality deliberately for determination of hot request, the degree of temporal locality should be much higher than the reference point determined experimentally. While previous LRU algorithm treats a new write request to have high temporal locality, the proposed algorithm allows write requests that are estimated to have high temporal locality to access hot blocks to store hot data intensively. The pages are more frequently updated in hot blocks than warm blocks. A hot block that has most of invalid pages is always selected as victim block at Garbage Collection, which results in delayed erase operation and in reduced erase count. Experimental results show that erase count is reduced by 9.3% for real I/O workloads, when compared to the previous LRU algorithm.

Energy Harvesting Characteristics of Interdigitated (IDT) Electrode Pattern Embedded Piezoelectric Energy Harvester (IDT 전극 패턴 임베디드 압전 에너지 하베스터의 특성)

  • Lee, Min-seon;Kim, Chang-Il;Yun, Ji-sun;Park, Woon Ik;Hong, Youn-Woo;Paik, Jong Hoo;Cho, Jeong Ho;Park, Yong-Ho;Jang, Yong-Ho;Choi, Beom-Jin;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.581-588
    • /
    • 2016
  • Piezoelectric thick films of a soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material were produced by a conventional tape casting method. Thereafter, the interdigitated (IDT) Ag-Pd electrode pattern was printed on the $25{\mu}m$ thick piezoelectric film at room temperature. Co-firing of the 10-layer laminated piezoelectric thick films was conducted at $1,100^{\circ}C$ and $1,150^{\circ}C$ for 1 h, respectively. Piezoelectric cantilever energy harvesters were successfully fabricated using the IDT electrode pattern embedded piezoelectric laminates for 3-3 operation mode. Their energy harvesting characteristics were investigated with an excitation of 120 Hz and 1 g under various resistive loads (ranging from $10k{\Omega}$ to $200k{\Omega}$). A parabolic increase of voltage and a linear decrease of current were shown with an increase of resistive load for all the energy harvesters. In particular, a high output power of 3.64 mW at $100k{\Omega}$ was obtained from the energy harvester (sintered at $1,150^{\circ}C$).

Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery (성형외과 영역에서 이물질 주사에 대한 고해상초음파 검사의 유용성)

  • Ko, Eung-Yeol;Sung, Ha-Min;Cho, Geon;Park, Young-Kyu;Tak, Kyoung-Seok;Suh, In-Suck;Yang, Ik
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.385-390
    • /
    • 2010
  • Purpose: The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body. Methods: From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12 MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal (7), foreign body removal and corrective plastic surgery (4), and conservative treatment with antibiotics and steroid injection (2). Results: High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared. Conclusion: Considering the usefulness of highresolution ultrasonography in foreign body injection, highresolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.

The facial tissue expansion to achieve the natural cervicomental angle (자연스러운 목턱각 성형을 위한 안면부 조직확장술)

  • Lee, Ki Eung;Koh, Jang Hyu;Seo, Dong Kook;Lee, Jong Wook;Choi, Jae ku;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.629-636
    • /
    • 2009
  • Purposes: Wide scars occurring on the lower face and neck are a source of both functional and esthetic problems. Consequently, we can use skin grafts, pedicled flaps, free flaps, and tissue expansion for the reconstruction of this area. Compared with other reconstruction techniques, tissue expansion is advantageous in that it enables the maintenance of a color and texture similar to that of the adjacent tissue. However, the conventional method of tissue expansion has been reported to lead to an unnatural cervicomental angle and to the deformity of adjacent structures. We have therefore made efforts to prevent these problems through the use of several operative procedures. Methods: Forty-one patients with lower facial and cervical scars underwent tissue expansion. The tissue expansion was performed using a rectangular-shaped Nagosil$^{(R)}$ tissue expansion device. On insertion of the tissue expander, the intermediate area of superficial fat layer was dissected and then the tissue expander was inserted to make a flap that was as thin as possible. In advancement of the flap, a capsule-formed by the tissue expander-was used for the interrupted fixed suture of the flap to the fascia of the platysma muscle of the neck. This procedure was performed multiple times and also performed between the flap and the periosteum of the mandible, such that the tension was removed during the suture of the flap margin. Finally, the patients were fitted with a Jobst$^{(R)}$ facial garment in order to stabilize the operation site at least twelve months. Results: The most prevalent location of the scar was the cheek (15 cases), followed by the chin in 14 cases and the neck in 12 cases. The mean size of scar was $55.7{\pm}39.4cm^2$. Conclusions: Using our procedures, we have experienced no significant deformities and have also achieved a more natural cervicomental angle in the patients.

Effects of Immobilized Bipolar Interface Formed by Multivalent and Large Molecular Ions on Electrodialytic Water Splitting at Cation-Exchange Membrane Surface (양이온교환막 표면의 전기투석 물분해에서 다가의 큰 이온성분자에 의해 형성된 고정층 바이폴라 계면의 영향)

  • Seung-Hyeon Moon;Moon-Sung Kang;Yong-Jin Choi
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.143-153
    • /
    • 2003
  • The effects of bipolar interface formed on the surface of cation-exchange membrane on water splitting phenomena were investigated. Results showed that the formation of immobilized bipolar interface resulted in significant water splitting during electrodialysis. In particular, the immobilized bipolar interface was easily created on the cation-exchange membrane surface in the electrodialytic systems where multivalent cations served as an electrolyte. Multivalent cations with low solubility product resulted in violent water splitting because they were easily precipitated on the membrane surface in hydroxide form. Therefore, the bipolar interface consisting of H- and OH-affinity groups were formed on the membrane-solution interface. Apparently, water splitting was largely activated with the help of strong electric fields generated between the metal hydroxide layer and fixed charge groups on the membrane surface. Likewise, the accumulation of large molecular counter ions on the membrane surface led to the formation of a fixed bipolar structure that could cause significant water splitting in the over-limiting current region. Therefore, the prevention of the immobilization of bipolar interface on the membrane surface is very essential in improving the process efficiency in a high-current operation.