• 제목/요약/키워드: Open-tube

검색결과 310건 처리시간 0.025초

임피던스 관을 이용한 흡음재의 특성 임피던스 측정: 배후조건에 따른 민감도 분석 (Impedance Tube Measurements of Sound Absorbing Materials: Sensitivity Analysis on Backing Conditions)

  • 이종화;이정권;박봉현;김병훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.888-891
    • /
    • 2001
  • Effects of backing conditions on the impedance tube measurement are investigated experimentally, by using several pairs of generally employed end conditions. The results show that the measured values are similar for most of pairs, except the case of using an open pipe condition. In addition, the random error is investigated in the viewpoint of the variation of test conditions. The multi-termination method is suggested for minimizing such a random error.

  • PDF

증기발생기용 대형 단강품의 자유단조 (Open Die Forging of the Large Steel Forgings for Steam Generator)

  • 김동권;김재철;김영득;김동영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.39-42
    • /
    • 2003
  • Steam Generator has been manufactured by welding process after partial manufacturing of various steel forgings such as shell, head and tube sheet. Usually, these steel forgings are made by open die forging process. After steel melting and ingot making, open die forging has been carried out to get a good quality which means high soundness and homogeniety of the steel forgings by using high capacity hydraulic press. This paper introduced open die forging development status of the large steel forgings which is used for the steam generator of 1,400MW next generation nuclear power plant.

  • PDF

전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석 (Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD)

  • 남기원;민준기;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.491-499
    • /
    • 2010
  • 관군은 열전달기기에서 광범위하게 사용되고 있어서 전열성능 및 압력강하 특성은 오래전부터 다양한 연구가 진행되어왔다. 기존의 관군에 관한 실험 및 해석은 대부분 25~51mm 직경의 전열관을 이용하여 Reynolds 수 $8.000{\leq}Re{\leq}30.000$ 범위에서 수행되었으나 최근에는 직경 1mm 안팎의 미세관으로 관군을 만들어 열교환기의 밀집도를 높이려는 데 관심이 많다. 본 논문에서는 이전에 다루지 않았던 관 외경 1.5mm의 관군의 전열성능을 $3.000{\leq}Re{\leq}7.000$ 범위에서 전산유체역학을 이용하여 평가하고 기존의 연구 결과들과 비교하였다. 그 결과 튜브직경이 1.5mm인 관군의 열전달계수와 압력손실계수는 $3.000{\leq}Re{\leq}7.000$ 범위에서도 기존의 Zukauskas 상관식과 최대 4.7% 차이 이내로 일치하였다. 또한 튜브의 횡방향 간격을 줄여서 각 열의 전열성능을 높일 수 있음을 확인하였다.

Numerical Study on Laser-driven In-Tube Accelerator (LITA) Performance using a Plasma Size Modeling

  • Kim, Sukyum;Toshiro Ohtani;Akihiro Sasoh;Jeung, In-Seuck;Park, Jeong--Yeol
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.320-324
    • /
    • 2004
  • Laser Propulsion is a device that generates thrust using laser energy. Laser-driven In-Tube Accelerator (LITA) has been developed at Tohoku University. LITA is a laser propulsion system that accelerates an object not in an open air but in a tube. Experiments of vertical launching and pressure measurement on the tube wall were carried out and in order to observe the initial state of plasma and blast wave, the visualization experiment was carried out using the shadowgraph method. In this study, the time variation of pressure on the tube wall is numerically simulated solving Euler equation. In order to model the laser energy, heat source function added to the frozen flow Euler equation. Plasma size from the shadowgraph images was used for the initial condition of laser energy input. For verification of the modeling, these results were compared with the previous experimental and numerical results. From these verifications, an analysis of LITA performance will be investigated.

  • PDF

연료극 지지체식 원통형 고체산화물 연료전지의 제조 및 특성 (Fabrication and Characteristics of Anode-supported Tubular Solid Oxide Fuel Cell)

  • 송근숙;송락현;임영언
    • 한국재료학회지
    • /
    • 제12권9호
    • /
    • pp.691-695
    • /
    • 2002
  • A low temperature anode-supported tubular solid oxide fuel cell was developed. The anode-supported tube was fabricated using extrusion process. Then the electrolyte layer and the cathode layer were coated onto the anode tube by slurry dipping process, subsequently. The anode tube and electrolyte were co-fired at $140^{\circ}C$, and the cathode was sintered at $1200^{\circ}C$. The thickness and gas permeability of the electrolyte depended on the number of coating and the slurry concentration. Anode-supported tube was satisfied with SOFC requirements, related to electrical conductivity, pore structure, and gas diffusion limitations. At operating temperature of $800^{\circ}C$, open circuit voltage of the cell with gastight and dense electrolyte layer was 1.1 V and the cell showed a good performance of 450 mW/$\textrm{cm}^2$.

개심수술후(Open-Heart Surgery) 환자의 교육 요구에 관한 간호원과 환자와의 비교연구 (A Comparison Study of Educational Needs Following Open-Heart Surgery Assessed by Nurses and Patients Themselves)

  • 김금순;조경숙
    • 대한간호학회지
    • /
    • 제14권2호
    • /
    • pp.12-18
    • /
    • 1984
  • The purpose of this study was to compare educational needs following open heart surgery assessed by nurses & patients themselves, Data were collected from Nov. 1983 to Jan. 1984 through administration of Questionnaire developed for this study by the researcher. The subjects were 45 patients who experienced open heart surgery and 29 nurses who taking care of these patients in chest surgery ward at Seoul National University Hospital. The Data were analyzed by T-test and One Way ANOVA according to dependent variables. The result were as follows 1. There are significant difference between educational needs, assessed by nurses and patients themselves. (p<0.05) The nurses reported higher score of educational needs than patients. 2. In comparison of content area of educational needs, there was significant difference according to respiratory care, fain, chest tube care and operation including heart function between two groups. But, there was no significant difference in diet, activity, complication, emotional care and medication between two groups. 3. The priorities in content area of educational needs rated by nurses and patients were similar.

  • PDF

액화석유가스(butane)의 대기중 누출현상에 대한 고찰 (Discussions on the Leak Phenomena of Liquid Butane in the Open Air)

  • 윤재건
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.59-62
    • /
    • 2000
  • Almost accidents related with gas have started with the leakage of LPG(Liquefied Petroleum Gas) in the open air. But experimental data of LPG leak jet are difficult to find because the safety of experiment is hard to secure and its phenomenon is not steady but transitional. This study is focused on the phenomena of injection jet of liquid butane to the open air. Simple experiment shows that only liquid butane jet in the open air is possible due to the slow vaporization because of low temperature difference between the liquid and air and low vapor pressure of liquid butane. Comparing with the water, 25~40% more liquid butane flow through the tube under the same pressure difference driving.

  • PDF

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

3개월 이하 영아의 대동맥 축착증 수술치료에 대한 임상연구 (Correction of Coarctation in Infants Less than Age 3 Months)

  • 신제균;송명근
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1139-1145
    • /
    • 1990
  • Seven infants less than age 3 months underwent patch aortoplasty and tube graft bypass for relief of coarctation of aorta. All had intractable congestive heart failure, despite aggressive medical therapy Each infant had other cardiac anomalies including patent ductus arteriosus, ventricular septal defect, atrial septal defect and congenital mitral stenosis. All patients underwent closure of the ductus arteriosus and patch angioplasty of the aorta to produce a luminal diameter of at least 15mm or tube graft interposition utilizing the Gortex tube graft diameter larger than 10mm. In 5 patients who had ventricular defect, they underwent pulmonary arterial banding. &ere was one hospital death 17 days after operation secondary to the hydronephrosis and renal failure. Hospitalization was less than 10 days after operation except one case. In 3 patients who had associated VSD, open heart surgery[VSD closure+PA debanding]was done without difficulty. Surgical repair of critical coarctation of the aorta in infants can safely be offered despite the poor preoperative condition and presence of other cardiac anomalies.

  • PDF

EFFECTS OF GEOMETRIC PARAMETERS ON NUCLEATE POOL BOILING OF SATURATED WATER IN VERTICAL ANNULI

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.271-278
    • /
    • 2009
  • Nucleate pool boiling of water in vertical annuli at atmospheric pressure has been studied experimentally and two empirical correlations have been suggested to obtain effects of geometric parameters on heat transfer. Data of the present and the previous tests range over a tube length of 0.50-0.57 m, a diameter of 16.5-34.0 mm, and an annular gap size of 3.7-44.3 mm. Through the analysis, tube bottom confinement (open or closed) has been investigated, as well. The developed correlations predict experimental data within a ${\pm}25%$ error bound. It has been identified that effects of the diameter and the length of heated tubes as well as the annular gap size should be counted into the analyses to estimate heat transfer coefficients accurately.