• Title/Summary/Keyword: One-bottle

Search Result 202, Processing Time 0.025 seconds

ENUMERATION OF THREE KINDS OF ROOTED MAPS ON THE KLEIN BOTTLE

  • Liu, Wenzhong;Liu, Yanpei
    • Journal of applied mathematics & informatics
    • /
    • v.24 no.1_2
    • /
    • pp.411-419
    • /
    • 2007
  • In this paper, $\tilde{2}$-essential rooted maps on the Klein bottle are counted and an explicit expression with the size as a parameter is given. Further, the numbers of singular maps and the maps with one vertex on the Klein bottle are derived.

A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES (제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가)

  • Kim, Hyung-Su;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

MICROLEAKAGE OF VARIOUS COMPOSITE RESIN SYSTEMS (다양한 복합레진 시스템의 변연 누출도)

  • Kim, In-Soo;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.127-133
    • /
    • 2003
  • The object of this study was to compare the microleakage between various composite resin systems of multistep, one-bottle, and self-etching systems using electrical conductivity. After making class V cavities ($4{\times}3{\times}1.5{\;}mm$ around CEJ), they were bulk filled with three kinds of resins of A3. Teeth were storaged in a saline solution for one day, after then, they were finished and polished using Sof-Lex system. Another stress of thermocycling was made for 500 times from $5^{\circ}{\;}to{\;}55^{\circ}C$ with each dwelling time of 10 seconds. Electrical conductivity (microamphere, $\mu\textrm{A}$) was checked four times: before and after cavity preparation, after filing, after thermocycling. One-way ANOVA and 95% Scheffe Post Hoc test was used for checking any statistical difference among groups. Another 95% Paired Samples T-test was also used for estimating any significant difference within group after cavity filling or thermocycling. The results were as follows: 1 Every specimen showed various range of microleakage after filing. There was, however, no difference between composite resin systems. 2. All composite resin systems showed marked increase in microleakage with a thermocycling (p<0.05), there was, however, no difference between composite resin systems. 3. Although there was no significant difference between groups (p=0.078), one-bottle and self-etching systems seemed to be unstable than multistep system. Within the limits of this study, it was concluded that much more consideration should be needed when using thermally unstable one-bottle and self-etching systems that have multi-advantages from simplified step. More studies will be needed to solve these kinds of problems.

A Study on the Router Bottle Neck for Campus Network (캠퍼스 네트워크에서의 라우터의 병목 현상에 관한 연구)

  • 고봉구;안동언정성종
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.253-256
    • /
    • 1998
  • In this paper, we discuss the CPU Utilization and bottle neck of the router on campus network. Generally, high CPU utilization does not only makes slow network speed but also frequently network disconnection. The above characteristic is based on the network with one router. In order to solve this problem, we reconstruct network configuration with two routers. Our result shows that CPU utilization of network topology with two router have good performance compared to that with one.

  • PDF

Machine-Part Cell Formation by Competitive Learning Neural Network (경쟁 학습 신경회로망을 이용한 기계-부품군 형성에 관한 연구)

  • 이성도;노상도;이교일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.432-437
    • /
    • 1997
  • In this paper, Fuzzy ART which is one of the competitive learing neural networks is applied to machine-part cell formation problem. A large matrix and varios types of machine-part incidence matrices, especially including bottle-neck machines, bottle-neck parts, parts shared by several cells, and machines shared by several cells are used to test the performannce of Fuzzy ART neural network as a cell formation algorithm. The result shows Fuzzy ART neral network can be efficiently applied to machine-part cell formation problem which are large, and/or have much imperfection as exceptions, bottle-neck machines, and bottle-neck parts.

  • PDF

SHEAR BOND STREGNTHS OF ONE-BOTTLE DENTIN ABHESIVE SYSTEMS (One-Bottle system 상아질접착제의 전단결합강도 해석)

  • Cho, Byeong-Hoon;Lim, Sung-Sam;Kwon, Hyuck-Choon;Um, Chung-Moon;Son, Ho-Hyun;Bae, Kwang-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.546-553
    • /
    • 1999
  • In Older to evaluate the effectiveness of 'One-bottle dentin adhesive system', the shear bond strengths of two fourth generation dentin adhesive systems and two One-bottle systems to the occlusal dentin of the freshly extracted third molars were measured by the regulation of the ISO TR 11405. The fourth generation dentin adhesive systems used in this study were Scotchbond Multi-Purpose Plus and All-Bond 2, and the One-bottle systems were Single Bond and One-Step. The effects of the thickness of hybrid layer and adhesive layer, the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule were analyzed as the contributing factors of the shear bond strength of dentin bonding systems from the Scanning Electron Microscopic images. The results were as follows: 1. The shear bond strengths of Scotchbond Multi-Purpose, All-Bond 2, and Single Bond were 16.98${\pm}$3.40 MPa, 15.10${\pm}$2.77 MPa and 15.05${\pm}$3.18 MPa, respectively. There were no statistical differences(p>0.05). 2. But, the shear bond strength of One-Step were significantly lower than those of the other groups (11.81${\pm}$1.95 MPa, p<0.05). 3. The thicknesses of hybrid layer and adhesive layer of One-Step were significantly thinner than those of the other groups(p<0.05). The differences of the diameter of resin tag(p=0.0685) and the ratio between the diameter of resin tag and that of dentinal tubule(p=0.2401) were not significant among all the material groups. 4. The thickness of hybrid layer and adhesive layer might be considered as contributing factors of the she at bond strengths of dentin bonding systems, but the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule might not.

  • PDF

DEVELOPMENT OF MUSHROOM SPAWN BOTTLE CUTTER-SPAWM CAKE SHREDDER

  • Choe, Kwang-Jae;Chang, Yu-Seob;Yun, Jin-Ha
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1031-1040
    • /
    • 1996
  • Spawn bottle cutting and spawn cake shredding machine has been developed to save the farm labor and operating cost for mushroom growing farmers. The prototype can cut the bottom and side of the bottle while shredding the spawn cake by one farmer. The cutting plastic shell is done by two couples of high speed disc saws that can cut cross section and lengthwise two side of the bottle, while spawn cake shredding is done by spike teethed rotating drum and wiremesh concave. The optimum speed of cutting disc saw was observed 1.700rpm both the cross cutting saw and lengthwise cutting saw in consideration of the cutting accuracy. And the location for the instalation of cross cutting disc saw was considered as around 4 mm above the table bottom , while the optimum clearance between two edges of lengthwise cutting disc saw was showed 86mm. For the sawdust spawn cake shredder , proper size of spawn sawdust granule was observed in the 15 x 15mm size withmesh concave with the shredding rum speed of 500rpm. The prototype can be reduce 73 per cent of working hours with the working cost reduction of 49 per cent compare with those of conventional operation.

  • PDF

Development of Sharpness Measuring Method for Glass Aggregate Particle made from Waste Glass Bottle

  • Sano, Shigeru;Yamada, Mari
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.76-79
    • /
    • 2001
  • In Japan in of today, there is no aspect in which the quantity of waste glass bottle discharged from ordinary homes decreases. Moreover, the kind of shape and color of the waste glass bottles are increasing little by little. In the recycling of the glass bottle, it becomes a problem that many kind of the color is abounding. It is possible to use the transparent glass bottle as raw material of the glassware. Since the reproduction of the color is difficult, the colored glass bottle is not possible to use as a raw material. Therefore, the processing of these glass bottles entirely depends on the reclamation. In Japan, the security of the new reclaimed land is very difficult for the reason of the environmental damage. Moreover, the life expectancy in many reclaimed lands is anticipated with within two years. Therefore, the development of the processing method of glass bottle other than reclamation becomes a rapid problem. At present it is examined that it is used of an aggregate of the colored pavement, as one of the application methods of colored glass bottle. The particle size of produced glass aggregate is also 5mm or less, because the thickness is 5mm or less on almost glass bottles. And almost glass particles have the sharp tip. The application as the aggregate is limited for this sharpness of the particle. This study was carried out for the purpose of the establishment of sharpness measuring method of the glass aggregate particle. It is possible that the injury degree to human in the handling is known, if showing the sharpness of the aggregate particle at the objective numerical value is possible. And the application of the glass aggregate is spread. In this research, the balloon fracture method was used for the sharpness measurement of the glass particle. This method is based on the completely new idea, and it is possible to express completely the possibility of injury to the human. It is reported with the detailed result in full paper, because this study is continuous in order to get the JIS which is industrial standard of Japan.

  • PDF

Perfume Bottles designed by Rene Lalique (르네 랄리크의 향수병 디자인 연구)

  • Kang, Yoo-Hee;Lee, Mi-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.2
    • /
    • pp.318-335
    • /
    • 2010
  • This study is to enhance the competitiveness of the domestic cosmetic industry and provide basic materials needed for a design idea by analyzing perfume bottles designed by Rene Lalique. The methods of this study are documentary research and demonstrative research. The documentary research considered the theoretical background with a focus on related domestic and international literature, previous research, and Internet materials. The demonstrative research extracted photo materials of the bottle designs of Lalique from domestic and international web sites along with literature that classified them into shapes, colors, materials, and patterns that analyzed the general characteristics and chronologic changes. The results of this study are as follows. The curve-oriented shape was common and multi-colors were used more frequently than a single color in the 1910's. Colorless-transparent glass and a flower patterns were used frequently for materials and patterns, respectively. Lalique reflects this style in his bottle designs because the Art Nouveau effect in the 1910's. In the 1920's, curved and straight shapes had a similar percentage. The use of multi-colors and one type of glass bottle increased versus the 1910's. Similar to the 1910's, a flower pattern was used most frequently. This suggests that Lalique was influenced by the established Art Nouveau and was also interested in the Art Deco style, In the 1930's, an organic curved shape was common. Unlike the 1910's and 1920's, a single color was more common than multi-colors. The one type of glass bottle and a geometric pattern were common for materials and patterns, respectively. The Art Deco style was reflected in the bottle design of Lalique in the 1930's.