• Title/Summary/Keyword: Open-Phase Fault

Search Result 69, Processing Time 0.023 seconds

Detection and Classification of Open-phase Faults in PMSM Using Extended Kalman Filter and Multiple Model (확장칼만필터 및 다중모델 기반 영구자석 동기전동기 권선 개방 고장의 검출 및 분류)

  • Minwoo Kim;Junhyeong Park;Sangho Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.100-107
    • /
    • 2023
  • Open-phase fault in a Permanent Magnet Synchronous Motor (PMSM) occurs due to disconnection of phases of motor windings or inverter switch failures. When an open-phase occurs, it leads to the generation of torque ripples and vibrations in the motor, which can have a critical impact on the safety of the vehicle (including aircraft) using a PMSM as an actuator. Therefore, rapid fault detection and classification are essential. This paper proposes a classification method for detecting open-phase faults and locating fault positions in a PMSM used in aircraft applications. The proposed approach uses an Extended Kalman Filter for fault diagnosis, and it subsequently classifies faults using a Multiple Model filter.

Open Circuit Fault Diagnosis Using Stator Resistance Variation for Permanent Magnet Synchronous Motor Drives

  • Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.985-990
    • /
    • 2013
  • This paper proposes a novel fault diagnosis scheme using parameter estimation of the stator resistance, especially in the case of the open-phase faults of PMSM drives. The stator resistance of PMSMs can be estimated by the recursive least square (RLS) algorithm in real time. Fault diagnosis is achieved by analyzing the estimated stator resistance of each phase according to the fault condition. The proposed fault diagnosis scheme is implemented without any extra devices. Moreover, the estimated parameter information can be used to improve the control performance. The feasibility of the proposed fault diagnosis scheme is verified by simulation and experimental results.

Control of Open-Loop PWM Delta-Connected Motor-Drive Systems under One Phase Failure Condition

  • Sayed-Ahmed, Ahmed;Demerdash, Nabeel A.O.
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.824-836
    • /
    • 2011
  • A new fault-tolerant control topology for open-loop motor-drive systems with Delta-connected stator windings is introduced in this paper. This new control topology enables the operation of a three-phase induction machine as a two-phase machine fed by a three-phase inverter upon a failure in one of the motor phases. This topology utilizes the "open-Delta" configuration to independently control the current in each of the two remaining healthy phases. This new control technique leads to the alleviation of any torque pulsations resulting from the consequences of the asymmetrical conditions associated with this class of faults.

Fault Tolerance Operation and Characteristics Analysis of Asymmetric Six-phase Permanent Magnet Synchronous Motor According to Switch Open (비대칭 6상 영구자석 동기 전동기의 스위치 개방에 따른 특성 분석 및 고장허용운전)

  • Jun, So-Young;Hwang, Seon-Hwan;Park, Jong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1003-1008
    • /
    • 2022
  • This paper proposes a method related to fault tolerance operation and characteristic analysis of asymmetric 6-phase permanent magnet synchronous motor. In general, motor drive systems with multi-phase structures can be continuously operated despite a reduction of power and speed by using a phase changeover or control techniques according to the failures. As a result, it is widely used in industrial fields such as aviation and defense, which require high efficiency and high reliability. In this paper, the second order ripple of the electrical fundamental freuqnecy occurs in the dq-axis currents of the synchronous coordinate system through mathematical analysis according to the switch open of the dual 3-phase inverter. Therefore, the fault tolerant operation method is presented by applying the fault detection method with a constant cycle for continuous operations. The effectiveness of the proposed fault tolerance operation method is verified through the several experiments.

Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase (디지털 역결상 보호 계전기의 설계 및 제작)

  • Kim, Woo-Hyun;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

Fault Diagnosis for Induction Motor Drive System (유도 전동기 구동 시스템의 고장진단)

  • Kim, Ho-Geun;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.154-156
    • /
    • 1993
  • In this paper, fault analysis using simulation method and fault diagnosis scheme are presented for induction motor drive system. Major faults such as inverter 'a' phase open fault, inverter 'a'-'b' phase short circuit fault and inverter 'a' phase ground fault are analyzed and simulated. On-line and off-line fault diagnosis systems are proposed.

  • PDF

Fault Tolerant Control Methods for Dual Type Independent Multi-Phase BLDC Motor under the Open-Switch Fault Conditions

  • Kim, Yong-Hyu;Heo, Hong-Jun;Park, June-Ho;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.722-732
    • /
    • 2018
  • Dual type Independent multi-phase BLDC Motor (DI-BLDCM) is designed to be robust to faulty conditions of motor and drive system. Despite the efforts of the motor design, open-switch faults of DI-BLDCM drive system cause the torque ripple of the motor. This torque ripple makes unwanted sound noise and mechanical vibration of associated systems. This paper proposes four methods for compensating the torque ripple and compares the characteristics of each proposed method. All proposed methods are able to reduce the torque ripple to similar level of the healthy condition, although the motor operates in open-switch fault conditions. However, these methods have different characteristics in various fault conditions. Therefore, from the results of the comparison, the suitable method is selected for the various fault conditions. The feasibility of the proposed methods is proved by the several experimental results.

Fault Detection and Compensation Scheme of Switch Open-fault in VSI for Two-phase Excitation Drive (2상 여자 구동용 전압형 인버터의 스위치 개방고장 검출 및 보상 기법)

  • Lee, Kui-Jun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.74-80
    • /
    • 2007
  • This paper proposes the novel open-fault detection/isolation scheme of inverter switch in two-phase excited VSI. This scheme identify open-fault using voltage sensor at lower switches of each phase according to the operating mode. It has benefit of simple implementation, fast detection and robustness in the load so that stab of the system is improved. Also, at faulty mode, it minimizes faulty effect and makes possible continuous operation through the reconfiguration procedure applying four-switch operation. The validity of proposed fault detection scheme is verified by experimental results.

A Study on Remote Alarm System of Open-phase Faults based on IoT (IoT 기반의 결상사고 원격알람 시스템에 관한 연구)

  • Jeong, Hoe-Joong;Kwak, Dong-Kurl;Choi, Shin-Hyeong;Kim, Choon-Sam;Yang, Ki-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.4-6
    • /
    • 2018
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground(G) of three phase. And the open-phase detection system is configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

Algorithm for Switch Open Fault Detection of Asymmetric 6-phase PMSM Based on Stationary Reference Frame dq-axis Currents (비대칭 6상 영구자석 동기 전동기의 정지 좌표계 DQ축 전류를 이용한 스위치 개방 고장 검출 기법)

  • Lee, Won-Seok;Kim, Han-Eol;Hwang, Seon-Hwan;Lee, Ki-Chang;Park, Jong-Won
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.265-270
    • /
    • 2022
  • This paper proposes the detection algorithm for switch open fault of asymmetric 6-phase PMSM based on stationary reference frame dq-axis currents. In this paper, target motor has an asymmetric structure in which two upper three windings have an electrical phase difference of 30° and a neutral point is separated. As a result, dual 3-phase PWM inverters and the detection techniques due to open failures of switch are definitely required. In this paper, the dual dq-axis current control method is used for driving the asymmetric 6-phase PMSM and the open fault switch should be detected by using variable all pass filter and low pass filter in order to detect the current amplitude. The effectiveness and usefulness of the proposed method is verified by several experiments.