• 제목/요약/키워드: Operating time

검색결과 5,648건 처리시간 0.038초

근해역 시험집광기용 통합운용 프로그램 및 시뮬레이터 개발 (Development of Integrated Operating Program for Inshore Test Miner and its Simulator)

  • 이도경;윤석민;박성재;여태경;홍섭;김학경;김상봉
    • 한국해양공학회지
    • /
    • 제23권4호
    • /
    • pp.78-84
    • /
    • 2009
  • This paper presents development results of integrated operating program and its simulator for an inshore test miner. The inshore test miner drives on the seabed and collects manganese nodules. For operating the test miner, integrated operating program (IOP) is needed for remote control and monitor of the miner in real-time. However, it is hard to develop the practical IOP for the test miner system, because the system is big, expensive, and unique. So a simulator was developed as a test substitute in order to save time and to reduce cost. Using test results of the simulator, the IOP of the test miner was developed. The developed IOP consists of remote program, host program, monitoring program and database program. The operating program was developed using PXI and Labview of NI. The experimental results are presented to show the applicability of the developed program.

CMMS(Computerized Maintenance Management System)의 실 시간적인 CBMS(Condition Based Maintenance System) 연구 (Development of CMMS for the real-time CBMS)

  • 박주식;박재현;강경식;이광배
    • 대한안전경영과학회지
    • /
    • 제2권4호
    • /
    • pp.1-8
    • /
    • 2000
  • Equipment and machine of industrial plant are give effect to mechanical-stress of many working-stop or long time operating. Therefore, to be old and decrepit of every king of equipment. As long time operating equipment period into increase conservation and of repair equipment time is efficacious necessity of utility factor gradually that of productivity of diminution and complete equipment expense of increase. Conservation at special skill working and necessity is that will effectually and complete a period prevention management diagnosis can conservation point at issues at in advance.

  • PDF

가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구 (A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System)

  • 윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;정성원;김재현;이근준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

전압품질이 저압 전기기기 운전에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.33-35
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

나프타분해플랜트의 부탄추출공정에서 부탄증기의 연속누출에 의한 증기운 폭발사고의 영향평가 (The Consequence Analysis for Unconfined Vapor Cloud Explosion Accident by the Continuous Release of Butane Vapor in the Debutanizing Process of Naphtha Cracking Plant)

  • 손민일;이헌창;장서일;김태옥
    • 대한안전경영과학회지
    • /
    • 제2권4호
    • /
    • pp.33-43
    • /
    • 2000
  • The consequence analysis for the unconfined vapor cloud explosion(UVCE) accident by the continuous release of butane vapor was performed and effects of process parameters on consequences were analyzed in standard conditions. For the case of continuous release(87.8 kg/s) of butane vapor at 8 m elevated height in the debutanizing process of tile naphtha cracking plant operating at 877 kPa & 346.75 K, we found that combustion ranges of dispersed vapor estimated by HMP model were 11.2~120.2 m and overpressures estimated by TNT equivalency model at 200 m were about 37.35~55.1 kPa. Also, overpressures estimated by Model UVCE I based on advective travel time to $X_{LFL}$ were smaller than those estimated by Model UVCE IIbased on real travel time between $X_{UFL}$ and $X_{LFL}$. At the same time, damage intensities at 200 m and effect ranges by overpressure could be predicted. Furthermore, simulation results showed that effects of operating pressures on consequences were larger than those of operating temperatures and results of accidents were increased with increasing operating pressures. At this time, sensitivities of overpressures for UVCE accident by the continuous release were about 5 kPa/atm.

  • PDF

보일러 고온요소의 수명 감시시스템 소프트웨어 개발 (Development of On-line Life Monitoring System Software for High-temperature Components of Power Boilers)

  • 윤필기;정동관;윤기봉
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1999
  • Nondestructive inspection and accompanying life analysis based on fracture mechanics were the major conventional methods for evaluating remaining life of critical high temperature components in power plants. By using these conventional methods, it has been difficult to perform in-service inspection for life prediction. Also, quantitative damage evaluation due to unexpected abrupt changes in operating temperature was almost impossible. Thus, many efforts have been made for evaluating remaining life during operation of the plants and predicting real-time life usage values based on the shape of structures, operating history, and material properties. In this study, a core software for on-line life monitoring system which carries out real-time life evaluation of a critical component in power boiler(high temperature steam headers) is developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperature/stress transfer Green functions derived for the specific headers and by counting transient cycles. The major benefits of the developed software lie in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF

MSR_FSB_FREQ 제어를 이용한 윈도우 운영체제에 실시간 처리 방법 (Real-time Processing Method for Windows OS Using MSR_FSB_FREQ Control)

  • 김종진;이상길;이철훈
    • 한국멀티미디어학회논문지
    • /
    • 제24권1호
    • /
    • pp.95-105
    • /
    • 2021
  • In the case of laptops and tablet PC's that replace desktop, it uses the Windows operating system to provide various functions depending on operating system dependency, the Windows operating system does not support real-time processing because it uses multi-level feedback queue scheduling that extends round-robin scheduling. Also, since the initial value of Local APIC Counter can not be obtained from the Windows 8, the real-time processing function provided through the existing RTiK does not work. In this paper, we calculate Local APIC Counter value by using MSR_FSB_FREQ register to support real-time processing function on tablet PC's. We designed and implemented RTiK+, which provides real-time processing function to guarantee the periodicity by calculating the operation time of accurate timer. In order to verify and evaluate the performance of the implemented the RTiK+, the period was measured by using the Read Time-Stamp Counter(RDTSC) instruction and it was confirmed that it operates normally at 1ms and 0.1ms period.

주파수 평활화 기법을 이용한 전력 관리 알고리즘 (A Power-Aware Scheduling Algorithm by Setting Smoothing Frequencies)

  • 권혁성;안병철
    • 전자공학회논문지CI
    • /
    • 제45권1호
    • /
    • pp.78-85
    • /
    • 2008
  • 대부분의 전력 관리 기법에 대한 연구는 동작 주파수나 동작 전압을 변화 시켜 시스템의 가용성을 증가시키는데 집중되었다. 이 방법은 전력소모를 줄이기 위해 구동 주파수를 수시로 변경하므로 실 시스템의 성능을 저하 시킨다. 소비 전력을 줄이기 위한 다른 방법은 구동 주파수의 개수를 제한하거나 실행 시간 동안 전체 주파수를 완만하게 관리하여 시스템의 성능을 높이는 것이다. 허나 기존 연구는 실시간 응용 프로그램에는 적합하지 않다. 본 논문에서는 실시간 시스템에서 소비 전력의 손실을 줄이고 시스템의 성능을 향상시키기 위해 구동 주파수 레벨의 할당 방법과 주파수 평활화 기법을 이용한 전력 관리 기법을 제안한다. 이 기법은 연속적인 주파수 간격에서 알고리즘이 예측한 주파수를 양자화된 주파수로 매핑한다. 이러한 주파수 평활화 기법은 좁은 주파수 대역에서 잦은 주파수 변경으로 발생한 시스템의 오버헤드를 줄일 수 있다. 매핑된 주파수는 넓은 주파수 간격에서 주파수 불일치로 발생하는 전력소모를 줄일 수 있다. 모의실험을 통하여 제안한 알고리즘이 기존의 CC RT-DVS 기법에 비해 최대 40%, 평균 15% 정도 소비 전력을 줄일 수 있었다.

주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안 (Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile)

  • 박상훈;여명석;유미혜;이유지;정웅준;김광우
    • 한국주거학회논문집
    • /
    • 제23권2호
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.