• Title/Summary/Keyword: Operating

Search Result 25,611, Processing Time 0.044 seconds

A Model for Determining Optimal Operating Time of Aircrafts Attacking Multiple Targets (다수 표적을 공격하는 편대항공기의 최적작전시간 결정 모형)

  • Kim Yong-Bok;Min Gye-Ryo
    • Journal of the military operations research society of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-73
    • /
    • 1992
  • Up to the present, the operating time has been studied on only a single aircraft attacking a single target or multiple targets under enemy threats. This study is to determine optimal operating time and appropriate size of aircrafts attacking multiple targets. Measures of mission effectiveness is defined through derivation of the probability of the various events associated with operating. By using these measures, the expected benefit of operating and the expected cost of operating are generated as a function of time. To formulate operating time determination model, the expected gain of operating is defined as the difference between the expected benefit of operating and the expected cost of operating. The model can be used to determine optimal operating time which maximizes the expected gain of operating, and can be used as the basis for determining the appropriate size of aircrafts.

  • PDF

Study on the Performance Characteristics of the Solar Hybrid System with Heat Pump Operating Temperature during Winter Season (겨울철 열펌프 작동온도에 따른 태양열 하이브리드 시스템의 성능특성에 관한 연구)

  • Kim, Won-Seok;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.821-827
    • /
    • 2010
  • Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season has performed by using an experimental test. The system performance and operating characteristics with the heat pump operating temperature, hour and load condition were investigated and analyzed. As a result, the hot water temperature was significantly affected by the heat pump operating temperature at the morning(time 1) and noon(time 2). However, hot water temperature was set by the radiation quality and collecting operation hour at the afternoon(time 3). In addition to the solar fraction was decreased for the high heat pump operating temperature because the heat pump operated with a long operating time and short operating period.

Analysis of Core Interventions of Operating Room using Nursing Intervention Classification (NIC간호중재분류체계를 이용한 수술실 핵심간호중재분석)

  • Lee, Yoon-Young;Park, Kwang-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.3
    • /
    • pp.361-372
    • /
    • 2002
  • Purpose : The purpose of study was to identify to analysis of core nursing interventions performed by Operating Room nurses. Method : The subjects of the study were arbitrarily selected nurses(n=104) working in Operating Room. The period for data collection was 15 days from July, 15, 2002 to July, 30. 2002. The instrument for study was 486 Nursing Interventions Classification developed by McClosky & Bulechek(2000) and was translated into Korean. In 486 nursing interventions, 57 nursing interventions were selected by more than half of 47 professional nurses group of Operating Room. 57 nursing interventions were used as a secondary questionnaire. In the secondary questionnaire, labels and definitions of all 57 interventions were listed. The collected data were self reported by Operating Room nurses. The data were analysed with SPSS program. Result : In 57 nursing interventions, the 'Behavior' domain was the most frequently used. Core interventions of Operating Room were performed several times a day by more than 50% of Operating Room nurses. Core interventions of Operating Room were 16 Core interventions, 7 classes, 5 domains. In the core interventions, the 'Physiological:Complex' domain was the most frequently used. Core interventions of Operating Room were Surgical Preperation, Infection Control:Intraoperative, Surgical Precautions, Fall Prevention, Documentation, Surgical Assistance, Environmental Management:Safety, Skin Surveillance, Physical Restraint, Pressure Ulcer Prevention, Environmental Management:Comfort, Infection Protection, Presence, Emotional Support, Specimen Management, Shift Report. Conclusion : Core interventions of Operating Room have implications for nursing care practice, nursing education, nursing research, and nursing information system in Operating Room.

  • PDF

Analysis of a Maintenance·Repair Service Center Model Operating under Alternating Complementary Dyadic Policies (상호보완적인 이변수 운영정책이 교대로 적용되는 정비서비스센터 모형분석)

  • Rhee, Hahn-Kyou
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.58-65
    • /
    • 2017
  • Different from general operating policies applied for various waiting line situations, two complementary dyadic operating policies are applied alternatingly to a single server maintenance service center model. That is, either of the two dyadic Min (N, T) or Max (N, T) policy is applied to operate such center first and the other operating policy should be applied later, and then the same sequence of both operating policies is followed repeatedly. This operating policy is denoted by the Minimax (N, T) policy. Purpose: Because of the newly introduced operating policy, important system characteristics of the considered service center model such as the expected busy and idle periods, the expected number of customers in the service center and so on should be derived to provide necessary information for determination of the optimal operating policy. Methods: Based on concepts of the newly introduced Minimax (N, T) policy, all necessary system characteristics should be redefined and then derived by constructing appropriate relations between complementary two dyadic operating policies. Results: Desired system characteristics are obtained successfully using simple procedures developed by utilizing peculiar structure of the Minimax (N, T) policy. Conclusion: Applying Minimax (N, T) operating policy is equivalent to applying the simple N and T operating policies alternatingly.

Analysis of a Controllable Queueing Model Operating under the Alternating Operating Policies (변동 운용방침이 적용되는 조정가능한 대기모형 분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.81-90
    • /
    • 2016
  • Different from general operating policies to be applied for controllable queueing models, two of three well-known simple N, T and D operating policies are applied alternatingly to the single server controllable queueing models, so called alternating (NT), (ND) and (TD) policies. For example, the alternating (ND) operating policy is defined as the busy period is initiated by the simple N operating policy first, then the next busy period is initiated by the simple D operating policy and repeats the same sequence after that continuously. Because of newly designed operating policies, important system characteristic such as the expected busy and idle periods, the expected busy cycle, the expected number of customers in the system and so on should be redefined. That is, the expected busy and idle periods are redefined as the sum of the corresponding expected busy periods and idle periods initiated by both one of the two simple operating policies and the remaining simple operating policy, respectively. The expected number of customers in the system is represented by the weighted or pooled average of both expected number of customers in the system when the predetermined two simple operating policies are applied in sequence repeatedly. In particular, the expected number of customers in the system could be used to derive the expected waiting time in the queue or system by applying the famous Little's formulas. Most of such system characteristics derived would play important roles to construct the total cost functions per unit time for determination of the optimal operating policies by defining appropriate cost elements to operate the desired queueing systems.

Rational Operation through International Case Studies on SO Operating Channel (직접사용채널의 해외사례 검토를 통한 합리적 운영 방안)

  • Kim, Hee-Kyung;Cha, Young-Ran
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.93-107
    • /
    • 2011
  • SO and Satellite Broadcaster can operate SO Operating channel in Korea. However, the Broadcasting act does not specify the direction of what purpose the SO operating channel would be operated for. Accordingly, SO and Satellite Broadcaster do not operate SO operating channel or use it as profit channel when operating. In this respect, the cases of U.S. and Japan have been studied to determine how SO operating channel should be operated to make it desirable. In the U.S., it is being used in various ways such as profit channel, multi-access channel and access channel. In Japan, it is mainly focused on the role as local channel, being coordinated with local governments to form public opinion on local news and issues or to announce local events. In Korea, SO is operating local channel similar to the one in Japan rather than SO operating channel, while Satellite Broadcasting is operating SO operating channel mainly for its profits. As SO operating channel is operated on the basis of the broadcasters' expediency without clear stipulation in Korea, we will need to seek the plan to use it for public interests by discussing more the status and operation of SO operating channel.

Reducing the Disposal of Unused Blood in the Operating Room (수술장에서의 혈액 폐기율 감소)

  • Cho, Moon Su;Lee, Yeoung Sook;Yu, Il Me
    • Quality Improvement in Health Care
    • /
    • v.3 no.2
    • /
    • pp.70-85
    • /
    • 1997
  • Background : 6.1% of red blood cells and whole blood issued to the operating room was not transfused to the patients and discarded in Seoul National University Hospital in 1994. Objectives : We planned to set up an effective management program of blood in the operating room and we investigated whether this program could reduce the disposal rate of blood. Methods : We made a guideline of blood management in the operating room through a workshop. The guideline was revised after a preliminary application. The revised guideline was applied for 5 months from May to September in 1996. The disposal rate was compared before and after the installation of the new program. Results : 5,336 units of blood were issued to the operating room for 5 months. Disposal rate of red blood cells and whole blood was markedly reduced from 6.2% in May to 2.1% in September(p<0.05). The average disposal rate was 3.7% during the five months. Conclusion : We were able to reduce the disposal of unused blood in the operating room through the development and the application of a new blood management program.

  • PDF

A Study on the Area Composition of the Operating Unit After Remodeling (수술부 리모델링을 통한 공간구성 변화에 관한 연구)

  • Kim, Khilchae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.

The Analysis of Railroad Operating Costs in Korean Railroad Projects

  • SungWook KANG;DongHee KIM;GyuBae KIM
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Purpose: A railroad project is a complex system with large construction costs in the initial stage and ongoing operating costs over its lifecycle. Current railroad projects tend to be based on construction options, which leads to huge deficiencies in operating costs. This phenomenon results from a lack of appropriate tools to accurately estimate a railroad project's lifecycle costs. This study attempts to analyze the major components of railroad operating costs and to propose a decision-making system for analyzing the long-term lifecycle costs of railroad projects. Research design, data and methodology: We review the literature and analyze the current status of railroad operating costs in Korea and overseas. Based on previous projects, a framework for project options and operating costs is proposed. The framework is applied to actual railroad projects to demonstrate the validity of the model. Results: Case analysis shows that our framework is comprehensive in analyzing the primary aspects of railroad operating costs and plays an effective role in choosing various railroad project options. This study points out that the railway project operates inefficiently because estimating long-term costs without reflecting specific project options causes many errors. Conclusions: A major contribution of this study is the development of an improved framework for accurately estimating operating costs and providing policymakers and engineering firms with a holistic decision support system. Detailed components in estimating operating costs of the railroad business are discussed. And we present a decision-making tool that policymakers and private businesses can use in planning the railroad business.

A study on the optimum operation scheme with operating reserve power (운전예비력의 최적운용방식에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.28 no.5
    • /
    • pp.49-55
    • /
    • 1979
  • During severe emergencies which result in insufficient generation to meet load, an automatic load shedding method considering the spinning and operating reserve can establish the optimum system operation. This paper presents methods and results of a study on the optimum operating scheme with spinning and operating reserve power in case of outage of large generator units to prevent frequency decay and continue stable operation. This study covers following three parts 1) Analysis of spinning reserve characteristics 2) Determination of operating reserve requirements 3) Development of the optimum load shedding programs By this study the optimum system operating method was recommended for reliable operation of power system.

  • PDF