• Title/Summary/Keyword: Open/Short Test

Search Result 98, Processing Time 0.023 seconds

A Study on the 22.9KVY Multiground Distribution System (22.9KVY 배전방식에 관한 연구)

  • Sung Bong Byon
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.8-18
    • /
    • 1973
  • This paper is a part from the series study on the 22.9KVY multiground destribution system and its is divided into three parts as follow. A.C. Network Analyzer study on the load current flow when one phase line of the feeder is out of seroice because of cutting. A.C. Network Analyzer study on the increasing zero sequence current in the good feeders when one feeder is under fault of single phase short. Field test report of the common use of open telephone line on same poles of 22.9KVY distribution system.

  • PDF

An Extended Scan Path Architecture Based on IEEE 1149.1 (IEEE 1149.1을 이용한 확장된 스캔 경로 구조)

  • Son, U-Jeong;Yun, Tae-Jin;An, Gwang-Seon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1924-1937
    • /
    • 1996
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi- board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan paths either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using, he proposed ESP architecture, we observed to the test time is short compared with the single scan path architecture. Because the ESP architecture uses the common bus, there are not additional signals in multi-board testing. By comparing the ESP architecture with conventional one using ISCAS '85 bench mark circuit, we showed that the architecture has improved results.

  • PDF

Design and Performance Testing of a 30dVA Superconducting Generator (30kVA 초전도발전기의 설계 및 성능평가)

  • 손명환;백승규;권영길;장국렬;이언용;류강실;박도영;김용주;안종보
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.146-149
    • /
    • 1999
  • A 30kVA superconducting generator has been designed, developed and successfully tested recently. The design is based on 2-dimensional electromagnetic field analysis. The rotor has been wound with superconducting wire of Nb-Ti alloy. The stator has the air-gap type armature windings. Open-circuit test, short-circuit test and lamp load test have been conducted. The details of design program, design, machinebuilding, test results and conclusions are given in this paper.

  • PDF

A Short-term and Long-term Usability Testing of the Speech Synthesizer for the People with Visual Impairments (시각장애인용 음성합성기에 대한 장/단기 사용성 평가)

  • Lee, H.Y.;Hong, K.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • We conducted a long-term and short-term usability testing on the built-in speech synthesizer of a screen-reader for the people with visual impairments. A total of 20 persons with visual impairments participated in the short-term usability testing, and 10 of them participated in the long-term usability testing. Naturalness and clarity of the synthetic speech were evaluated by MOS scores, preference for various synthetic speeches was examined through a preference test, and the users' satisfaction level and other requirements for the synthetic speech were evaluated by open feedback. We also examined naturalness, clarity, preference, and user requirements for the synthetic speech through a long-term usability testing. Then, we compare and contrast the long-term and short-term usability testing results.

  • PDF

SHORT-PERIOD VARIABILITY SURVEY (SPVS) IN BOAO (보현산천문대 단주기변광성 탐사(SPVS)연구)

  • Jeon, Young-Beom;Kim, Seung-Lee;Park, Yoon-Ho;Park, Byeong-Gon;LeeK, Chung-Uk;Lee, Eun-Jeong;Kim, Min-Su;Lee, Kyung-Hoon
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.21-27
    • /
    • 2005
  • We have been performing a wide-field photometric monitoring program, named SPVS (Short-Period Variability Survey), at the Bohyunsan Optical Astronomy Observatory (BOAO). The observation system consists of a small refracting telescope (D = 155 mm, f = 1050 mm) and a $2k{\times}3k$ CCD Camera. The field of view is $1.0^{\circ}{\times}1.5^{\circ}$. Detection limit is about V = 13 for short-period small amplitude variables such as ${\delta}$ Scuti-type pulsating stars, and about V = 15 for long-period large amplitude variables such as eclipsing binaries and RR Lyrae stars. The instrument is designed to be remote-controlled through internet. The primary purpose of this project is to search for variable objects in bright Galactic open clusters. We present results of test observations conducted towards NGC 7092.

Development of Ignitor of Open-Type Propulsion Device for Korean Interceptor (대응탄 개방형 추진장치용 점화기개발)

  • Kwon, Soon-Kil;Kim, Chang-Kee;Yun, Sang-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1166-1170
    • /
    • 2011
  • For developing the ignition device for the interceptor of Korean active protection system, the design parameters of the ignition device which should have a short ignition delay time and sufficient energy for propellant ignition were studied. The electric primer instead of mechanical primer was adopted for deceasing delay time, and ignition code was used for decreasing the time difference of flame propagation from the flame holes. The developed ignition device showed the ignition delay time of a few ms. When the designed ignition device was applied to the open-type propulsion devices, the stable interior ballistic characteristic was showed in a firing test.

Neural Network Application to the T/L Operation for Suppression of Short Circuit Capacity (고장용량 감소를 위한 송전선 개방 운용에 신경회로망 적용 연구)

  • Lee, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.26-30
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the methods for wuppressing the short circuit capacity. This paper presents the T/L switching operation by using the Hopfield neural network(HNN). The switching of T/L can make the line powers and the bus voltages deteriorated, as well as the fault current decreased. Such an insecure state should be avoided when the T/L is operated to be open. In this studies, the inequality constraints are formulated into the objective function to be incorporated with the HNN. Test results show that the convergence characteristics of HNN lead to the adequate solution of T/L switching.

  • PDF

The Method of Determining Stress Levels Regarding the Electrical ALT through Optical Temperature Sensor

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.184-191
    • /
    • 2008
  • Electrical endurance is the critical characteristic of Magnetic contactors(MCs), which are widely used in such power equipment as elevators, cranes, and factory control rooms in order to close and open control circuits. Testing time, however, is not short in typical cases in which some method of reducing the testing period is required. This study shows the method of determining the stress level of electrical ALT(Accelerated Life Test) through optical temperature sensor and the relationship between 0.05 s and 0.1 s for on-time. The tool used for analyzing the test result is MINITAB. I will propose the method of determining the optimized stress level through optical temperature sensor, which will contribute to minimize the testing time and development period and also raise the product reliability.

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

Durability Evaluation of Cathode Open-type Proton Exchange Membrane Fuel Cells Stacks (Cathode 개방형 고분자연료전지 스택 내구성 평가)

  • Yoo, Donggeun;Kim, Hyeonsuck;Oh, Sohyeong;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Cathode open-type PEMFC (Proton Exchange Membrane Fuel Cells) stacks, which are widely used in small transport-type PEMFC, have a problem with poor durability. Through the accelerated durability test of the 13-cell PEMFC stack, we tried to find the cause of the degradation of the stack and to contribute to the improvement of the durability of the cathode open stack. A hydrogen/air boundary is formed during start-up/shut-down (SU/SD) due to the structural problem of the cathode open stack in which the cathode is open to the atmosphere and it is difficult to maintain airtightness, thereby deteriorating the cathode. In this study, it was possible to evaluate the durability in a relatively short time by reducing the 54% of the initial performance by repeating SU/SD 1,800 times on the cathode open stack. After dismantling the stack, each cell was divided into two and the performance was analyzed. Overall, the anode outlet MEA, which facilitates air inflow, showed more severe electrode deterioration than the inlet MEA, confirming that the hydrogen/air boundary formation during SU/SD is the main cause of degradation.