• 제목/요약/키워드: One dimensional measurements

검색결과 249건 처리시간 0.027초

Fast 3-dimensional profifle measurement using slit-ray projection method

  • Ishimatsu, T.;Kawasue, K.;Kumon, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.786-790
    • /
    • 1987
  • This paper describes a systein which enables a fast 3 -dimensional profile measurement using a slit-ray projection method. One distinctive feature of this system is that a real-time video is processor is employed in order to reduce the amount of image data to be processed without eliminating essential information. Experimental results show that a calibrating method presented for the TV camera and the slit-ray projector is convenient and enables sufficient accurate measurements.

  • PDF

EFFICIENCY ANALYSIS OF A DOMAIN DECOMPOSITION METHOD FOR THE TWO-DIMENSIONAL TELEGRAPH EQUATIONS

  • Jun, Younbae
    • East Asian mathematical journal
    • /
    • 제37권3호
    • /
    • pp.295-305
    • /
    • 2021
  • In this paper, we analyze the efficiency of a domain decomposition method for the two-dimensional telegraph equations. We formulate the theoretical spectral radius of the iteration matrix generated by the domain decomposition method, because the rate of convergence of an iterative algorithm depends on the spectral radius of the iteration matrix. The theoretical spectral radius is confirmed by the experimental one using MATLAB. Speedup and operation ratio of the domain decomposition method are also compared as the two measurements of the efficiency of the method. Numerical results support the high efficiency of the domain decomposition method.

Comparison of Spectral Data of Metabolites Collected from Bruker and Varian 600 MHz Spectrometers

  • Kang, Woo-Young;Chae, Young-Kee
    • 한국자기공명학회논문지
    • /
    • 제13권1호
    • /
    • pp.7-14
    • /
    • 2009
  • The spectral data were collected from the two 600 MHz spectrometers from the two major manufacturers, Broker and Varian. The samples were prepared to create standard curves for quantitative measurements of metabolite concentrations. Instead of employing one-dimensional $^1H$ experiments, the two-dimensional $^1H-^{13}C$ HSQC experiments were performed for better separation of resonances. For some resonances, the high salt condition hindered the linear correlation between the intensity and actual metabolite concentration. Excluding overlapped ones, most resonances showed good linearity. Although the Varian spectrometer showed better linearity, both spectrometers were able to generate acceptable standard curves. From this data, we could identify resonances that could be used to better quantify the concentrations of the particular metabolites. With these standard curves, the quantitative measurements of the metabolites from the real samples will be facilitated.

비만관 개수로 유동 특성 연구 (A study on flow characteristics in a partially filled open channel)

  • 최중근;성재용;이명호;이석종
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.73-77
    • /
    • 2006
  • Flow rate measurement is one of the difficult problems in the industrial applications. Especially, flow rate in a partially filled pipeline is affected by many parameters such as water level, channel slop, etc. In the present study, prior to the development of a flowmeter, the flow characteristics has been investigated by particle image velocimetry (PIV) measurements. Three-dimensional velocity distributions were obtained from sectional measurements of velocity profiles according to the water level. As a result, it is found that there is no similarity in the velocity profile when the lateral position is changed. In addition, the maximum velocity does not always occur on the free surface. It depends on the water level. In the aspect of flow rate measurement, the previous calculus based upon point measurement techniques is proved to be inaccurate because of the lack of whole flow information.

  • PDF

Comparison of conventional lateral cephalograms with corresponding CBCT radiographs

  • Park, Chang-Seo;Park, Jae-Kyu;Kim, Huijun;Han, Sang-Sun;Jeong, Ho-Gul;Park, Hyok
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.201-205
    • /
    • 2012
  • Purpose: This study was performed to assess the compatibility of cone beam computed tomography (CBCT) synthesized cephalograms with conventional cephalograms, and to find a method for obtaining normative values for three-dimensional (3D) assessments. Materials and Methods: The sample group consisted of 10 adults with normal occlusion and well-balanced faces. They were imaged using conventional and CBCT cephalograms. The CBCT cephalograms were synthesized from the CBCT data using OnDemand 3D software. Twenty-one angular and 12 linear measurements from each imaging modality were compared and analyzed using paired-t test. Results: The linear measurements between the two imaging modalities were not statistically different (p>0.05) except for the U1 to facial plane distance. The angular measurements between the two imaging modalities were not statistically different (p>0.05) with the exception of the gonial angle, ANB difference, and facial convexity. Conclusion: Two-dimensional cephalometric norms could be readily used for 3D quantitative assessment, if corrected for lateral cephalogram distortion.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

TDOA/FDOA 동시 추정을 위한 순차적 알고리즘에 관한 연구 (A study on the sequential algorithm for simultaneous estimation of TDOA and FDOA)

  • 김창성;김중규
    • 전자공학회논문지S
    • /
    • 제35S권7호
    • /
    • pp.72-85
    • /
    • 1998
  • In this paper, we propose a new method that sequentially estimates TDOA(Time Delay Of Arrival) and FDOA(Frequency Delay Of Arrival) for extracting the information about the bearing and relative velocity of a target in passive radar or sonar arrays. The objective is to efficiently estimate the TDOA and FDOA between two sensor signal measurements, corrupted by correlated Gaussian noise sources in an unknown way. The proposed method utilizes the one dimensional slice function of the third order cumulants between the two sensor measurements, by which the effect of correlated Gaussian measurement noises can be significantly suppressed for the estimation of TDOA. Because the proposed sequential algoritjhm uses the one dimensional complex ambiguity function based on the TDOA estimate from the first step, the amount of computations needed for accurate estimationof FDOA can be dramatically reduced, especially for the cases where high frequency resolution is required. It is demonstrated that the proposed algorithm outperforms existing TDOA/FDOA estimation algorithms based on the ML(maximum likelihood) criterionandthe complex ambiguity function of the third order cumulant as well, in the MSE(mean squared error) sense and computational burden. Various numerical resutls on the detection probability, MSE and the floatingpoint computational burden are presented via Monte-Carlo simulations for different types of noises, different lengths of data, and different signal-to-noise ratios.

  • PDF

한복의 표준 치수 설정을 위한 연구 -18~26세 여성을 중심으로- (A Study on Establishment of the Standard Sizes for Hanbok - For 18~26 year old women -)

  • 박현정;이순원
    • 한국의류학회지
    • /
    • 제18권1호
    • /
    • pp.91-100
    • /
    • 1994
  • The purpose of the study is to investigate the actual conditions of ready-to-wear Hanbok and is to establish the standard sizes for the women's ready-to-wear Hanbok. Twelve ready-to-wear Hanbok shops were investigated for the actual survey. Body measurements were taken from May to June, 1990 from 329 female college students living in the Seoul and Buchon. The ages of the subjects were 18"26. Thirty seven measurements were taken from each subject and analized for the results. Data were analized by factor analysis, and regression analysis. The results were as follows ; 1. As a result of the actual survey, the situation of the quality label was not enough. The size classification was not unified, and was not trusted statistically, it cannot satisfied consumers. 2. Factor analysis identified the two dimensions of body measurements 1 one was relevant to the height measurements including stature and to the length measurements of limbs, and the other was relevant to the trunk girth measurements and the limbs girth measurements. 3. because of plane construction of Hanbok, employed in this thesis was bl-dimensional sizing system using two controle dimensions including height factor(stature) and girth factor(bust girth) . 4. The Multiple regression formula was developed for estimating secondary dimensions of Hanbok Construction, in which stature and bust girth were posited as independent variables. 5. As a results, about 88.6371 of expected distribution were covered by 9 sizes, which were used as the basis for defining sizing system for Hanbok construction.tion.

  • PDF

FLOW CHARACTERISTICS OF A TWO-DIMENSIONAL NEUTRALLY BUOYANT JET IN A MODEL SETTLING TANK

  • Kim, Young-han;Seo, Il-Won;Ahn, Jung-kyu
    • Water Engineering Research
    • /
    • 제2권1호
    • /
    • pp.21-31
    • /
    • 2001
  • In this study, laboratory experiments were performed to investigate the flow characteristics of a two-dimensional neutrally buoyant jet in the inlet region of a rectangular laboratory settling tank. Velocity measurements were made with a three-component ADV. Two types of baffles were installed in front of two-dimensional slot; a one-sided and a two-sided baffle. The flow fields from a plane jet impinging on these two types of baffles and a plane jet without a baffle showed quite different characteristics. To concentrate on investigating these flow characteristics, the effects of density currents due to temperature difference or the presence of sediments were not studied. Results of the experiments reveal that the use of the two-sided baffle results in the shortest inlet region. Also shown is that, in addition to the types of baffles, the Froude number turns out to be an important factor in the extent of the inlet region.

  • PDF

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF