• Title/Summary/Keyword: Operating Status

Search Result 954, Processing Time 0.034 seconds

Parameter Estimation by OE model of DC-DC Converter System for Operating Status Diagnosis

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.206-210
    • /
    • 2004
  • This paper deals with a parameter estimation of the DC-DC converter system for its diagnosis. Especially, we present the results of parameter estimation for the DC-DC converter model by the system identification method. The parameter estimation for the DC-DC converter system aims at the diagnosis of its operating status. For the operating status diagnosis of the DC-DC converter system, we assume that the DC-DC converter system is an equivalent model of the Buck converter and estimate the main parameter for on-line diagnosis. In addition, for verification of an estimated parameter, we compare a bode plot of the estimated system transfer function and measurement results of the HP4194 instrument. It is a control system analyzer for system transfer function measurement. Our results confirm that the main parameter for diagnosis of the DC-DC converter system can be estimated by the system identification method and that the aging status of the system can be predicted by these results on operating status.

An Investigation of the Pump Operating Characteristics as a Novel Control Index for LVAD Control

  • Choi Seongjin;Boston J. Robert;Antaki James F.
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.100-108
    • /
    • 2005
  • This work presents a novel control index to regulate the pump speed of an axial flow blood pump for the left ventricular assist device (LVAD). The control index is based on the characterization of pump operating conditions such as normal or suction status. The pump operating characteristics reveal that a certain pulsatility relationship between the pump pressure difference and the pump flow is a unique index to identify the pump operating status under the diverse pump operating environments.

An Adaptive Dispatching Architecture for Constructing a Factory Operating System of Semiconductor Fabrication : Focused on Machines with Setup Times (반도체 Fab의 생산운영시스템 구축을 위한 상황적응형 디스패칭 방법론 : 공정전환시간이 있는 장비를 중심으로)

  • Jeong, Keun-Chae
    • IE interfaces
    • /
    • v.22 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • In this paper, we propose a dispatching algorithm for constructing a Factory Operating System (FOS) which can operate semiconductor fabrication factories more efficiently and effectively. We first define ten dispatching criteria and propose two methods to apply the defined dispatching criteria sequentially and simultaneously (i.e. fixed dispatching architecture). However the fixed type methods cannot apply the criteria adaptively by considering changes in the semiconductor fabrication factories. To overcome this type of weakness, an adaptive dispatching architecture is proposed for applying the dispatching criteria dynamically based on the factory status. The status can be determined by combining evaluation results from the following three status criteria; target movement, workload balance, and utilization rate. Results from the shop floor in past few periods showed that the proposed methodology gives a good performance with respect to the productivity, workload balance, and machine utilization. We can expect that the proposed adaptive dispatching architecture will be used as a useful tool for operating semiconductor fabrication factories more efficiently and effectively.

The Study on Operating Status and Activation of Air Force Libraries (공군 병영도서관 운영 현황과 활성화 방안)

  • Sung, Eun-Jeong;Hong, Jae-Hyun
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.26 no.1
    • /
    • pp.77-100
    • /
    • 2015
  • Air Force library performs the functions of a library with respect to a specific group of Air Force. However, the development of Air Force library is beginning step, its facilities and services are not meet expectations. The analysis of operating status for entire Air Force libraries is so far not attempted. Focusing on this point, this study analysed for the first time evaluation regarding the overall operating status and activation of Air Force libraries at the levels of wing, group and squadron. The questionnaire was consisted of a total of 45 questions. The questionnaire was distributed to 101 Air Force libraries registered in currently August 2014. I was received the reply from 81 out of 101 Air Force libraries, but the responses of 4 libraries were poor, and analyzed the total 77 library responses excluding them. As the results of the analysis, this paper identified operational status and perception of activation of Air Force libraries as a whole, and pointed out the problems that have been identified regarding the operation of these libraries. Furthermore, this paper suggested concretely activation plan for the development of Air Force libraries.

A Case Study on the Companies Involved in Work and Learning Dual System at the Textile Clothing Sector in Daegu (대구지역의 섬유·의복 분야 일학습병행제 참여기업 사례연구)

  • Cho, Hyunjin
    • Journal of the Korean Society of Costume
    • /
    • v.67 no.4
    • /
    • pp.116-130
    • /
    • 2017
  • The aim of this study is to investigate the general status, operating status, and the satisfaction level of participating textile-clothing companies involved in the Work and Learning Dual System in Daegu. The general status and operating status of the participating companies are as follows. As of March 2016, 34 of the 43 companies in Daegu participated in this survey, and they were divided into three areas of textile: weaving, dyeing & finishing, and apparel manufacturing. The breakdown is as follows: 14 dyeing & finishing companies (41.2%), 13 apparel manufacturing companies (38.2%), and 7 textile weaving companies (23.6%). The results of the survey showed that 91.2% of the companies decided to participate in the system to cultivate their employees into experts in the field. The satisfaction rate of the theoretical education and training institutions was 3.88 out of 5 points. In particular, the satisfaction rate of the textile weaving companies was as high as 4.29, and the satisfaction level of the dyeing & finishing companies was higher than the average of 3.71. The overall satisfaction rate for the work-related paradigm was 3.97 out of 5 points. The results of this survey can be used to conclude that the Work and Learning Dual System is operating as it was intended to be by the government.

Irregular Sound Detection using the K-means Algorithm (K-means 알고리듬을 이용한 비정상 사운드 검출)

  • Chong Ui-pil;Lee Jae-yeal;Cho Sang-jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.1
    • /
    • pp.23-26
    • /
    • 2005
  • This paper describes the algorithm for deciding the status of the operating machines in the power plants. It is very important to decide whether the status of the operating machines is good or not in the industry to protect the accidents of machines and improve the operation efficiency of the plants. There are two steps to analyze the status of the running machines. First, we extract the features from the input original data. Second, we classify those features into normal/abnormal condition of the machines using the wavelet transform and the input RMS vector through the K-means algorithm. In this paper we developed the algorithm to detect the fault operation using the K-means method from the sound of the operating machines.

  • PDF

Development of Operating Program for EECU Test Bench

  • Kang, Myoungcheol;Kho, Seonghee;Ki, Jayoung
    • International Journal of Aerospace System Engineering
    • /
    • v.1 no.1
    • /
    • pp.10-15
    • /
    • 2014
  • This study presents technical description of the operating program development that operates the test bench for functional test of EECU. The test bench is capable of testing, simulation and adjustment of the EECU software using the operating program. The test bench is for the Development Project of the EECU platform for FADEC system. The operating program is consists of 3 modules which are the test bench operating module, cockpit simulator module and SILS module. The operating module mainly carries out the EECU test with manual operation and operating scenarios. Also that record and process the test data. The cockpit simulator module is capable of implementation of virtual cockpit control input and engine status display. The SILS module can simulate engine and EECU operation in software environment.

Development of an Intelligent Power Plant Operating State Monitoring System (발전소 설비 운영상태 지능감시 시스템 개발)

  • Hong, Chang-Ho;Kim, Seok-Hyun;Lee, Seung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • For safe and stable operations of power plants, it is essential to monitor closely crucial measurement values related to power plant trips. In this paper, an intelligent power plant operating state monitoring technique enabling the operating crew member to monitor conveniently the status of the important measurement values and to perceive almost instantly the significance of the implications of those measurement values is developed. The proposed technique is called a "POST(Plant Operating State Tracking) Chart" technique and provides the foundations in developing an intelligent and integrated power plant operating state monitoring support system called the "P-OASIS"(Plant Operation Assessment and Support Intelligent System). The P-OASIS is applied to a thermal power plant of 500[MW] capacity and exhibited impressive performances.

A study on the development of multi-task operating system for industrial robot controller (산업용 로보트 제어기의 multi task 운영체계 개발에 관한 연구)

  • 장성석;조영인;김수종;정창범;이인옥
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.497-500
    • /
    • 1988
  • The multi-task operating system called HRMTOS (HUNDAI Robot Multi-task Operating System) was developed for concurrent execution. HRMTOS consists of condition interpreter, queue constructor, task scheduler. Condition interpreter checks the status and condition of request, queue constructor makes queue according to the checked result by condition interpreter, and task scheduler finds the task that will be urgently executed by priority of queue after pending the current excuting task. HRMTOS could execute teaching, playback, monitoring function of multi-robot and could be used more effectively than other robot controllers.

  • PDF

Operating Status and Activation of Ecological Learning Facilities in Korea (국내 생태학습시설의 운영현황 고찰 및 시사점)

  • Kim, Kwon;Eum, Jeong-Hee;Rho, Paikho
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.487-501
    • /
    • 2016
  • This study aims to establish basic data of operating status for ecological learning facilities in Korea, investigate their characteristics for operating methods, and present proposals for the efficient operation and management of ecological learning facilities. For this purpose, a list of ecological learning facilities in Korea was established and 50 facilities were surveyed about the current status regarding the operation and management. Based on the survey, operation form, interpreter and volunteer, visitor, budget and revenue, promotion method, and other items were analyzed. Concerning the operating forms, most of the facilities were direct-operated facilities by government, and they are operating mainly by officials. Visitors are mostly families on weekends, while kindergarten children are main visitors during weekdays. Most facilities have higher proportion of visitors nationwide, and they get information mainly from websites operated by facilities and related organization. The annual operating budget and revenue depend on the facility size and operating forms, and the direct-operated facilities by government use higher budget compared to commission-operated ones. For the efficient operation of ecological learning, expert with specialized knowledge should participate in the operation, and intuitive and informative websites should be established and continually managed. In addition, it is necessary to support revenue of by national and local governments and to secure external funding network like local companies and donation.