• 제목/요약/키워드: Operating Rate

검색결과 3,304건 처리시간 0.035초

이젝터를 이용한 다관식 열교환기 파울링 자동제거장치의 구동특성에 관한 실험적 연구 (An Experimental Study of Operating Characteristics on Fouling Auto Removal Apparatus of Multi Pass Type Heat Exchanger using Ejector)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.63-69
    • /
    • 2009
  • The experiment was performed to check operating characteristics of fouling auto removal apparatus for multi pass type heat exchanger using ejector. The results showed as following. The ejector suction flow rate increased with the head of operating pump of ejector. Proper suction flow rate showed $7.2{\sim}10.2m^3/h$ for ball collection in case of pump head 35~50m. The head of ejector outlet pipe is below 4.1m in case of 40m, the head of operating pump of ejector to confirm ejector suction flow rate 8.4m3/h. Lattice space of ball separator is allowed 6~10.3mm in ranges of ball diameter are 15~25mm and when mass flow of cooling water is 3.0m/sec. Average of passing time of balls is 1.2~2.8sec depend on the velocity of flow and the size of balls.

  • PDF

전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로- (The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II))

  • 배기서;이태상;노덕길;홍영기
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

어린이집 운영상 어려움의 예측 요인 탐색: 원장보고를 중심으로 (Exploring Predictors Affecting Difficulties in Operating Childcare Centers: Focusing on Directors' Reports)

  • 신나리;김경화;윤현정;노필순;송지은
    • 한국보육지원학회지
    • /
    • 제18권4호
    • /
    • pp.17-36
    • /
    • 2022
  • Objective: The purpose of this study is to examine the relationship between structural and process difficulties experienced by childcare center directors in operating childcare centers and to explore characteristics of childcare centers that affect the path. Methods: The participants were 309 childcare center directors, and data were collected through a mobile survey method. Descriptive statistics and SEM were implemented using SPSS and AMOS. Results: Unsupported childcare centers and capacity aggravated structural difficulties in operation of childcare centers, while the number of enrolled children and the enrollment rate reduced such difficulties that were reported by directors. In the case of labor cost supported centers and childcare centers with a high enrollment rate reported a high level of process difficulties. Because the effect of structural difficulties on process difficulties were significant, the indirect influences of structural difficulties that mediated the influences of general background characteristics on process difficulties were also significant. Conclusion/Implications: This study shows that difficulties in operating childcare centers could be considered in terms of structure and process aspects. This study is also meaningful in that it suggests that the characteristics of individual childcare centers should be emphasized in a customized way to alleviate such difficulties.

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구 (A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System)

  • 윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

가열수 온도에 의한 저온진공건조 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of Low Temperature Vacuum Drying by Hot Water Temperature)

  • 김경근;최순열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.588-594
    • /
    • 2001
  • The aim of this paper is to develop the low temperature vacuum dryer, with low initial investments and operating costs, easy operating method and trouble-free operation Usally operations just below atmospheric pressure, as with direct dryers, but some are built for vacuum operation with pressure as low 50 mmHg abs. The lowers the boiling point to $39^{\circ}C$ The experimental data of quantitative analysis for using practically were obtained by the constant drying rate period and reducing drying rate period according to the temperature of hot water which is the experimental parameters of present experiment. As the results, it took about 20 hours for material to reach about 18% of the final moisture content is order to store products for a long time about 450% of the early moisture content at the beginning of drying and maximum drying rate comes to about 0.30 kg/m2hr at about 350% of the moisture content.

  • PDF

생체 건조용 대형 저온진공건조기의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of the Large Low Temperature Vacuum Dryer for Biological Drying)

  • 김경근;성부용;정한식;최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.427-434
    • /
    • 2000
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects; (1) much energy loss happens due to the discharge of hot air during the drying process, (2) control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3) high temperature of foods in drying process brings about the production of low-grade drying products. Vacuum drying takes advantage of energy saving and mass production because it reduces the drying time by increasing the drying rate under low temperature condition. The aim of this paper is to develop the low temperature vacum dryer, with low initial investments and operating costs, easy operating method and trouble-free operation.

  • PDF

Study on the Coupled Effects of Process Parameters on Silicon Growth Using Chemical Vapor Deposition

  • Ramadan, Zaher;Ko, Dong Kuk;Im, Ik-Tae
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.115-121
    • /
    • 2019
  • Response surface methodology (RSM) is used to investigate the complex coupling effects of different operating parameters on silicon growth rate in planetary CVD reactor. Based on the computational fluid dynamics (CFD) model, an accurate RSM model is obtained to predict the growth rate with different parameters, including temperature, pressure, rotation speed of the wafer, and the mole fraction of dichlorosilane (DCS). Analysis of variance is used to estimate the contributions of process parameters and their interactions. Among the four operating parameters that have been studied, the influences of susceptor temperature and the operating pressure were the most significant factors that affect silicon growth rate, followed by the mole fraction of DCS. The influence of wafer rotation is the least. The validation tests show that the results of silicon deposition rate obtained from the regression model are in good agreement with those from CFD model and the maximum deviations is 2.15%.

직접에탄올 연료전지의 운전조건에 관한 연구 (A Study on an Operating Conditions for the Direct Ethanol Fuel Cell)

  • 김영춘;구본국;장문국;지학배;한상보;박재윤
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2076-2082
    • /
    • 2011
  • The goal of this paper is to find an operating conditions of the single direct ethanol fuel cell such as the cell temperature, and flow rates of ethanol and oxygen. To investigate the output characteristics, the electrical current increased from 0[A] with interval of 0.001[A] every 2[s], and the cell voltage was increased until the voltage became 0.05[V]. Related to the effect of the cell temperature, the output characteristics both voltage and power were increased upto 80[$^{\circ}C$] according to the increase of the current density, but those were decreased over that temperature. In addition, the optimal flow rate of ethanol in anode was identified as of 2[mL/min] due to the dependence of generation rate such as the hydrogen ion and electron. And the flow rate of oxygen in cathode was desirable to about 300[sccm/min], it might be affected by the chemical reaction rate of the water formation among hydrogen ion, electron, and oxygen. Consequently, the fundamental conditions were identified in this work, and it will be carried out to find the best conditions of membrane by the effect of the plasma surface treatment, and the effect of other catalysts except for a platinum.

Reliability Evaluation of a Microgrid Considering Its Operating Condition

  • Xu, Xufeng;Mitra, Joydeep;Wang, Tingting;Mu, Longhua
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.47-54
    • /
    • 2016
  • Microgrids offer several reliability benefits, such as the improvement of load-point reliability and the opportunity for reliability-differentiated services. The primary goal of this work is to investigate the impacts of operating condition on the reliability index for microgrid system. It relies on a component failure rate model which quantifies the relationship between component failure rate and state variables. Some parameters involved are characterized by subjective uncertainty. Thus, fuzzy numbers are introduced to represent such parameters, and an optimization model based on Fuzzy Chance Constrained Programming (FCCP) is established for reliability index calculation. In addition, we present a hybrid algorithm which combines scenario enumeration and fuzzy simulation as a solution tool. The simulations in a microgrid test system show that reliability indices without considering operating condition can often prove to be optimistic. We also investigate two groups of situations, which include the different penetration levels of microsource and different confidence levels. The results support the necessity of considering operating condition for achieving accurate reliability evaluation.