• Title/Summary/Keyword: Open Ratios

검색결과 243건 처리시간 0.029초

Clean Stocker내 새로운 방식의 기류제어에 관한 연구(II) (Analysis of New Air Control System in Clean Stocker(II))

  • 최기한;한창우;이상룡
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1178-1186
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker. Up to now, stockers typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker. This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, in order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and experiment was also conducted using actual clean stocker for TFT-LCD manufacturers and CFDesign, was used for simulating airflow in stocker. As a result, open ratios of exits can be obtained by the analysis of static pressure regain and was verified by experiment and simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Clean Stocker내 새로운 방식의 기류제어에 관한 해석 (Analysis of New Air Control System in Clean Stocker)

  • 최기한;한창우;이상룡
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

원형 밀폐 및 개방형 돔 지붕의 풍압 스펙트럼 (Wind Pressure Spectra for Circular Closed and Open Dome Roofs)

  • 천동진;김용철;이종호;윤성원
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.69-76
    • /
    • 2020
  • Wind tunnel tests were conducted to analyze the wind fluctuating pressures on a circular closed and open dome roof with a low span rise. Two dome models with various geometric parameters (height/span ratios and open ratios) were used for fixed span rise ratio dome and wind pressure spectrum were analyzed. The applicability was examined in comparison with the spectral model proposed in the previous studies. The analysis results show that the wind pressure spectrum of open dome roof tends to increase power in the high frequency range and the second peak is found in the area different from the closed dome roof. In addition, according to the comparison analysis with the previous proposed spectral model, it was found that it is not applicable to the closed and open dome roofs with low rise ratio due to the different peak frequencies.

Investigation on hydrodynamic performance of a marine propeller in oblique flow by RANS computations

  • Yao, Jianxi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.56-69
    • /
    • 2015
  • This paper presents a numerical study on investigating on hydrodynamic characteristics of a marine propeller in oblique flow. The study is achieved by RANS simulations on an open source platform - OpenFOAM. A sliding grid approach is applied to compute the rotating motion of the propeller. Total force and moment acting on blades, as well as average force distributions in one revolution on propeller disk, are obtained for 70 cases of combinations of advance ratios and oblique angles. The computed results are compared with available experimental data and discussed.

기공닫힘부 폐쇄정도 결정을 위한 평가방법 연구 (Evaluation methods for Void Closing Behavior in Large Ingot)

  • 최익준;최호준;윤덕재;이근안;임성주
    • 소성∙가공
    • /
    • 제20권5호
    • /
    • pp.339-343
    • /
    • 2011
  • This paper presents methods for analyzing the extent of cylindrical-shaped void closure. In addition, a quantitative relationship between change in void fraction and height reduction ratio of a compressed specimen is proposed. The height reduction ratio, number of deformation steps and billet rotation were chosen as key process parameters influencing the void closing behavior, namely, the changes in void shape and size during hot open die forging of a large ingot. The extent of void closure was analyzed from microscopic observations and estimated from tensile test results. The tensile strengths of specimens with closed voids and those without were compared for various reduction ratios in height. The results confirmed that void closure occurs at reduction ratios greater than 30 %. The void closing behavior could be expressed as a hyperbolic tangent function of reduction ratio in height, number of paths, and billet rotation. The knowledge presented in this paper could be helpful for optimizing deformation paths in open die forging processes.

Cone-beam computed tomography for the assessment of root-crown ratios of the maxillary and mandibular incisors in a Korean population

  • Choi, Sung-Hwan;Kim, Jung-Suk;Kim, Cheol-Soon;Yu, Hyung-Seog;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2017
  • Objective: This retrospective, cross-sectional study aimed to establish reference data for normal crown and root lengths and the root-crown ratios (R/C ratios) for the mature maxillary and mandibular incisors in a Korean population by using cone-beam computed tomography (CBCT). Methods: We included 672 Korean patients (141 men and 531 women; mean age, $27.2{\pm}7.7years$) who underwent CBCT examinations during various dental treatments. Crown and root lengths and the R/C ratios of the maxillary and mandibular incisors were measured using CBCT data, which were analyzed to detect significant differences between demographic factors as well as sagittal and vertical skeletal or occlusal relationships. Results: Teeth of the same type in each half-arch were symmetrical. The mean R/C ratios varied from 1.1 to 1.2 for the maxillary incisors and from 1.3 to 1.4 for the mandibular incisors. Crown and root lengths were greater in men than in women, regardless of tooth type. Root lengths and R/C ratios for the mandibular incisors were significantly greater in patients with skeletal Class II malocclusion or an excessive overjet than in the other patients. The R/C ratios for the mandibular incisors were lower in patients with an open bite than in those with a normal or deep bite. Moreover, the R/C ratios for the mandibular incisors increased with age. Conclusions: The data obtained in our study can serve as reference values for crown and root lengths and the R/C ratios for the maxillary and mandibular incisors in the Korean population.

하나의 열원을 가지는 캐비티 내의 열전달 특성 (Heat Transfer Characteristics on the Cavity with One Heat Source)

  • 이용훈;배강열;정한식;정효민;이상철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.56-64
    • /
    • 2004
  • A numerical study have been performed on a cavity with one heat source by the open ratio and tilt angle. The goal of this study is to get the information for designing a solar collector absorber. semi-conductor equipment and block heater and so on. The parameters for this study is the various open ratio. and tilt angle of the cavity and Rayleigh numbers The finite volume method with SIMPLE computational algorithm are used and calculated the heat transfer in the cavity. As a result, the heat trans(or was promoted by increase of Rayliegh numbers and open ratios But, the heat transfer was not promted at lower wall of cavity because the flow pattern are very small at lower space in the cavity(Or=0.1) As the Rayleigh number is increased the mean nusselt numbers are increased at inside wall.

단선과 단락 스터브가 연결된 전송선로를 이용한 높은 분배비율을 갖는 전력 분배기 (Power Dividers for High Splitting Ratios using Transmission Line Connected with Open and Short Stubs)

  • 김영
    • 한국항행학회논문지
    • /
    • 제25권3호
    • /
    • pp.229-235
    • /
    • 2021
  • 본 논문은 단락 또는 단선 스터브가 연결된 전송선로를 이용하여 높은 분배 비율을 갖는 비대칭 전력 분배기를 구현하는 방법을 제안하였다. 제안된 방법은 2포트 전송선로 중앙에 임의의 임피던스로 변환할 수 있도록 별도의 포트를 추가한 3포트 전송선로와 단선 또는 단락 스터브가 각 포트에 병렬로 연결된 3포트 전송선로를 등가회로로 보고 회로를 해석한 것이다. 이러한 방법의 타당성을 증명하기 위해서, 분배 비율 k2 = 20 dB를 갖는 윌킨슨 전력분배기와 k2 = 17 dB를 갖는 Gysel 전력분배기를 3포트 전송선로 등가회로를 이용하여 중심주파수 1 GHz에서 설계하였으며, 전기적 특성의 실험 결과는 시뮬레이션과 잘 일치함을 확인하였다.

Temporal and spatial variation in the distribution of life history phases of Chondrus crispus (Gigartinales, Rhodophyta)

  • Garbary, David J.;Tompkins, Elizabeth;White, Katelyn;Corey, Peter;Kim, Jang-K.
    • ALGAE
    • /
    • 제26권1호
    • /
    • pp.61-71
    • /
    • 2011
  • Thirty populations of Chondrus crispus Stackhouse from Nova Scotia were collected during the years 1993 to 2011. Taken from estuaries, wave exposed open coasts, high intertidal rock pools and shallow subtidal habitats, the populations were evaluated for relative abundance of tetrasporophytic and gametophytic life history phases. Over 2,800 thalli were characterized using the resorcinol-acetal test to distinguish the kappa- and lambda-carrageenan containing fronds of gametophytes and tetrasporophytes, respectively. These populations had $77{\pm}5%$ gametophytes (mean ${\pm}95%$ confidence interval), with most populations having gametophyte : sporophyte ratios ranging from 2 : 1 to 9 : 1. No population had a dominance of tetrasporophytes, although two populations had 1 : 1 ratios. A meta-analysis of our data along with previously published accounts showed no significant changes in gametophyte dominance with respect to hypothesized gradients of wave exposure, salinity, or water depth. Significant changes occurred in ratios at five sites where replicate sampling occurred in different years. We conclude that C. crispus in Maritime Canada has a natural ratio of 3 : 1 or greater in stable conditions, and that lower ratios represent recovery from disturbance in which bare substratum is created that is subsequently colonized by carpospores from remaining gametophytic thalli.

풍동 실험을 통한 타원형 개폐식 돔 지붕의 외장재용 풍압 계수 분석 (Analysis of External Peak Pressure Coefficients for Cladding in Elliptical Retractable Dome Roof by Wind Tunnel Test)

  • 이종호;김용철;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.49-59
    • /
    • 2020
  • This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.