• Title/Summary/Keyword: Open loop response

Search Result 92, Processing Time 0.021 seconds

Vibration Localization of Open Loop Repeated Structures (개방형 반복구조물의 진동국부화)

  • Ha, Dong-Jin;Yoo, Hong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.12
    • /
    • pp.911-917
    • /
    • 2003
  • Vibration localization characteristics of open loop repeated mistuned structures are investigated. The mistuning often creates significant response discrepancies among subcomponents of the repeated structures. As a result of the discrepancies, critical fatigue problems often occur in repeated structures. Therefore. it is of great importance to predict the vibration response of the mistuned repeated structures accurately in this Paper, a simplified model for an open-loop repeated structure is introduced and dimensionless parameters that influence the localization characteristics are identified. The effects of the parameters on the localization characteristics are investigated through numerical study.

Performance Analysis of the Optoelectronic Oscillator using the Direct Modulation Laser (레이저 직접 변조를 이용한 광전 발진기의 성능 분석)

  • Cho, Jun-Hyung;Heo, Seo-Weon;Sung, Hyuk-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2029-2036
    • /
    • 2014
  • The performance analysis of optoelectronic oscillator(OEO) based on a directly modulated semiconductor laser was theoretically achieved. First, the analysis was performed on the open response of the key components that constitute the OEO loop. Using the results, we simulated the open-loop characteristics of the OEO loop. By combining oscillation conditions of loop oscillator in addition to the open-loop magnitude and phase responses, theoretical performance analysis such as OEO's oscillation frequency, spurious tones and phase noise was successfully completed.

Vibration Localization of Open Loop Repeated Structures (개방형 반복구조물의 진동국부화)

  • 하동진;유홍희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.489-494
    • /
    • 2003
  • Vibration localization characteristics of open loop repeated structures with mistuning are investigated in this paper. Mistuning of a periodic structure often creates significant non-uniformity in vibration responses. As a result of the localization, critical fatigue problems often occur in repeated structures. Therefore, it is of great importance to predict the vibration response of the mistuned repeated structures accurately. In this paper, a simplified model for the open-loop repeated structure is introduced and dimensionless parameters which influence the localization characteristics are identified. The effects of the parameters on the localization characteristics are investigated through numerical study.

  • PDF

A Study on Miniaturization and Design Flexibility of an Elliptic-Response Open-Loop Resonator Filter (타원응답 개방 루프 공진기 필터의 소형화 및 설계 유연성에 관한 연구)

  • 안창수;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1082-1089
    • /
    • 2004
  • In this paper, miniaturization of an elliptic-response open-loop resonator filter and design flexibility using similarity transformation of the coupling matrix are proposed. Moreover, the filter with wider fractional bandwidth is designed by the proposed method. In order to verify the proposed method, three 4th-order elliptic-response open-loop resonator filters with a relative bandwidth of 4 % at the center frequency of 2.0 GHz are designed. One is realized with constant-width microstrip line resonator and the others are implemented with different-width microstrip line resonator. Compared with the former one, the latter have shown the size reduction of 13 % and 25 %, respectively. Since it may not be possible to implement the resonators with very narrow spacing for the required coupling coefficient filters with two different configurations representing same response characteristic through similarity transformation of the coupling matrix are proposed. From this design flexibility, a filter with a relative bandwidth of 8 % at the center frequency of 2.0 GHz is designed with realizable design parameters.

A Study on Position of Six-Degrees-of-Freedom of vibration Model and Orientation Decision by Adaptive Control Method (6자유도 진동모댈의 위치 및 자세결정을 위한 적응제어기법의 적용에 관한 연구)

  • Kim, J.Y.;Song, S.K.;Han, J.H.;Oh, Y.H.;Cho, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.94-101
    • /
    • 1994
  • About vibration model of Six-degrees-of-freedom(DOF), in mass load, examined results for knowing dynamic interference and response variation is as follows; In case of putting mass load upon the object, experimented results on two-degrees-of-freedom of the translation-1 direction and the rotation-1 direction at open-loop-control system, about 0.19 arcsed in input of the translation-$0.1{\mu}m$ and $0.022{\mu}m$ on input of the rotation-0.5 arcsec, the justicse of motion equation is acknowledged as confirming the appearance of the interference-$0.022{\mu}m$. In establishing calculation of transformation matrix by using analogue circuit, as simulating results that used incomplete differentiation, interference is $1.7{\times}10^{-3}$ arcsec on input of the translation-$0.1{\mu}m$ and $1.4{\times}10^{4}{\mu}m$ on input of the rotation-0.5 arcsec in open-loop-control system. Also it is $4.2{\times}10^{-4}$ arcsec on input of the translation-$0.1{\mu}m$ and $5.6{\times}10^{-5}{\mu}m$ on input of the rotation-0.5 arcesc in closed-loop-control system. As closed-loop-control system is better than open-loop-control system, equivalent accordance is confirmed on original response. Finally, fundamental validity of this theory is acknowledged.

  • PDF

HARDWARE IN THE LOOP SIMULATION OF HYBRID VEHICLE FOR OPTIMAL ENGINE OPERATION BY CVT RATIO CONTROL

  • Yeo, H.;Song, C.H.;Kim, C.S.;Kim, H.S.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.201-208
    • /
    • 2004
  • Response characteristics of the CVT system for a parallel hybrid electric vehicle (HEV) are investigated. From the experiment, CVT ratio control algorithm for the optimal engine operation is obtained. To investigate the effect of the CVT system dynamic characteristics on the HEV performance, a hardware in the loop simulation (HILS) is performed. In the HILS, hardwares of the CVT belt-pulley and hydraulic control valves are used. It is found that the engine performance by the open loop CVT ratio control shows some deviation from the OOL in spite of the RCVs open loop control ability. To improve the engine performance, a closed loop control of the CVT ratio is proposed with variable control gains depending on the shift direction and the CVT speed ratio range by considering the nonlinear characteristics of the RCV and CVT belt-pulley dynamics. The HILS results show that the engine performance is improved by the closed loop control showing the operation trajectory close to the OOL.

Active Vibration Control of Clamped Beams Using Filtered Velocity Feedback Controllers (Filtered Velocity Feedback 제어기를 이용한 양단지지보의 능동진동제어)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.447-454
    • /
    • 2011
  • This paper reports a filtered velocity feedback(FVF) controller, which is an alternative to direct velocity feedback(DVFB) controller. The instability problems due to high frequency response under DVFB can be alleviated by the suggested FVF controller. The FVF controller is designed to filter out the unstable high frequency response. The FVF controller and the dynamics of clamped beams under forces and moments are first formulated. The effects of the design parameters(cut-off frequency, gain, and damping ratio) on the stability and the performance are then investigated. The cut-off frequency should be selected not to affect the system stability. The magnitude of the open loop transfer function(OLTF) at the cut-off frequency should be small. As increasing the gain of the FVF controller, the magnitude of the OLTF is increased, so that the closed loop response can be reduced more. The enhancement of the OLTF at the cut-off frequency is reduced but the phase behavior around the cut-off frequency is distorted, as the damping ratio is increased. The control performance is finally estimated for the clamped beam. More than 10 dB reductions in velocity response can be achieved at the modal frequencies from the first to eighth modes.

Active Vibration Control of Clamped Beams using Filtered Velocity Feedback Controllers (Filtered Velocity Feedback 제어기를 이용한 양단지지보의 능동진동제어)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.264-270
    • /
    • 2011
  • This paper reports a filtered velocity feedback (FVF) controller, which is an alternative to direct velocity feedback (DVFB) controller. The instability problems due to high frequency response under DVFB can be alleviated by the suggested FVF controller. The FVF controller is designed to filter out the unstable high frequency response. The FVF controller and the dynamics of clamped beams under forces and moments are first formulated The effects of the design parameters (cut-off frequency, gain, and damping ratio) on the stability and the performance are then investigated. The cut-off frequency should be selected not to affect the system stability. The magnitude of the open loop transfer function (OLTF) at the cut-off frequency should be small. As increasing the gain of the FVF controller, the magnitude of the OLTF is increased, so that the closed loop response can be reduced more. The enhancement of the OLTF at the cut-off frequency is reduced but the phase behavior around the cut-off frequency is distorted, as the damping ratio is increased The control performance is finally estimated for the clamped beam. More than 10dB reductions in velocity response can be achieved at the modal frequencies from the first to eighth modes.

  • PDF

Handling Deflection Limit in Open-Loop-Onset-Point PIO Analysis (Open-Loop-Onset-Point PIO 해석의 변위한계)

  • Park, Sang-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • A new treatment is proposed to handle a deflection limit in the open-loop-onset-point (OLOP), which is commonly used in the prediction of pilot in-the-loop oscillation (PIO) due to a rate saturation. The new approach is motivated by the frequency response of a stand-alone actuator in that, unlike the suggestion by the original OLOP procedure, the rate limit onset is not delayed to a higher frequency by a deflection limit. Indeed, if a feedback control loop is closed, the rate limit onset can be shifted to a lower frequency since the controller tends to react with larger commands when deflection limited. The amplitude of the command at this onset frequency is combined with the deflection limit to estimate the associated gain reduction in the open-loop-onset-point in the final step of the OLOP process. The comparison of the new approach with the previous method reveals that an inaccurate optimism which can occur in the previous method is corrected by the proposed treatment.