• Title/Summary/Keyword: Open plate fixation

Search Result 105, Processing Time 0.025 seconds

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate (뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술)

  • Kwon, Yu-Jin;Kim, Ji-Hoon;Hwang, Jae-Ha;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

The Result of Open Reduction and Fixation in Sternal Fracture with Displacement (흉골 전위골절에 대한 수술적 정복고정술의 결과)

  • Kim, Young-Jin;Cho, Hyun-Min
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.

Mini-open Treatment Using Plate of Clavicle Mid-shaft Fractures

  • Park, Yong-Geun;Kang, Hyunseong;Kim, Shinil;Bae, Jong-Hwan;Choi, Sungwook
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • Background: Increased frequency of comminuted clavicle mid-shaft fractures and importance of functional satisfaction through early joint exercise has resulted in higher emphasis on surgical treatments. This study aimed to evaluate the clinical radiological results of treatment of clavicle mid-shaft fractures by open reduction and internal fixation using a plate with a small incision. Methods: The subjects of this study were 80 clavicle mid-shaft fracture cases treated with internal fixation using a plate from October 2010 to July 2014. Clavicle mid-shaft fractures were internally fixated using anatomical plates or locking compression plates. Achievement of bone union, union period, and clavicle length shortening were evaluated radiologically, and clinical assessment was done by using Constant and University of California at Los Angeles (UCLA) scores. Results: All 80 cases were confirmed to have achieved bone union through radiographs with an average union period of 10.9 weeks (range: 7-18 weeks). The average clavicle length of shortening in the affected side was 1.8 mm (range: 0-17 mm). The average UCLA score and Constant score were 33.6 (range: 25-35) and 92.5 (range: 65-100), respectively. Regarding complications, four cases reported skin irritation by metal plates, and one case reported a screw insertion site fracture due to minor trauma history. Conclusions: We were able to induce successful bone union and obtain clinically satisfactory results in displaced mid-shaft fractures of the clavicle without major complications such as nonunion through treatment of internal fixation using a plate.

The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

  • Bemelman, Michael;van Baal, Mark;Yuan, Jian Zhang;Leenen, Luke
    • Journal of Chest Surgery
    • /
    • v.49 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft $f{\ddot{u}}r$ osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

Operative Treatment of Unstable Fracture of the Proximal Humerus (상완골 근위부 불안정성 골절의 수술적 치료)

  • Kim Young-Kyu;Jang Young-Hun;Kim Keon-Beom
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.198-204
    • /
    • 1998
  • Unstable fractures of the proximal humerus continue to be difficult problems for orthopaedic surgeons. The optimum treatment of these fractures has remained a matter of controversy. We analyzed the clinical results of open reduction and plate fixation underwent for patients of unstable fractures of proximal humerus after minimum 12 months follow up. The purpose of this study is to evaluate the efficacy of open reduction and rigid plate fixation. Twenty-two patients were managed with open reduction and plate fixation. Mean follow up duration was 20.6 months(range, 12 to 28 mon.). Because the age of patient as a maker of degree of osteoporosis was considered the key factor in the success of anatomic reconstruction, we divided into two groups according to age. Group A was comprised of 12 cases with younger than 50 yrs of age. Ten cases of older than 50 yrs of age were Group B. According to Neer's classification, five cases(22%) were two part fracture, 12 cases(64%) were three part fracture, and three cases(14%) were four part fracture. We used the Neer rating system for evaluating the results. In Group A, overall scores were 79.1. In Group B, overall scores were 76.8. Overall scores in two part fracture were 85, overall scores in three part fracture 78.4 and overall scores in three part fracture 68.3. We achieved excellent or good results in nine cases(75%) of Group A and seven cases(70%) of Group B. Also, we obtained excellent or good results in all cases of two part fracture, ten cases(71%) of three fracture and one case(33%) of four part fracture. The complications were three metal loosening, one avascular necrosis of humeral head, one severe stiff shoulder, one superficial wound infection and one ectopic ossification. The results were excellent or good in 16 cases(73%) out of 22 cases. In conclusion, rigid fixation and supervised early exercise would be a good option for unstable fracture of the proximal humerus.

  • PDF

Surgical Outcomes of Intra-articular Fractures of Calcaneus using AO Calcaneal Plate (관절내 종골 골절에 대해 AO 종골 금속판을 이용한 수술적 치료 결과)

  • Kim, Seong-Tek;Youn, Te-Hyun;Park, Jin-Bum;Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To evaluate the outcomes of intra-articular calcaneal fractures treated using AO calcaneal plate surgically. Materails and Methods: Total 15 cases of intra-articular calcaneal fracture that treated with open reduction and internal fixation using AO calcaneal plate were evaluated. The patients were followed over a mean period of 19.8 months. The mean age was 41.6 years. By Sanders classification, there were 2 cases of type II, 10 cases of type III, and 3 cases of type IV. We evaluated radiological outcomes by Bohler angle, Gissane angle, calcaneal hight, calcaneal width and clinical outcomes by Creighton-Nebraska health foundation score. Results: All fractures united at a mean duration of 13.3 weeks. Radiologically, the mean preoperative Bohler angle was $8.5^{\circ}$ and restored to $23.3^{\circ}$. The mean preoperative Gissane angle was $118.7^{\circ}$ and restored to $124.2^{\circ}$. The mean preoperative calcaneal hight was 30.8 mm and restored to 38.9 mm. The mean preoperative calcaneal width was 41.3 mm and restored to 35.3 mm. 10 cases had excellent and good clinical outcomes and 5 cases having fair outcome. Conculsion: In our study, open reduction and internal fixation using AO calcaneal plate showed good results with anatomical restoration of articular surface and stable fixation without late collapse.

  • PDF