• Title/Summary/Keyword: Operation Condition

Search Result 4,090, Processing Time 0.029 seconds

On-line Condition Monitoring of Thermal Accelerating Aged Transformer by Capacitive Sensor (전기용량 센서를 이용한 가속 열 열화 변압기의 온라인 상태진단)

  • Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.82-84
    • /
    • 2005
  • In a transformer, thermal stress is the most influential parameter affecting the aging behavior of insulation system. The aging behavior of insulation system in transformer is determined mainly by the thermal conditions inside the transformer. The thermal stress on the insulation system may occur from operation in a high temperature caused by overloading or local overheating. Thus, this paper investigated the condition monitoring of insulation condition in thermally accelerated aged transformer oils by in-situ sensor. The condition of aged samples was investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. Results from the experiments are presented in this paper.

  • PDF

The Optimum Shape of Taper HTS Current Lead Having Partial Current Sharing Region (일부 전류분류 영역을 갖는 테이퍼 형상 전류도입선의 최적 형상에 대한 연구)

  • 허광수;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.185-189
    • /
    • 2003
  • The purpose of this study is to obtain the optimal operating condition of conduction cooled taper shape high-temperature superconductor (HTS) current lead operated in current sharing mode. In our previous study, we discovered that the optimal operating condition of constant cross-section area HTS current lead is in the current sharing state, and in optimal condition, the temperature gradient at warm end is not zero. The analysis result of taper HTS current lead is quiet similar to the constant area HTS current lead. The minimum dissipation of taper HTS current lead is not influenced by taper angle, however the optimal operation condition is varied with taper angle.

  • PDF

A Study on the Operational Environment of Signalling System (신호시스템 운용환경에 관한 연구)

  • 정의진;이종우;황종규
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.164-171
    • /
    • 2000
  • To determine operational requirement, the environmental condition for an equipment must be investigated, and to certify equipment's normalized operation, appropriate test must be carried out under the considered environmental condition. The actual environmental conditions to which equipment is likely to be exposed are normally complex and will comprise a number of environmental factors and corresponding parameters, When defining the environmental conditions for a certain application it is, therefore, necessary to list the factors involved and select the appropriate severity. For the preparation to determine operational requirement, environmental condition of equipment is investigated. The environmental condition is structured in two separate such as requirements, guidance and test specifications. For the first step, environmental requirements are considered

  • PDF

The Development of Network-based Telemetry System for Railway Catenary Inspection (전차선로 검측을 위한 네트워크 기반 델레메트리 시스템 개발)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Park, Hyun-Jun;Choi, Won-Seok;Kim, Eung-Kwon;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.478-479
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed. In this paper, we proposed network-based telemetry system for condition monitoring in railway and acquired data from any kind of sensor in catenary line and structure at high voltage. This development gives the solution for online condition monitoring in railway. To check the validity of our approach in terms of application, we realized network-based telemetry System.

  • PDF

Relationship between Contact Resistance and Tribological Behavior in Boundary Lubrication (경계윤활에서 접촉 저항과 트라이볼로지 특성의 상관 관계에 관한 연구)

  • 이홍철;김대은
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.381-388
    • /
    • 2000
  • Boundary lubrication condition arises in most lubricated systems, especially during motion reversals and start up phase of operation. In this work electric contact resistance variations with respect to sliding conditions under lubrication is investigated. The motivation was to improve the understanding of the contact condition in the boundary lubrication regime. It is shown that electrical contact resistance is sensitive to sliding speed and surface condition of the specimens. Also, phenomena such as run-in during the initial phase of sliding and lubricant pile up near the sliding pin could be observed. The results of this work will aid in better understanding of the metal to metal contact condition in lubricated systems.

AN ARTIFICIAL NEURAL NETWORK MODEL FOR THE CONDITION RATING OF BRIDGES

  • Jaeho Lee;Kamal Sanmugarasa;Michael Blumenstein
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.533-538
    • /
    • 2005
  • An outline of an Artificial Neural Network (ANN) model for bridge condition rating and the results of a pilot study are presented in this paper. Most BMS implementation systems involve an extensive range of data collection to operate accurately. It takes many years to effectively implement a BMS using existing methodologies. This is due to unmatched data requirements. Such problems can be overcome by adopting the ANN model presented in this paper. The objective of the proposed model is to predict bridge condition ratings using historical bridge inspection data for effective BMS operation.

  • PDF

Chatter control and tool condition monitoring of turning processes using sound pressure (음압을 이용한 선삭공정에서의 채터제어 및 공구 상태감시)

  • Lee, S.I.;Chung, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.50-57
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstations to provide the required intelligence of the expert. This paper deals with condition monitoring for chatter, tool wear and breakage during turning operation. To develop economic sensing and identiffication methods for turning processes, sound pressure measurement and digital signal processing technique were proposed. We suppressed chatter by stability control methodology, which was studied through manipulation of spindle speeds regarding to chatter frequencies. It was shown that tool wear and fracture were identified and to be estimated by using the wear indices. The validity of the proposed system was confirmed through the large number of cutting tests.

  • PDF

A Study on the Efficient Operation of VTS in Inchon (인천항 VTS의 효율적인 운영방안에 관한 연구)

  • 김상환;박진수
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10b
    • /
    • pp.11-25
    • /
    • 1998
  • Many Countries have made efforts to assist ships navigate accurately , safely and expeditiously for the safety control against increasing marine traffic , in their coastal waters. However, they are exposed in spite of these efforts,to risks of casulaties and marine polluation caused by traffic congestion when ships are navigating through waterways approaches to ports or harbors and in narrow fairways. Therefore, efficient control of VTS in Port is necessary nowadays to provide ships with necessary service , which interacts with shipping and organize the flow of traffic so as to maximize the efficiency of the port or harbor while minimizing the risk of accident and environmental pollution. Even though the navigation condition of ships is very inferior compared to other ports in Korea, such as the big difference between the ebb and flood tide, the frequent fog, the narrow fairway , the density of navigation traffic in Inchon Port is high and transportation quantity of dangerous cargoe increases gradually. In cosideration of the characteristics of natural circumstance and traffic circumstance the VTS established newly in Inchon port have to operate efficiently. The purpose of this study is to help efficient operation of VTS in Inchon port by accomplishing both the literature research and questionnaire survey. Questionnaire survey was read to the VTS personnel in Inchon Port and customer familiar to Inchon Port such as ship navigators, pilots, shipping companies and so on. Most of ship navigators who occupy half of the respondents are Korean Officer who had responded while they were calling at Inchon port. The conclusions and recommendations includes ; First, the service area should be extended over Designated area to provide the vessel with navigational assistance service regarding the information of traffic congestion area, fishing boat and small ship's activities. Second, the types of information service to be offered are ship's movement and weather condition inthe vicinity of the port and state of fairway in the approaching channel to thte fairway. Third, VTS personnel should be upgraded by the on-the-job training and continuous simulation training as well as supplement of the qualified personnel for VTS operation. Fourth , the Harbor Master System to be introduced for safe navigation and efficient port operation.

  • PDF

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Study on Optimization of Operation in household Fuel Cell System (가정용 연료전지 시스템의 요금 분석을 통한 최적 운전 방법 검토)

  • Park, Deaheum;Cha, Kwangseok;Jo, Hokyoo;Jung, Younguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.598-603
    • /
    • 2012
  • Despite the high efficiency and eco-friendly of Household Fuel Cell System it has hardly obtained popularity mainly due to its high prices. In order to encourage use of the system prices and operational expenses need to become economical. In this study, optimization through simulation was conducted to find out the optimal operational condition. As a result of simulation the system is operated with DSS operation from 5 O'clock to 19 O'clock for 14 hours at the constant output of 0.4kW to maximize reduction of energy rate. this DSS operation condition can reduce 200,000 won of energy rates in 35 pyoung apartment for a year. And, we can know that starting time of DSS operation don't effect to energy rates through the simulation. Furthermore, the household fuel cell system with the rated output of 1kW should be reduced to 0.4 - 0.6kW which can promote installation of household Fuel Cell System. Now, the household fuel cell system don't have been used widely due to economical efficiency. but, in the near future, Fuel Cell will be used to household by decrease of LNG price caused by development of shale gas.