• Title/Summary/Keyword: Operating

Search Result 25,726, Processing Time 0.044 seconds

The Statistical Analysis of Operating Life Characteristic on Poler Transformers(I) (전력용 변압기 운전수명 특성의 통계적 분석(I))

  • Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Kim, Moon-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1885-1887
    • /
    • 1996
  • Power transformers are the most important facilities in the substation of electrical power, yet they do not have the efficient operating life characteristics which are the important elements of repairing and maintenance in regional conditions. This paper describes the statistical analysis of operating conditions and troubles on transformers for the operating life assessment using Statistical Analysis System programs, Hazard method and Weibull distributions. We analyze transformers in several methods, and compares correlation relationship of operating life and troubles. Therefore, this study will be the useful basic operating life prediction technique of power transformers in the future.

  • PDF

An Investigation on the Torque Converter Characteristics at Various Operating Conditions (작동 조건 변화에 대한 토크 컨버터의 성능 특성 분석)

  • Jang, Wook-Jin;Lee, Chin-Won;Lim, Won-Sik;Park, Yeong-Il;Lee, Jang-Moo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.678-683
    • /
    • 2000
  • The one-dimensional performance model of a torque converter has been widely used to analyze and predict the performance and dynamic behavior of a torque converter. But this model doesn't include the information of the operating fluid properties. Therefore, to precisely predict dynamic performance of a torque converter, the effect of operating conditions must be considered through experimental coefficients such as friction loss coefficient and shock loss coefficient. And these coefficients cannot be achieved without experiments or internal flow analysis. In this study, the effects of varying material properties of operating fluid according to various operating temperatures are clarified with flow analysis of a torque converter. And these results are verified by comparing with those of performance experiment.

  • PDF

Development of the Coil Spring Design Program for Spring Operating Mechanism (스프링조작기 개발을 위한 코일 스프링 설계 프로그램 개발)

  • Kim, Min Soo;Jun, Chul Woong;Sohn, Jeong Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.281-285
    • /
    • 2017
  • Since the performance of the spring operating mechanism for a circuit breaker mainly depends on the dynamic behavior and mass of the coil spring, its dynamic analysis is required to evaluate the performance of the spring operating mechanism. In this study, a coil spring design program is developed for the spring operating mechanism. An experimental approach is used to find the variables satisfying the design constraints' requirements. The coil spring is formed by using a lumped mass spring model. This program offers reference data for the design of coil springs and for the spring operating mechanism.

A Study on Recognition of Operating Condition for Hydraulic Driving Members (유압구동 부재의 작동조건 식별에 관한 연구)

  • 조연상;류미라;김동호;박흥식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.136-142
    • /
    • 2003
  • The morphological analysis of wear debris can provide early a failure diagnosis in lubricated moving system. It can be effective to analyze operating conditions of oil-lubricated tribological system with shape characteristics of wear debris in a lubricant. But, in order to predict and recognize an operating condition of lubricated machine, it is needed to analyze and to identify shape characteristics of wear debris. Therefore, If the morphological characteristics of wear debris are recognized by computer image analysis using the neural network algorithm, it is possible to recognize operating condition of hydraulic driving members. In this study, wear debris in the lubricating oil are extracted by membrane filter (0.45 ${\mu}{\textrm}{m}$), and the quantitative values of shape parameters of wear debris are calculated by the digital image processing. This shape parameters are studied and identified by the artificial neural network algorithm. The result of study could be applied to prediction and to recognition of the operating condition of hydraulic driving members in lubricated machine systems.

A Study on the Improvement of KC Certification Scheme of Electrical Appliances for Global Competence (글로벌 경쟁력 강화를 위한 전기용품 안전인증제도(KC) 개선에 관한 연구)

  • Kwon, Jin-Wook;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.27-33
    • /
    • 2017
  • Electrical product safety certification is for public safety. Korea electrical safety certification (KC) is being tested and certified on the base of Korean electrical appliance safety act and KC scheme. There are operating system and Electrical safety standards in the KC scheme. KC' operating system was adapted from japan operating system of Japan certification scheme. But KC certification' electrical safety standard was adapted from IEC standards of IECEE CB scheme. So There are many problems such as difference of version between KC standards and IEC standards, discrepancy between operating system and standards. Therefore, This paper analyzed the reason of discrepancy and proposed the improved KC certification operating system in order to reduce cost and to save time in the procedure of issuing KC approval for public safety in using electrical products and also for global competence.

Experimental Study of the Effect of the Reservoir on CPL Operation (CPL의 운전에 미치는 레저버의 영향에 대한 실험적 연구)

  • Hwang, Hyung-Jin;Joung, Wuk-Chul;Lee, Jin-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2033-2038
    • /
    • 2008
  • The CPLs(capillary pumped loops) are two phase heat transfer devices which enable active control of operating temperature of heat absorbing elements(or evaporators). Although the CPLs gain increasing interests as promising heat transfer devices for future missions such as spacecraft and commercial applications, their intrinsic complexity in operating principles makes the widespread use of these devices difficult. The key element and main cause of this complexity in operating principles is the two phase hydrodynamic accumulator or reservoir which controls the saturation state of the remaining loop and, particularly for the CPLs, it is separated from the evaporator. Thus, in this study, the operating characteristics of the CPL is investigated experimentally and theoretically. Mainly focusing on the role of reservoir the thermodynamic operating principle is examined first and the experimentally obtained steady state and transient state operating characteristics are discussed in detail.

  • PDF

Decomposition of the Most Generalized Triadic Operating Policy Using its Corresponding Expected Busy Period (Busy Period 기대값을 사용하여 가장 일반화된 삼변수 운용방침의 분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.162-168
    • /
    • 2011
  • The most generalized form of the triadic operating policy for a controllable M/G/I queueing model is analyzed to obtain fundamental relations among the other forms of operating policies based on its corresponding expected busy period. Since it consists of three decision variables N, T and D, it could be possible to decompose into the simple, the dyadic and other forms of the triadic operating policies. The procedures to decompose the most generalized triadic policy into other forms of operating policies could provide a general methodology to identify each element associated with it.

Embedded Operating System using the Single Address Space(SAS) Architecture (Single Address Space(SAS) Architecture를 이용한 Embedded Operating System)

  • An, Gwang-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.608-611
    • /
    • 2003
  • A large part of the embedded system, compared with the PC, have low performance CPU and small memory. So the embedded operating system fits the condition of that hardware system. A Single Address Space (SAS) OS has the operating system and all applications in the single address space. The SAS architecture enhances sharing and co-operation, because addresses have a unique interpretation. Thus, pointer-based date structures can be directly communicated and shared between programs at any time, and can be stored directly on storage. The key point of the SAS OS on the embedded system is the low overhead inter-action between programs in process and usage. So SAS OS can be ported on the low performance CPU. In this paper, we design the SAS OS (named emNOS, Embedded Network Operating System) on the ARMTTDMI processor. Finally we show the benefits of the SAS OS on the embedded system.

  • PDF

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • v.4 no.3
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.

The Effects of the Change of Operating Income Disclosure Policy under K-IFRS - Evidence from KOSDAQ Market - (K-IFRS 이후 영업이익 공시정책의 변화에 대한 연구 - 코스닥 시장을 중심으로 -)

  • Baek, Jeong-Han;Choi, Jong-Seo
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.167-187
    • /
    • 2014
  • While Korean GAAP had detailed regulations for the measurement and disclosure of operating income in the past, K-IFRS did not provide specific rules for operating income until 2011. Some firms that adopted K-IFRS before 2011 did not disclose or calculated operating income in an inconsistent manner although operating income is usually considered as one of the core information items to assess firm valuation. Inconsistency in firms' treatment of operating income invoked much criticism from diverse users of financial statement. The Korean Accounting Institute (KAI hereafter) revised the K-IFRS rules relevant to operating income in September 2010 in response to the voices raised by the business community, whereby the operating income number is allowed to be calculated in conformity with the previous K-GAAP. This study was motivated by the revision of K-IFRS and aims to provide a clue on the validity of such policy decision. To achieve the research objective, we test the relative value relevance of the alternative operating income numbers under K-IFRS versus K-GAAP. Our main findings are as follows. The value relevance of operating income reported before K-IFRS is proved to be higher than after K-IFRS. K-IFRS operating income adjusted to the previous K-GAAP has greater explanatory power for market values relative to one calculated under the K-IFRS regime. In an additional analysis, the sample was decomposed according to whether the operating income under K-IFRS is greater than under K-GAAP. The difference in the value relevance of K-IFRS versus K-GAAP operating income is significant only in the subsample consisting of firms which reports higher operating income under K-IFRS compared to K-GAAP. Also, the firms which would have reported negative operating income on a consecutive basis are more likely to have chosen K-IFRS, resulting in higher numbers than otherwise. It is likely that firms facing the threat of delisting due to consecutive operating loss reporting are more likely to have adopted K-IFRS disclosure rules by which they could report higher operating income numbers. To sum up, these results corroborate the limitation inherent in the K-IFRS regarding operating income disclosures. This paper suggests that the recent revision of K-IFRS implemented by KAI is likely to mitigate some of afore-mentioned limitations effectively.

  • PDF