• Title/Summary/Keyword: Operation Problem

Search Result 3,648, Processing Time 0.035 seconds

EPS Gesture Signal Recognition using Deep Learning Model (심층 학습 모델을 이용한 EPS 동작 신호의 인식)

  • Lee, Yu ra;Kim, Soo Hyung;Kim, Young Chul;Na, In Seop
    • Smart Media Journal
    • /
    • v.5 no.3
    • /
    • pp.35-41
    • /
    • 2016
  • In this paper, we propose hand-gesture signal recognition based on EPS(Electronic Potential Sensor) using Deep learning model. Extracted signals which from Electronic field based sensor, EPS have much of the noise, so it must remove in pre-processing. After the noise are removed with filter using frequency feature, the signals are reconstructed with dimensional transformation to overcome limit which have just one-dimension feature with voltage value for using convolution operation. Then, the reconstructed signal data is finally classified and recognized using multiple learning layers model based on deep learning. Since the statistical model based on probability is sensitive to initial parameters, the result can change after training in modeling phase. Deep learning model can overcome this problem because of several layers in training phase. In experiment, we used two different deep learning structures, Convolutional neural networks and Recurrent Neural Network and compared with statistical model algorithm with four kinds of gestures. The recognition result of method using convolutional neural network is better than other algorithms in EPS gesture signal recognition.

A zero-voltage zero-current switching power conversion system for fuel cell (영전압 영전류 스위칭을 이용한 연료전지용 전력변환시스템)

  • Son, Gyoung-Jong;Song, Sung-Geun;Moon, Chae-Joo;Kim, Kwang-Heon;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.385-394
    • /
    • 2006
  • The application areas of traditional push-pull converters are limited because the voltage stress of switches is high (twice of the input voltage). But the push - pull converter topology is suitable for unregulated low-voltage to high-voltage power conversion such as the fuel cell. This paper presents a novel power converter structure that is very suitable for the DC/DC converter in fuel cell systems. Based on this structure, a ZVS- ZCS push-pull converter is proposed. The switches of the proposed push-pull converter can operate under ZVS or ZCS condition with the help of a new passive clamping circuit. The passive clamping techniques solves the voltage overshoot problem. Because the buck converter circuit operates at twice the synchronous switching frequency of the push-pull converter, the peak current in the current-fed inductor and transformer is reduced. The operation principle of the proposed converter is analyzed and verified by simulations and experimental results. A 1 kW DC/DC converter was implemented with DSP TMS320F2812, from which experimental results have shown that efficiency improvement and surge suppression can be achieved effectively.

The development and operation characteristics analysis of PCS applied PV Output Senseless (POS) MPPT (PV Output Senseless (POS) MPPT 제어법이 적용된 단상 PCS 개발 및 운전특성 분석)

  • Lee, Seok-Ju;Park, Hae-Yong;Kim, Gyeong-Hun;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.226-227
    • /
    • 2007
  • The purpose of this study for photovoltaic (PV) generation system is to keep the output power of photovoltaic cells maximized under any weather conditions. In a conventional MPPT (Maximum Power Point Tracking) control method, both voltage and current coming out from PV array have to be fedback. Thus, the system has a complex structure, and may fail to track MPP of PV array when unexpected weather conditions happen. This paper proposes a novel PV Output Senseless (POS) control method to solve the mentioned problem. The main advantage of this method is that the current flowing into load is the only one considerable factor. In case of a huge PV generation system, it can be operated much more safely than the conventional system. To verify this theory, results that compare and analyze the simulated data with experimental data under real weather condition of the manufactured PV generation system are shown in this paper. Authors vividly states that this theory uses constant resistors and variable resistors of DC-DC converter in PV system. Authors emphasize that it is a very useful method to maximize power from PV cells to load with only the feedback of load current. Authors also emphasize that this theory is applicable in case of the PCS in PV power generation system.

  • PDF

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

A Novel PV Tracking System Control Considering the Power Loss with Change of Insolation (일사량 변화에 다른 전력손실을 고려한 새로운 태양광 추적 시스템 제어)

  • Park, Ki-Tae;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.89-99
    • /
    • 2008
  • In this paper proposes a novel tacking algorithm regarding the power loss when operating a tracking system for a rapidly changing insolation to improve the power of PV hacking system. The tracking system of sensor method used in a conventional PV power station is unable to exactly track a sun position when lacking in the intensity of radiation and has the problem is malfunction of tracking system by a rapidly changing climatic. The tracking system of program method spends too much energy on the unnecessary operation of tracking system because that is unable to adapt itself to a outside factor of climatic environment. In case of tracking an azimuth and altitude of the sun in realtime, therefore, the actual PV power is less increasing than the power of tracking system fixed a specific position. To reduce the power loss, this pap proposes a novel control algorithm of the tracking system. Also, this paper is analyzed efficiency of traditional solar tracking method and proposed method, prove validity of proposed algorithm through demonstrable study.

A Study on the Decision Process for Adoption of Enterprise Endpoint Security solutions (기업용 Endpoint 보안솔루션 도입을 위한 의사결정 프로세스에 대한 연구)

  • Moon, Heoungkeun;Roh, Yonghun;Park, Sungsik
    • Journal of Information Technology and Architecture
    • /
    • v.11 no.2
    • /
    • pp.143-155
    • /
    • 2014
  • In recent years, domestic electronics, banking, electricity, services, manufacturing, pharmaceutical, corporate type and malicious hackers is corporate security through the accident occurred and the resulting loss of corporate information and the damage each year is steadily increasing. Many companies have responded to domestic business activities and to protect critical information related to laptops, smart phones, tablets, and introduced a variety of Endpoint security solutions within. However, being introduced to senselessly Endpoint security solution across the over-budget, with the same features and performance, such as conflicts and problems arise, resulting in additional maintenance costs, in an effort to resolve the conflict in the operational security of the IT department's new difficulty in becoming. Here is the introduction and operation of these Endpoint security solutions in order to solve the problem on employees's PC into the center of the information security governance based on Endpoint security solution to provide the process for determining the solutions presented.

Research on Protocol Conversion Gateway based on IEEE1815.1 (IEEE 1815.1 기반 이기종 프로토콜 변환 게이트웨이 기술 연구)

  • Lee, Seokjun;Kwon, Sungmoon;Shon, Taeshik;Park, Sungwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1201-1209
    • /
    • 2016
  • While the legacy electric grid evolving into the smart grid, various communication standards have been used for interoperability between many components. In this situation, the needs emerged for protocol conversion and mapping method for connecting the outside components to the operation center. In this paper, according to the surge of IEC 61850-based substation automation, we studied the protocol conversion gateway for linking legacy DNP3-based control center and IEC 61850-based substation automation. This paper is based on the IEEE 1815.1 standard for the protocol mapping. We suggested the direction of development the gateway and developed prototype for evaluate the proposed gateway. Also, we bring up a security problem and give a solution.

The extension of marine lantern protocol for Dual LED marine lantern control system (이중 LED 등명기 제어 시스템을 위한 확장된 해상 등명기 프로토콜)

  • Ye, Seong-Hyeon;Kim, Bum-Khon;Park, Jeong-Seon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.445-451
    • /
    • 2014
  • Dual LED lantern, which is composed of two light sources in one lantern, can be utilized as an auxiliary light source when the main light source is in trouble. Nevertheless, there are no way to obtain status information of the system and control the light source if the current domestic standard protocol is applied, since the standards for dual LED lantern are not defined yet. Regarding to this problem, we suggested expanded lantern protocol for management system of dual LED lantern based on current domestic standard. Also, we confirmed the normal operation of dual LED lantern after implementing suggested protocol on the developed management system. Control system suggested and implemented in this study is tested not only its function of controlling and acquiring the operating status of dual LED lantern, but also its capability to utilize as a control system of currently used LED lanterns.

A Study on Prediction Reputation System Improvement for Prevention of SPIT (SPIT 차단을 위한 예측 평판도 기법 개선에 대한 연구)

  • Bae, Kwang-yong;Jo, Hwa;Yoon, Oh-jun;Jang, Sung-jin;Shin, Yongtae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1568-1576
    • /
    • 2015
  • This paper proposes a prediction reputation system for the anti-SPIT solution in real-time VoIP environment. Increased accuracy of the determination as to whether spam or not by deriving a threshold based on SPIT presence in the existing paper. The existing schemes need to get the user's feedback and/or have experienced the time delay and overload as session initiates due to real-time operation. To solve these problems, the proposed scheme predicts the reputation through the statistical analysis based on the period of session initiation of each caller and the call duration of each receiver. As per the second mentioned problem, this scheme performs the prediction before session initiation, therefore, it's proper for real-time VoIP environment.