The Service Operation Strategy of Internet Shopping Mall by User Segmentation Market Typology

  • Jeong, Won-Kil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제15권1호
    • /
    • pp.11-20
    • /
    • 2004
  • The purpose of this paper was to reveal Service Operation Strategy for the Internet shopping mall based on the types of internet users' market segmentation focus on the internet shopping behavior and e-service quality. In this paper, we examined internet shopping behavior and internet service quality factor depend on the types of internet users' group empirically. The empirical study result identifies the main decision factor depend on the types of internet users' group. On the basis of these result, Service Operation Strategy for the internet shopping mall has been suggested.

  • PDF

확장된 동작 영역을 갖는 3상 전압원 PWM 컨버터의 최적 제어 (Optimal Control of a Three-Phase Voltage-Source PWM Converter with an Expanded Operation Region)

  • 민동기;안성찬;현동석;최종률
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.156-164
    • /
    • 1998
  • 3상 전압원 PWM 컨버터의 동작 영역을 동기 좌표계의 전류 벡터 평면에서 구분하고 그 특징을 설명하였다. 그 중 감역률 영역에서는 주어진 부하에 해당하는 입력 전류를 단위 역률로 제어하는 경우, 입력 전류는 왜곡되고 DC 링크 전압에는 맥동과 제어 오차가 발생하게 되어 주어진 부하 조건에서는 좋은 제어 성과를 얻을 수 없다. 본 논문에서는 이러한 문제점을 해결하는 최적 전류 벡터를 선정하는 방법을 제안하였다. 최적 전류 벡터의 선정으로 입력 전류를 가능한 최대 역률로서 정현적으로 제어하는 동시에 안정한 DC 링크 전압을 제어할 수 있게 하여 3상 전압원 PWM 컨버터의 동작 영역을 확장시킬 수 있다. 제안된 제어 방법을 실험을 통하여 증명하였다.

중규모 태양광발전시스템 장기 실증운전 평가 (The long-term operating evaluation of the grid connected photovoltaic system)

  • 김의환;안교상;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

A GORENSTEIN HOMOLOGICAL CHARACTERIZATION OF KRULL DOMAINS

  • Shiqi Xing;Xiaolei Zhang
    • 대한수학회보
    • /
    • 제61권3호
    • /
    • pp.735-744
    • /
    • 2024
  • In this note, we shed new light on Krull domains from the point view of Gorenstein homological algebra. By using the so-called w-operation, we show that an integral domain R is Krull if and only if for any nonzero proper w-ideal I, the Gorenstein global dimension of the w-factor ring (R/I)w is zero. Further, we obtain that an integral domain R is Dedekind if and only if for any nonzero proper ideal I, the Gorenstein global dimension of the factor ring R/I is zero.

플라우 및 로터리 작업 시 농업용 관리기의 엔진 부하율 분석 (Analysis of Engine Load Factor for Agricultural Cultivator during Plow and Rotary Tillage Operation)

  • 이시언;김택진;김용주;임류갑;김완수
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권2호
    • /
    • pp.31-39
    • /
    • 2023
  • The aim of this study was to measure and analyze engine load factor (LF) according to working conditions (operation type and gear stage) of small agricultural multi-purpose cultivator to estimate the emission of air pollutants. To calculate LF, a torque sensor capable of collecting torque and rotational speed was installed on the engine output shaft and DAQ was used to collect data. A field test was conducted with major operation of a cultivator and tillage operations (plow tillage and rotary tillage). Engine power was calculated using engine torque and rotational speed and LF was calculated using real-time power and rated power. In addition, unified LF was calculated using the weight for each operation and the average LF for each operation. As a result, average LF values at 1.87 and 3.10 km/h by plow tillage were 0.50 and 0.69, respectively. Average LF values at 1.87 and 3.10 km/h by rotary tillage were 0.70 and 0.78, respectively. Furthermore, unified LF calculated in consideration of the weight factor showed a value of 0.65, which was 135% higher than the conventional LF (0.48). Results of this study could be used as basic information for realizing LF values in the field of agricultural machinery.

부하역률 제약조건을 고려한 최적 급전 알고리즘 (The Optimal Power Flow Algorithm Considering Load Power Factor Limits)

  • 김광욱;조종만;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.494-499
    • /
    • 2004
  • This paper presents to compute the power economic dispatch, an optimal power flow (OPF) computation algorithm, considering the load power factor limits constraint in developed. Efficient reactive power planning enhances economic operation as well as system security. Accordingly, an adequate level of power factor limits for the load busesshould be evaluated for economic operation. In this paper, the ranges of acceptable load power factors are portrayed as bandwidths of load power factor expressed as a function of load level. The load power factor limits are included and described into the OPF's objective function. The method Proposed is applied to IEEE 26 bus system.

농작업에 따른 78 kW급 농업용 트랙터 엔진 부하율 분석 (Analysis of Engine Load Factor for a 78 kW Class Agricultural Tractor According to Agricultural Operations)

  • 백승민;김완수;백승윤;전현호;이대현;김형권;김용주
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권1호
    • /
    • pp.16-25
    • /
    • 2022
  • The purpose of this study was to calculate and analyze the engine load factor of major agricultural operations using a 78 kW class agricultural tractor for estimating the emission of air pollutants and greenhouse. Engine load data were collected using controller area network (CAN) communication. Main agricultural operations were selected as plow tillage (PT), rotary tillage (RT), baler operation (BO), loader operation (LO), driving on soil (DS), and driving on concrete (DC). The engine power was calculated using the measured engine load data. A weight factor was applied to load factor for considering usage ratio according to agricultural operations. Weight factors for different agricultural operations were calculated to be 27.4%, 32.9%, 17.5%, 7.7%, 4.5%, and 10.0% for PT, RT, BO, LO, DS, and DC, respectively. As a result of the field test, load factors were 0.74, 0.93, 0.41, 0.23, 0.27, and 0.21 for PT, RT, BO, LO, DS, and DC, respectively. The engine load factor was the highest for RT. Finally, as a result of applying the weight factor for usage ratio of agricultural operations, the integrated engine load factor was estimated to be 0.63, which was about 1.31 times higher than the conventional applied load factor of 0.48. In future studies, we plan to analyze the engine load factor by considering various horsepower and working conditions of the tractor.

혈우병 환아에서의 구강외과 수술 마취관리 -증례 보고- (Anesthetic Management of the Oral Surgery in a Child with Hemophilia A - A case report -)

  • 박창주;이종호;염광원;김현정
    • 대한치과마취과학회지
    • /
    • 제2권1호
    • /
    • pp.27-32
    • /
    • 2002
  • Hemophilia A is the most common congenital bleeding disorder, which is sex-linked disease, caused by a deficiency of clotting factor VIII. We experienced a case of alveolorrhaphy using iliac bone graft under general anesthesia for the correction of bilateral cleft alveolus in 10-year-old boy with hemophilia A. Factor VIII activity in this patient was 0.7%, on the severely deficient level, and aPTT was 100 seconds. Just before operation, he received 1,750 units of factor VIII intravenously for loading dose. After we confirmed his factor VIII activity improved to 95% and aPTT to 38.4 seconds, operation was begun. No more transfusion was needed during the operation. In his postoperative care, he received 50 units/kg a 12 hours for 3 days and 30 units/kg a 12 days for 2 days. His factor VIII activity was maintained at 57-139% during his hospitalization. He was discharged without any anesthetic complication. So we report this successful case of anesthetic management for the oral surgery in a child with hemophilia A.

  • PDF

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰 (A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System)

  • 김재언;조성현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.